Literature DB >> 8217457

A clinical, radiological and biomechanical study of the TARA hip prosthesis.

M C de Waal Malefijt1, R Huiskes.   

Abstract

We reviewed 60 patients with 72 TARA (total articular replacement arthroplasty) resurfacing hip prostheses. To analyse the behaviour of the femoral component a radiographic study was done and a two-dimensional finite element model was constructed. The stem of the femoral component plays a role in the load transfer mechanism. Stress shielding is seen in the proximal femur but depends on the interface conditions. When only the dome of the cup is assumed to be bonded to the bone, the stresses in the head increase dramatically and there is no more stress shielding. Five years after implantation radiographic signs of loosening of the femoral component were seen in 6.8% of the implants placed without notching in the femoral neck and in 28.6% of the components with notching (significant difference, P = 0.0005). Signs of loosening of the acetabular component were seen in 37.7% 5 years postoperatively. The cumulative survival rates of the femoral and acetabular components were 89.7% and 85.6% respectively 5 years after implantation. The overall clinical results are represented by an integration of the clinical results (Harris Hip Score System), the radiographic results and the survival analysis. This gave a success rate of only 72% 5 years after implantation.

Entities:  

Mesh:

Year:  1993        PMID: 8217457     DOI: 10.1007/bf00451878

Source DB:  PubMed          Journal:  Arch Orthop Trauma Surg        ISSN: 0936-8051            Impact factor:   3.067


  33 in total

1.  Wagner surface replacement of the hip. Three to six year follow-up.

Authors:  S O Abrahamsson; S A Ahlgren; L Stigsson
Journal:  Acta Orthop Scand       Date:  1987-04

2.  [Experience with 466 re-examined Wagner double-cup hip joint endoprostheses].

Authors:  R Ferdini; N Moos; H Brunner
Journal:  Z Orthop Ihre Grenzgeb       Date:  1986 Nov-Dec

3.  Total hip replacement of failed surface arthroplasty.

Authors:  R A Steele; D Dempster; M A Smith
Journal:  Acta Orthop Scand       Date:  1985-04

4.  Wagner surface replacement arthroplasty of the hip. Analysis of fourteen failures in forty-one hips.

Authors:  W C Head
Journal:  J Bone Joint Surg Am       Date:  1981-03       Impact factor: 5.284

5.  The results of revision of total hip arthroplasty.

Authors:  G A Hunter; R P Welsh; H U Cameron; W H Bailey
Journal:  J Bone Joint Surg Br       Date:  1979-11

6.  Loosening of the femoral component of the ICLH double cup hip prosthesis. A biomechanical investigation with reference to clinical results.

Authors:  A Schreiber; H A Jacob
Journal:  Acta Orthop Scand Suppl       Date:  1984

7.  Surface replacement arthroplasty of the hip.

Authors:  H Wagner
Journal:  Clin Orthop Relat Res       Date:  1978 Jul-Aug       Impact factor: 4.176

8.  A study of implant failure in the Wagner resurfacing arthroplasty.

Authors:  R S Bell; J Schatzker; V L Fornasier; S B Goodman
Journal:  J Bone Joint Surg Am       Date:  1985-10       Impact factor: 5.284

9.  Total hip arthroplasties in patients less than forty-five years old.

Authors:  L D Dorr; G K Takei; J P Conaty
Journal:  J Bone Joint Surg Am       Date:  1983-04       Impact factor: 5.284

10.  ICLH surface replacement of the hip. An analysis of the first 10 years.

Authors:  M A Freeman; G W Bradley
Journal:  J Bone Joint Surg Br       Date:  1983-08
View more
  6 in total

1.  Correlation between groin pain and cup design of hip-resurfacing implants: a prospective study.

Authors:  Julien Girard; Erwan Pansard; Reda Ouahes; Henri Migaud; Cyril Delay; Laurent Vasseur
Journal:  Int Orthop       Date:  2013-12-10       Impact factor: 3.075

Review 2.  [Blood flow to the femoral head and hip resurfacing arthroplasty].

Authors:  P E Beaulé; R Ganz; M Leunig
Journal:  Orthopade       Date:  2008-07       Impact factor: 1.087

3.  Hip Replacement or Hip Resurfacing with a Highly Cross-Linked Polyethylene Acetabular Bearing: A Qualitative and Quantitative Preference Study.

Authors:  James W Pritchett
Journal:  JB JS Open Access       Date:  2020-05-11

4.  [Surgical principles and clinical experiences with the DUROM hip resurfacing system using a lateral approach].

Authors:  Sascha Gravius; Torsten Mumme; Oliver Weber; Philipp Berdel; Dieter Christian Wirtz
Journal:  Oper Orthop Traumatol       Date:  2009-12       Impact factor: 1.154

5.  Is it Time for Cementless Hip Resurfacing?

Authors:  Julien Girard
Journal:  HSS J       Date:  2012-09-13

6.  Survivorship of standard versus modified posterior surgical approaches in metal-on-metal hip resurfacing.

Authors:  K M Takamura; P Maher; T Nath; E P Su
Journal:  Bone Joint Res       Date:  2014-05       Impact factor: 5.853

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.