Literature DB >> 15503052

[Three-dimensional ultrasound biomicroscopic examinations for haptic differentiation of potentially accommodative intraocular lenses].

O Stachs1, H Schneider, J Stave, R Beck, R F Guthoff.   

Abstract

PURPOSE: The principal ability of potentially accommodative IOLs is based on an axial shift of the IOL optics induced by the ciliary body action in interaction with a reversible change in haptic angulation. The aim of this study was to investigate the accommodative performance of this new IOL generation.
METHOD: The authors have designed a test device to study IOL performance experimentally. These results were extrapolated to the in vivo situation in patients with accommodative implants.
RESULTS: The 3D high-resolution presentation of the anterior segment of the eye allows a separation of the IOL haptic elements. In vitro and in the selected in vivo cases a change in haptic angulation <10 degrees in combination with a maximal IOL shift of 0.5 mm was found.
CONCLUSIONS: The simulation model used in combination with 3D ultrasound biomicroscopy provides information about the potential of accommodative IOL designs. Conclusions corresponding to changes in haptic angulation during accommodation can be drawn and applied to the in vivo situation.

Entities:  

Mesh:

Year:  2005        PMID: 15503052     DOI: 10.1007/s00347-004-1122-1

Source DB:  PubMed          Journal:  Ophthalmologe        ISSN: 0941-293X            Impact factor:   1.059


  20 in total

1.  Age-related changes in human ciliary muscle and lens: a magnetic resonance imaging study.

Authors:  S A Strenk; J L Semmlow; L M Strenk; P Munoz; J Gronlund-Jacob; J K DeMarco
Journal:  Invest Ophthalmol Vis Sci       Date:  1999-05       Impact factor: 4.799

2.  Measurement of accommodation after implantation of an accommodating posterior chamber intraocular lens.

Authors:  Achim Langenbucher; Stefan Huber; Nhung X Nguyen; Berthold Seitz; Gabriele C Gusek-Schneider; Michael Küchle
Journal:  J Cataract Refract Surg       Date:  2003-04       Impact factor: 3.351

3.  Monitoring accommodative ciliary muscle function using three-dimensional ultrasound.

Authors:  Oliver Stachs; Heiner Martin; Alexander Kirchhoff; Joachim Stave; Thom Terwee; Rudolf Guthoff
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2002-10-09       Impact factor: 3.117

4.  Apparent accommodation in pseudophakic eyes.

Authors:  G Ravalico; F Baccara
Journal:  Acta Ophthalmol (Copenh)       Date:  1990-10

5.  Pseudophakic accommodation? A study of the stability of capsular bag supported, one piece, rigid tripod, or soft flexible implants.

Authors:  S J Hardman Lea; M P Rubinstein; M P Snead; S M Haworth
Journal:  Br J Ophthalmol       Date:  1990-01       Impact factor: 4.638

6.  Pseudoaccommodation: BioComFold versus a foldable silicone intraocular lens.

Authors:  J M Legeais; L Werner; L Werner; A Abenhaim; G Renard
Journal:  J Cataract Refract Surg       Date:  1999-02       Impact factor: 3.351

7.  Experience with an accommodating IOL.

Authors:  J S Cumming; J Kammann
Journal:  J Cataract Refract Surg       Date:  1996-10       Impact factor: 3.351

8.  Intraocular lens movement caused by ciliary muscle contraction.

Authors:  Oliver Findl; Barbara Kiss; Vanessa Petternel; Rupert Menapace; Michael Georgopoulos; Georg Rainer; Wolfgang Drexler
Journal:  J Cataract Refract Surg       Date:  2003-04       Impact factor: 3.351

9.  Phaco-Ersatz: cataract surgery designed to preserve accommodation.

Authors:  J M Parel; H Gelender; W F Trefers; E W Norton
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1986       Impact factor: 3.117

10.  Apparent accommodation in pseudophakic eyes after implantation of posterior chamber intraocular lenses: optical analysis.

Authors:  M Nakazawa; K Ohtsuki
Journal:  Invest Ophthalmol Vis Sci       Date:  1984-12       Impact factor: 4.799

View more
  1 in total

1.  Micro-CT in ophthalmology: ex vivo preparation and contrasting methods for detailed 3D-visualization of eye anatomy with special emphasis on critical point drying.

Authors:  Jens Runge; Thomas Stahnke; Rudolf F Guthoff; Andreas Wree; Jonas Keiler
Journal:  Quant Imaging Med Surg       Date:  2022-09
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.