Literature DB >> 24320408

A super-resolution ultrasound method for brain vascular mapping.

Meaghan A O'Reilly1, Kullervo Hynynen.   

Abstract

PURPOSE: High-resolution vascular imaging has not been achieved in the brain due to limitations of current clinical imaging modalities. The authors present a method for transcranial ultrasound imaging of single micrometer-size bubbles within a tube phantom.
METHODS: Emissions from single bubbles within a tube phantom were mapped through an ex vivo human skull using a sparse hemispherical receiver array and a passive beamforming algorithm. Noninvasive phase and amplitude correction techniques were applied to compensate for the aberrating effects of the skull bone. The positions of the individual bubbles were estimated beyond the diffraction limit of ultrasound to produce a super-resolution image of the tube phantom, which was compared with microcomputed tomography (micro-CT).
RESULTS: The resulting super-resolution ultrasound image is comparable to results obtained via the micro-CT for small tissue specimen imaging.
CONCLUSIONS: This method provides superior resolution to deep-tissue contrast ultrasound and has the potential to be extended to provide complete vascular network imaging in the brain.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 24320408      PMCID: PMC3799687          DOI: 10.1118/1.4823762

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  28 in total

1.  A hemisphere array for non-invasive ultrasound brain therapy and surgery.

Authors:  G T Clement; J Sun; T Giesecke; K Hynynen
Journal:  Phys Med Biol       Date:  2000-12       Impact factor: 3.609

2.  Pulse inversion imaging of liver blood flow: improved method for characterizing focal masses with microbubble contrast.

Authors:  P N Burns; S R Wilson; D H Simpson
Journal:  Invest Radiol       Date:  2000-01       Impact factor: 6.016

Review 3.  A vascular connection to Alzheimer's disease.

Authors:  J A Rhodin; T Thomas
Journal:  Microcirculation       Date:  2001-08       Impact factor: 2.628

4.  Micro-receiver guided transcranial beam steering.

Authors:  Greg T Clement; Kullervo Hynynen
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2002-04       Impact factor: 2.725

5.  Quantification of blood flow in the middle cerebral artery with phase-contrast MR imaging.

Authors:  K W Stock; S G Wetzel; P A Lyrer; E W Radü
Journal:  Eur Radiol       Date:  2000       Impact factor: 5.315

6.  Phase contrast and time-of-flight magnetic resonance angiography of the intracerebral arteries at 1.5, 3 and 7 T.

Authors:  Anna C Stamm; Chadwick L Wright; Michael V Knopp; Petra Schmalbrock; Johannes T Heverhagen
Journal:  Magn Reson Imaging       Date:  2012-12-05       Impact factor: 2.546

7.  Transcranial passive acoustic mapping with hemispherical sparse arrays using CT-based skull-specific aberration corrections: a simulation study.

Authors:  Ryan M Jones; Meaghan A O'Reilly; Kullervo Hynynen
Journal:  Phys Med Biol       Date:  2013-06-27       Impact factor: 3.609

8.  Contrast echocardiography during coronary arteriography in humans: perfusion and anatomic studies.

Authors:  S B Feinstein; R M Lang; C Dick; A Neumann; J Al-Sadir; K G Chua; J Carroll; T Feldman; K M Borow
Journal:  J Am Coll Cardiol       Date:  1988-01       Impact factor: 24.094

9.  Acoustical properties of the human skull.

Authors:  F J Fry; J E Barger
Journal:  J Acoust Soc Am       Date:  1978-05       Impact factor: 1.840

10.  Opacification and border delineation improvement in patients with suboptimal endocardial border definition in routine echocardiography: results of the Phase III Albunex Multicenter Trial.

Authors:  L J Crouse; J Cheirif; D E Hanly; J A Kisslo; A J Labovitz; J S Raichlen; R W Schutz; P M Shah; M D Smith
Journal:  J Am Coll Cardiol       Date:  1993-11-01       Impact factor: 24.094

View more
  40 in total

1.  Comparison of analytical and numerical approaches for CT-based aberration correction in transcranial passive acoustic imaging.

Authors:  Ryan M Jones; Kullervo Hynynen
Journal:  Phys Med Biol       Date:  2015-11-25       Impact factor: 3.609

Review 2.  Therapeutic potential of ultrasound microbubbles in gastrointestinal oncology: recent advances and future prospects.

Authors:  Tatiana D Khokhlova; Yasser Haider; Joo Ha Hwang
Journal:  Therap Adv Gastroenterol       Date:  2015-11       Impact factor: 4.409

3.  Transcranial cavitation detection in primates during blood-brain barrier opening--a performance assessment study.

Authors:  Shih-Ying Wu; Yao-Sheng Tung; Fabrice Marquet; Matthew Downs; Carlos Sanchez; Cherry Chen; Vincent Ferrera; Elisa Konofagou
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2014-06       Impact factor: 2.725

4.  Three-dimensional transcranial ultrasound imaging of microbubble clouds using a sparse hemispherical array.

Authors:  Meaghan A O'Reilly; Ryan M Jones; Kullervo Hynynen
Journal:  IEEE Trans Biomed Eng       Date:  2014-04       Impact factor: 4.538

5.  Experimental demonstration of passive acoustic imaging in the human skull cavity using CT-based aberration corrections.

Authors:  Ryan M Jones; Meaghan A O'Reilly; Kullervo Hynynen
Journal:  Med Phys       Date:  2015-07       Impact factor: 4.071

Review 6.  Advances in acoustic monitoring and control of focused ultrasound-mediated increases in blood-brain barrier permeability.

Authors:  Ryan M Jones; Kullervo Hynynen
Journal:  Br J Radiol       Date:  2019-02-28       Impact factor: 3.039

7.  Optimizing Sensitivity of Ultrasound Contrast-Enhanced Super-Resolution Imaging by Tailoring Size Distribution of Microbubble Contrast Agent.

Authors:  Fanglue Lin; James K Tsuruta; Juan D Rojas; Paul A Dayton
Journal:  Ultrasound Med Biol       Date:  2017-06-28       Impact factor: 2.998

Review 8.  Image-guided ultrasound phased arrays are a disruptive technology for non-invasive therapy.

Authors:  Kullervo Hynynen; Ryan M Jones
Journal:  Phys Med Biol       Date:  2016-08-05       Impact factor: 3.609

9.  Super-Resolution Ultrasound Imaging in Vivo with Transient Laser-Activated Nanodroplets.

Authors:  Geoffrey P Luke; Alexander S Hannah; Stanislav Y Emelianov
Journal:  Nano Lett       Date:  2016-04-05       Impact factor: 11.189

10.  Super-Resolution Ultrasound Imaging of Skeletal Muscle Microvascular Dysfunction in an Animal Model of Type 2 Diabetes.

Authors:  Debabrata Ghosh; Jun Peng; Katherine Brown; Shashank Sirsi; Chieko Mineo; Philip W Shaul; Kenneth Hoyt
Journal:  J Ultrasound Med       Date:  2019-01-31       Impact factor: 2.153

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.