Literature DB >> 8217439

Magnetic resonance imaging of coronary arteries: technique and preliminary results.

D J Pennell1, J Keegan, D N Firmin, P D Gatehouse, S R Underwood, D B Longmore.   

Abstract

BACKGROUND: Coronary artery imaging is an important investigation for the management of coronary artery disease. The only reliable technique presently available, x ray contrast angiography, is invasive and is associated with a small morbidity and mortality. Alternative non-invasive imaging would be useful, but the small calibre and tortuosity of the coronary vessels, and cardiac and respiratory motion create formidable imaging problems.
OBJECTIVE: The development of rapid magnetic resonance imaging of the coronary arteries. PATIENTS: 21 healthy controls and five patients with coronary artery disease established by x ray contrast angiography, of whom two had undergone bypass grafting.
METHODS: Magnetic resonance imaging was performed with gradient echoes and a segmented k-space technique, such that a complete image was acquired in 16 cardiac cycles during a breathhold. The signal from fat was suppressed and images were acquired in late diastole to reduce artefact from cardiac motion. An imaging strategy was developed for the proximal arteries, including longitudinal imaging from oblique planes defined according to the origins and the continuation of the arteries in the atrioventricular grooves or interventricular sulcus.
RESULTS: Of the 26 subjects studied, 22 were imaged successfully. Identification of the artery was possible for the left main stem, left anterior descending, right coronary, and left circumflex arteries respectively in 95%, 91%, 95%, and 76%. The arterial diameter at the origin could be measured in 77%, 77%, 81%, and 63%. The mean (SD) arterial diameter in each case (4.8 (0.8), 3.7 (0.5), 3.9 (0.9), and 2.9 (0.6) mm) was not significantly different from reference values. The mean length of artery visualised was 10.4 (5.2), 46.7 (22.8), 53.7 (27.9), and 26.3 (17.5) mm. In 12 healthy men the total coronary area was 30.9 (9.2) mm2 and the ratio compared with body surface area was 16.4 (4.4) mm2m2 (both p = NS compared with reference values). In seven patients in whom x ray contrast coronary angiography was available, the proximal arterial diameter was 3.9 (1.1) mm measured by magnetic resonance and 3.7 (1.0) mm by x ray contrast angiography (p = NS). The mean difference between the measurements was 0.2 (0.5) mm, and the coefficient of variation was 13.7%. All five occluded coronary arteries were identified, as were all three vein grafts. In two patients insertion of the graft into the native arteries was identified.
CONCLUSIONS: Magnetic resonance coronary angiography is feasible. Good results were obtained by a breath-hold, fat suppression technique, gated to late diastole. Arterial occlusions and vein grafts were readily identified. Further studies are required to establish its value in the detection of coronary stenosis and to develop the measurement of coronary flow velocity which could be used to quantify the severity of the stenosis.

Entities:  

Mesh:

Year:  1993        PMID: 8217439      PMCID: PMC1025326          DOI: 10.1136/hrt.70.4.315

Source DB:  PubMed          Journal:  Br Heart J        ISSN: 0007-0769


  35 in total

1.  Cine coronary arteriography.

Authors:  F M SONES; E K SHIREY
Journal:  Mod Concepts Cardiovasc Dis       Date:  1962-07

2.  Interobserver variability in coronary angiography.

Authors:  L M Zir; S W Miller; R E Dinsmore; J P Gilbert; J W Harthorne
Journal:  Circulation       Date:  1976-04       Impact factor: 29.690

3.  Selective coronary arteriography. I. A percutaneous transfemoral technic.

Authors:  M P Judkins
Journal:  Radiology       Date:  1967-11       Impact factor: 11.105

4.  Complications of coronary arteriography from the Collaborative Study of Coronary Artery Surgery (CASS).

Authors:  K Davis; J W Kennedy; H G Kemp; M P Judkins; A J Gosselin; T Killip
Journal:  Circulation       Date:  1979-06       Impact factor: 29.690

5.  MR imaging of the aortic root and proximal coronary arteries.

Authors:  S Paulin; G K von Schulthess; E Fossel; H P Krayenbuehl
Journal:  AJR Am J Roentgenol       Date:  1987-04       Impact factor: 3.959

6.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

Review 7.  Nuclear magnetic resonance imaging of the heart. Current status and future prospects.

Authors:  R E Steiner; G M Bydder; A Selwyn; J Deanfield; D B Longmore; R H Klipsten; D Firmin
Journal:  Br Heart J       Date:  1983-09

8.  Measurement of flow with NMR imaging using a gradient pulse and phase difference technique.

Authors:  D J Bryant; J A Payne; D N Firmin; D B Longmore
Journal:  J Comput Assist Tomogr       Date:  1984-08       Impact factor: 1.826

9.  Preliminary experimental results in humans and animals with a superconducting, whole-body, nuclear magnetic resonance scanner.

Authors:  R J Alfidi; J R Haaga; S J El-Yousef; P J Bryan; B D Fletcher; J P LiPuma; S C Morrison; B Kaufman; J B Richey; W S Hinshaw; D M Kramer; H N Yeung; A M Cohen; H E Butler; A E Ament; J M Lieberman
Journal:  Radiology       Date:  1982-04       Impact factor: 11.105

10.  Mortality related to cardiac catheterization and angiography.

Authors:  J W Kennedy; W A Baxley; I L Bunnel; G G Gensini; J V Messer; J G Mudd; T J Noto; S Paulin; A D Pichard; W C Sheldon; M Cohen
Journal:  Cathet Cardiovasc Diagn       Date:  1982
View more
  14 in total

1.  Magnetic resonance imaging of the coronary arteries: clinical results from three dimensional evaluation of a respiratory gated technique.

Authors:  R J van Geuns; H G de Bruin; B J Rensing; P A Wielopolski; M D Hulshoff; P M van Ooijen; M Oudkerk; P J de Feyter
Journal:  Heart       Date:  1999-10       Impact factor: 5.994

2.  Usefulness of coronary MR angiography prior to angioplasty.

Authors:  A J Duerinckx; D Laughrun; B S Lewis
Journal:  Int J Card Imaging       Date:  1999-12

3.  The intravascular contrast agent Clariscan (NC 100150 injection) for 3D MR coronary angiography in patients with coronary artery disease.

Authors:  C Klein; E Nagel; B Schnackenburg; A Bornstedt; S Schalla; V Hoffmann; A Lehning; E Fleck
Journal:  MAGMA       Date:  2000-11       Impact factor: 2.310

4.  Volume coronary angiography using targeted scans (VCATS): a new strategy in MR coronary angiography.

Authors:  R J van Geuns; P A Wielopolski; A J Wardeh; H G de Bruin; M Oudkerk; P J de Feyter
Journal:  Int J Cardiovasc Imaging       Date:  2001-10       Impact factor: 2.357

Review 5.  Ischemic heart disease: value of MR techniques.

Authors:  E E van der Wall; F P van Rugge; H W Vliegen; J H Reiber; A de Roos; A V Bruschke
Journal:  Int J Card Imaging       Date:  1997-06

6.  3D motion adapted gating (3D MAG): a new navigator technique for accelerated acquisition of free breathing navigator gated 3D coronary MR-angiography.

Authors:  M Hackenbroch; K Nehrke; J Gieseke; C Meyer; K Tiemann; H Litt; O Dewald; C P Naehle; H Schild; T Sommer
Journal:  Eur Radiol       Date:  2005-04-07       Impact factor: 5.315

7.  Spatial factors for quantifying constant flow velocity in a small tube phantom: comparison of phase-contrast cine-magnetic resonance imaging and the intraluminal Doppler guidewire method.

Authors:  Haruhiko Machida; Yoshiaki Komori; Eiko Ueno; Yun Shen; Masami Hirata; Shinya Kojima; Satoru Morita; Munekuni Sato; Takeshi Okazaki
Journal:  Jpn J Radiol       Date:  2009-11-27       Impact factor: 2.374

8.  Two-dimensional coronary MRA: limitations and artifacts.

Authors:  A J Duerinckx; D P Atkinson; J Mintorovitch; O P Simonetti; M K Vrman
Journal:  Eur Radiol       Date:  1996       Impact factor: 5.315

9.  Assessment of magnetic resonance velocity mapping of global ventricular function during dobutamine infusion in coronary artery disease.

Authors:  D J Pennell; D N Firmin; P Burger; G Z Yang; C C Manzara; P J Ell; R H Swanton; J M Walker; S R Underwood; D B Longmore
Journal:  Br Heart J       Date:  1995-08

10.  Rapid-motion-perception based cardiac navigators: using the high flow blood volume as a marker for the position of the heart.

Authors:  Vinay M Pai; Han Wen
Journal:  J Cardiovasc Magn Reson       Date:  2003       Impact factor: 5.364

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.