Digital and brachial artery blood pressure measurements during peripheral, cold-induced vasoconstriction.

M A Stroud1, D P James, D Railton, P J Sowood.   

Abstract

Measurements of digital artery blood pressure made using an automated photoplethysmographic method (Finapres), in the middle finger of the left hands of nine male subjects, were compared with pressure measures in the right brachial artery using a method relying on the abolition of Karotkoff sounds during occlusion of the upper arm by a pressure cuff (Dinamap), during a 40-min immersion of the hand in cold (4 degrees C) and thermoneutral (32 degrees C) water. Blood flow in the left index finger was assessed and temperatures of the left and right ring fingers were also measured. Before immersion, systolic pressures in the digital artery were higher than systolic pressures in the brachial artery (P < 0.05), whereas the corresponding diastolic measurements were similar. However, both systolic (P < 0.01) and diastolic (P < 0.05) digital artery measurements increased with time. During cold immersion both systolic and diastolic pressures increased at both sites (P < 0.01), although the digital artery systolic readings rose sharply and then declined, whereas the brachial artery readings were stable. The cold-immersed digital artery diastolic measurements were greater than the brachial artery measurements (P < 0.01) and showed a continuation of the upward trend noted prior to immersion (P < 0.01). Thermoneutral diastolic digital artery measurements also showed this continued trend (P < 0.001). Some individual photoplethysmograph assessments of index finger blood flows showed intermittent vasodilatation, but cold immersion caused a decline in mean flow to 22% of pre-immersion value at 15 min, followed by an increase to 40%.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1994        PMID: 8194542     DOI: 10.1007/bf00244026

Source DB:  PubMed          Journal:  Eur J Appl Physiol Occup Physiol        ISSN: 0301-5548


  6 in total

1.  Comparison of simultaneously recorded central and peripheral arterial pressure pulses during rest, exercise and tilted position in man.

Authors:  E J KROEKER; E H WOOD
Journal:  Circ Res       Date:  1955-11       Impact factor: 17.367

2.  On the reliability of the Penaz cuff during systemic and local fingertip vasodilatation at rest and in exercise.

Authors:  W Hildebrandt; H Schütze; J Stegemann
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1991

3.  Comparison of finger and intra-arterial blood pressure monitoring at rest and during laboratory testing.

Authors:  G Parati; R Casadei; A Groppelli; M Di Rienzo; G Mancia
Journal:  Hypertension       Date:  1989-06       Impact factor: 10.190

4.  Evaluation of the Penàz servo-plethysmo-manometer for the continuous, non-invasive measurement of finger blood pressure.

Authors:  G P Molhoek; K H Wesseling; J J Settels; E van Vollenhoven; H W Weeda; B de Wit; A C Arntzenius
Journal:  Basic Res Cardiol       Date:  1984 Sep-Oct       Impact factor: 17.165

5.  Effects of peripheral vasoconstriction on the blood pressure in the finger, measured continuously by a new noninvasive method (the Finapres).

Authors:  J C Dorlas; J A Nijboer; W T Butijn; G M van der Hoeven; J J Settels; K H Wesseling
Journal:  Anesthesiology       Date:  1985-03       Impact factor: 7.892

6.  Local reflex in microcirculation in human skeletal muscle.

Authors:  O Henriksen; P Sejrsen
Journal:  Acta Physiol Scand       Date:  1977-01
  6 in total
  1 in total

1.  An Estimation Method of Continuous Non-Invasive Arterial Blood Pressure Waveform Using Photoplethysmography: A U-Net Architecture-Based Approach.

Authors:  Tasbiraha Athaya; Sunwoong Choi
Journal:  Sensors (Basel)       Date:  2021-03-07       Impact factor: 3.576

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.