Literature DB >> 14664131

Rapid-motion-perception based cardiac navigators: using the high flow blood volume as a marker for the position of the heart.

Vinay M Pai1, Han Wen.   

Abstract

Navigators have been developed as one of the many approaches to reducing motion artifacts due to respiration. A typical navigator approach applies a pencil-beam style profile crossing the diaphragm to track the superior-inferior (SI) motion of the diaphragm, and subsequently applying correlations to determine the heart location. This approach necessitates a priori knowledge of the correlation coefficients between heart and diaphragm motion, a variable parameter among patients. This paper presents an alternative navigator method based on Rapid Motion Perception (RaMP). This method acquires profiles of the ventricular blood volume based on its high flow velocity. The position of the blood volume is a direct representation of the position of the heart. This method allows cardiac navigation in two orthogonal directions simultaneously, eliminates the need to obtain correlations to the diaphragm motion, and increases tracking reliability for individual patients. A prospective version of RaMP navigators has been implemented on a clinical 1.5 T scanner, and preliminary tests on human volunteers show that this method can successfully track the heart position over the entire respiratory period. This navigation scheme is tested for predicting superior-inferior and anterior-posterior (AP) motion of the heart for breath-hold and free breathing conditions. Bland-Altman plots comparing the motion predicted by the navigators and that computed from single-shot images immediately following the navigators, show that the accuracy of this method is +/- 1.43 mm in the SI direction and +/- 0.84 mm in the AP direction. The RaMP navigator is suited for real-time tracking of the bulk translational motion of the heart.

Entities:  

Mesh:

Year:  2003        PMID: 14664131      PMCID: PMC2886515          DOI: 10.1081/jcmr-120025228

Source DB:  PubMed          Journal:  J Cardiovasc Magn Reson        ISSN: 1097-6647            Impact factor:   5.364


  22 in total

1.  Optimization of realtime adaptive navigator correction for 3D magnetic resonance coronary angiography.

Authors:  E Nagel; A Bornstedt; B Schnackenburg; J Hug; H Oswald; E Fleck
Journal:  Magn Reson Med       Date:  1999-08       Impact factor: 4.668

2.  Relationship between motion of coronary arteries and diaphragm during free breathing: lessons from real-time MR imaging.

Authors:  P G Danias; M Stuber; R M Botnar; K V Kissinger; R R Edelman; W J Manning
Journal:  AJR Am J Roentgenol       Date:  1999-04       Impact factor: 3.959

Review 3.  Measuring agreement in method comparison studies.

Authors:  J M Bland; D G Altman
Journal:  Stat Methods Med Res       Date:  1999-06       Impact factor: 3.021

4.  Submillimeter three-dimensional coronary MR angiography with real-time navigator correction: comparison of navigator locations.

Authors:  M Stuber; R M Botnar; P G Danias; K V Kissinger; W J Manning
Journal:  Radiology       Date:  1999-08       Impact factor: 11.105

5.  Coronary artery motion with the respiratory cycle during breath-holding and free-breathing: implications for slice-followed coronary artery imaging.

Authors:  Jennifer Keegan; Peter Gatehouse; Guang-Zhong Yang; David Firmin
Journal:  Magn Reson Med       Date:  2002-03       Impact factor: 4.668

6.  FLASH imaging: rapid NMR imaging using low flip-angle pulses. 1986.

Authors:  A Haase; J Frahm; D Matthaei; W Hänicke; K-D Merboldt
Journal:  J Magn Reson       Date:  2011-12       Impact factor: 2.229

7.  Protocol for two-dimensional magnetic resonance coronary angiography studied in three-dimensional magnetic resonance data sets.

Authors:  J C Post; A C van Rossum; M B Hofman; J Valk; C A Visser
Journal:  Am Heart J       Date:  1995-07       Impact factor: 4.749

8.  A preliminary report comparing magnetic resonance coronary angiography with conventional angiography.

Authors:  W J Manning; W Li; R R Edelman
Journal:  N Engl J Med       Date:  1993-03-25       Impact factor: 91.245

9.  Navigator-echo-based real-time respiratory gating and triggering for reduction of respiration effects in three-dimensional coronary MR angiography.

Authors:  Y Wang; P J Rossman; R C Grimm; S J Riederer; R L Ehman
Journal:  Radiology       Date:  1996-01       Impact factor: 11.105

Review 10.  Cardiac MR imaging: principles and techniques.

Authors:  E M Haacke; D Li; S Kaushikkar
Journal:  Top Magn Reson Imaging       Date:  1995
View more