Literature DB >> 8227810

Opacification and border delineation improvement in patients with suboptimal endocardial border definition in routine echocardiography: results of the Phase III Albunex Multicenter Trial.

L J Crouse1, J Cheirif, D E Hanly, J A Kisslo, A J Labovitz, J S Raichlen, R W Schutz, P M Shah, M D Smith.   

Abstract

OBJECTIVES: This study was designed to assess the safety and efficacy of intravenously administered sonicated human serum albumin for enhancing echocardiographic delineation of the left ventricular endocardium and improving assessment of wall motion in patients with incomplete depiction of noncontrast echocardiography.
BACKGROUND: Echocardiographic regional wall motion analysis is impaired by incomplete endocardial definition in as many as 10% of patients. Sonicated human serum albumin is a stable contrast material that, unlike other agents, opacifies the left ventricle when administered intravenously.
METHODS: One hundred seventy-five patients were enrolled at eight centers on the basis of incomplete echocardiographic endocardial depiction. Sonicated 5% human serum albumin, a stable preparation of air-filled microspheres (size range 1 to 10 microns), was administered intravenously in divided doses: 0.08 ml/kg body weight in all patients, followed by 0.14 and 0.08 ml/kg or a single dose of 0.22 ml/kg, depending on the result of the initial dose. Investigators and independent reviewers blinded to the protocol scored the echocardiograms for degree of left ventricular opacification and improvement of endocardial border depiction.
RESULTS: Overall, 81% of patients had at least moderate left ventricular chamber opacification with at least one contrast dose, and endocardial definition was improved in 83%. In the subgroup with inadequate left ventricular opacification from the initial dose, a second, larger dose (0.22 ml/kg) improved endocardial depiction in 64%. No significant side effects occurred.
CONCLUSIONS: In patients with incomplete echocardiographic endocardial definition, sonicated human serum albumin is a safe, effective contrast agent that, when administered intravenously, produces left ventricular chamber opacification, improves endocardial depiction and enhances regional wall motion analysis.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8227810     DOI: 10.1016/0735-1097(93)90562-f

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  31 in total

Review 1.  Section 8--clinical relevance. American Institute of Ultrasound in Medicine.

Authors: 
Journal:  J Ultrasound Med       Date:  2000-02       Impact factor: 2.153

Review 2.  Section 6--mechanical bioeffects in the presence of gas-carrier ultrasound contrast agents. American Institute of Ultrasound in Medicine.

Authors: 
Journal:  J Ultrasound Med       Date:  2000-02       Impact factor: 2.153

Review 3.  Section 7--discussion of the mechanical index and other exposure parameters. American Institute of Ultrasound in Medicine.

Authors: 
Journal:  J Ultrasound Med       Date:  2000-02       Impact factor: 2.153

Review 4.  Section 4--bioeffects in tissues with gas bodies. American Institute of Ultrasound in Medicine.

Authors: 
Journal:  J Ultrasound Med       Date:  2000-02       Impact factor: 2.153

Review 5.  Clinical and economic outcomes assessment with myocardial contrast echocardiography.

Authors:  L J Shaw; M J Monaghan; P Nihoyannopolous
Journal:  Heart       Date:  1999-11       Impact factor: 5.994

6.  An enhanced method for left ventricular volume and ejection fraction by triggered harmonic contrast echocardiography.

Authors:  K Hirooka; Y Yasumura; Y Tsujita; A Hanatani; S Nakatani; K Miyatake; M Yamagishi
Journal:  Int J Cardiovasc Imaging       Date:  2001-08       Impact factor: 2.357

7.  Sonovue improves endocardial border detection and variability in assessing wall motion score and ejection fraction during stress echocardiography.

Authors:  A S Brown; M Calachanis; C Evdoridis; J Hancock; S Wild; A Prasan; P Nihoyannopoulos; M J Monaghan
Journal:  Ir J Med Sci       Date:  2004 Jan-Mar       Impact factor: 1.568

8.  Contrast-enhanced versus non-enhanced three-dimensional echocardiography of left ventricular volumes.

Authors:  J A van der Heide; H F J Mannaerts; L Yang; G T Sieswerda; C A Visser; O Kamp
Journal:  Neth Heart J       Date:  2008-02       Impact factor: 2.380

9.  A super-resolution ultrasound method for brain vascular mapping.

Authors:  Meaghan A O'Reilly; Kullervo Hynynen
Journal:  Med Phys       Date:  2013-11       Impact factor: 4.071

Review 10.  [Assessment of systolic function in patients with poor echogenicity: echocardiographic methods].

Authors:  F Weidemann; D Liu; M Niemann; S Herrmann; H Hu; P D Gaudron; G Ertl; K Hu
Journal:  Herz       Date:  2013-08-15       Impact factor: 1.443

View more