The risk of small St. Jude aortic valve prostheses.

J M Kratz1, R M Sade, F A Crawford, A J Crumbley, M R Stroud.   

Abstract

We reviewed our 12-year experience with 254 adult patients who had St. Jude valves in the aortic position and used multivariate analysis to examine risk factors possibly affecting long-term morbidity and mortality. Nineteen-millimeter or 21-mm valves were implanted in 115 patients. Poor preoperative congestive heart failure status was associated with persistent congestive heart failure on late follow-up. Preoperative congestive heart failure and coronary artery disease were the only predictors of overall late death. Late deaths associated with heart failure and late sudden deaths were examined separately. Preoperative degree of heart failure was the only predictor of late death with associated heart failure. The implantation of a 19- or 21-mm valve in patients with a body surface area greater than 1.9 m2 somewhat increased the risk of late sudden death. In patients with a body surface area greater than 1.9 m2 and with a 19-mm or 21-mm annulus, consideration should be given to using a high-performance St. Jude valve or performing an annulus-enlarging procedure if this can be done with negligible morbidity.

Entities:  

Mesh:

Year:  1994        PMID: 8179372     DOI: 10.1016/0003-4975(94)91339-0

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  6 in total

1.  Left ventricular mass index reduction early after an isolated aortic valve replacement with St. Jude Medical 19A-HP.

Authors:  Shin Uchikawa; Shigeyuki Aomi; Akihiko Kawai; Kenji Yamazaki; Yasuko Tomizawa; Hiroshi Nishida; Masahiro Endo; Hitoshi Koyanagi
Journal:  Jpn J Thorac Cardiovasc Surg       Date:  2003-08

2.  [Hemodynamic evaluations of patients with small aortic annulus with St. Jude Medical prosthetic heart valve].

Authors:  T Shimabukuro; Y Takeuchi; A Gomi; H Nakatani; Y Suda; K Kono; N Nagano
Journal:  Jpn J Thorac Cardiovasc Surg       Date:  1998-12

3.  Mid-term results of small-sized St. Jude Medical Regent prosthetic valves (21 mm or less) for small aortic annulus.

Authors:  Hiroki Mizoguchi; Masayuki Sakaki; Kazushige Inoue; Takashi Iwata; Keikou Tei; Takuya Miura
Journal:  Heart Vessels       Date:  2012-11-17       Impact factor: 2.037

4.  Haemodynamic performance of aortic pericardial bioprostheses and bileaflet prostheses at rest and during exercise: implications for the surgical management of patients with small aortic roots.

Authors:  J R González-Juanatey; M V Fernández; F G Sampedro; J M García-Acuña; J B García-Bengoechea; A A Cendon; M G de La Peña
Journal:  Heart       Date:  1999-08       Impact factor: 5.994

5.  Is the threshold for postoperative prosthesis-patient mismatch the same for all prostheses?

Authors:  Homare Okamura; Atsushi Yamaguchi; Hideki Morita; Kazuhiro Naito; Koichi Yuri; Hideo Adachi
Journal:  Surg Today       Date:  2012-08-25       Impact factor: 2.549

6.  Early evaluation of the aortic root after Nicks' procedure.

Authors:  Ujjwal Kumar Chowdhury; Sukhjeet Singh; Niwin George; Suruchi Hasija; Lakshmikumari Sankhyan; Niraj Nirmal Pandey; Sanjoy Sengupta; Mani Kalaivani
Journal:  JTCVS Tech       Date:  2020-08-13
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.