Literature DB >> 8201558

Lens refilling and endocapsular polymerization of an injectable intraocular lens: in vitro and in vivo study of potential risks and benefits.

H J Hettlich1, K Lucke, M N Asiyo-Vogel, M Schulte, A Vogel.   

Abstract

Endocapsular cataract removal and injection of a liquid artificial lens has several advantages, including restitution of accommodation, small corneoscleral incision, a more physiological position of the intraocular lens, and a reduced rate of secondary opacification. Our technique consists of bimanual phacofragmentation followed by injection of a fluid monomeric material that can be polymerized inside the capsular bag by short light exposure. Our study assessed the potential risks of the technique (e.g., heat damage to ocular tissue, light damage to the retina) and investigated the technique in vivo. We performed in vitro experiments on porcine cadaver eyes and an in vivo study on 15 rabbits. After a clinical follow-up of at least 12 weeks, the eyes were investigated histopathologically. During the polymerization process, the highest temperature measured at the posterior lens capsule was 45.1 degrees Celsius for a few seconds. The measured irradiance (0.065 watts per cm2) and the risk of photochemical damage to the retina during 20 seconds of polymerization were comparable to that caused by 1.5 minutes of standard coaxial illumination with the operating microscope. In vivo there were no serious inflammatory reactions except in four cases in which there had been intraoperative problems. The rate of secondary opacification appeared less than in conventional intraocular lens implantation in rabbits, especially when the capsule refilled completely. Retinal damage could not be detected histopathologically. In conclusion, refilling techniques may be successful once appropriate refilling materials become available.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 8201558     DOI: 10.1016/s0886-3350(13)80149-6

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  11 in total

1.  [History of the development of intraocular lenses].

Authors:  G U Auffarth; D J Apple
Journal:  Ophthalmologe       Date:  2001-11       Impact factor: 1.059

2.  In vitro and in vivo study of lens refilling with poloxamer hydrogel.

Authors:  Y K Han; J W Kwon; J S Kim; C-S Cho; W R Wee; J H Lee
Journal:  Br J Ophthalmol       Date:  2003-11       Impact factor: 4.638

Review 3.  Accommodating intraocular lenses: a critical review of present and future concepts.

Authors:  R Menapace; O Findl; K Kriechbaum; Ch Leydolt-Koeppl
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2006-08-30       Impact factor: 3.117

4.  Three-dimensional ultrasound biomicroscopy, environmental and conventional scanning electron microscopy investigations of the human zonula ciliaris for numerical modelling of accommodation.

Authors:  Oliver Stachs; Heiner Martin; Detlef Behrend; Klaus-Peter Schmitz; Rudolf Guthoff
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2005-10-05       Impact factor: 3.117

5.  [Three-dimensional ultrasound biomicroscopic examinations for haptic differentiation of potentially accommodative intraocular lenses].

Authors:  O Stachs; H Schneider; J Stave; R Beck; R F Guthoff
Journal:  Ophthalmologe       Date:  2005-03       Impact factor: 1.059

6.  Optical principles, biomechanics, and initial clinical performance of a dual-optic accommodating intraocular lens (an American Ophthalmological Society thesis).

Authors:  Stephen D McLeod
Journal:  Trans Am Ophthalmol Soc       Date:  2006

Review 7.  [Accommodation and presbyopia : part 2: surgical procedures for the correction of presbyopia].

Authors:  M Baumeister; T Kohnen
Journal:  Ophthalmologe       Date:  2008-11       Impact factor: 1.059

8.  Role of the lens capsule on the mechanical accommodative response in a lens stretcher.

Authors:  Noël M Ziebarth; David Borja; Esdras Arrieta; Mohamed Aly; Fabrice Manns; Isabelle Dortonne; Derek Nankivil; Rakhi Jain; Jean-Marie Parel
Journal:  Invest Ophthalmol Vis Sci       Date:  2008-05-30       Impact factor: 4.799

9.  [Lens refilling].

Authors:  H-J Hettlich
Journal:  Ophthalmologe       Date:  2010-05       Impact factor: 1.059

10.  Accommodation amplitudes after an accommodating intraocular lens refilling procedure: in vivo update.

Authors:  Okihiro Nishi; Yutaro Nishi; Shiao Chang; Kayo Nishi
Journal:  J Cataract Refract Surg       Date:  2014-02       Impact factor: 3.351

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.