Is the threshold for postoperative prosthesis-patient mismatch the same for all prostheses?

Homare Okamura1, Atsushi Yamaguchi, Hideki Morita, Kazuhiro Naito, Koichi Yuri, Hideo Adachi.   

Abstract

PURPOSE: The effective orifice area index (EOAI) is used to define the prosthesis-patient mismatch (PPM) after aortic valve replacement (AVR). However, few studies have so far evaluated whether the cutoff value for PPM varies across prostheses. This study assessed the hemodynamics in patients given a mechanical valve and then re-evaluated the validity of the commonly accepted threshold.
METHODS: The subjects included 329 patients that underwent AVR with a St. Jude Medical Regent valve. The transvalvular pressure gradient and EOAI were determined echocardiographically, and the commonly accepted threshold was analyzed in relation to survival.
RESULTS: The mechanical valves very often yielded a postoperative transvalvular pressure gradient >10 mmHg, and thus, clinically significant residual pressure, regardless of the EOAI. The slope of the curve describing the relationship between the transvalvular pressure gradient and EOAI was gentler than that reported for bioprosthetic valves, for which the pressure gradient rises sharply at EOAI <0.85 cm(2)/m(2). The commonly defined PPM did not affect the long-term survival or regression of the left ventricular mass index.
CONCLUSIONS: The relationship between the transvalvular pressure gradient and the EOAI in patients given a mechanical prosthesis differed from the reference standard. These data suggest the need to reconsider the appropriate cutoff value for PPM in relation to different prostheses.

Entities:  

Mesh:

Year:  2012        PMID: 22922836     DOI: 10.1007/s00595-012-0311-9

Source DB:  PubMed          Journal:  Surg Today        ISSN: 0941-1291            Impact factor:   2.549


  16 in total

Review 1.  Hemodynamic and clinical impact of prosthesis-patient mismatch in the aortic valve position and its prevention.

Authors:  P Pibarot; J G Dumesnil
Journal:  J Am Coll Cardiol       Date:  2000-10       Impact factor: 24.094

2.  Prediction of postoperative exercise tolerance after aortic valve replacement.

Authors:  K Hirooka; K Kawazoe; Y Kosakai; Y Sasako; K Eishi; Y Kito; N Nakanishi; T Yoshioka; Y Kawashima
Journal:  Ann Thorac Surg       Date:  1994-12       Impact factor: 4.330

3.  Aortic valve replacement: is valve size important?

Authors:  B Medalion; E H Blackstone; B W Lytle; J White; J H Arnold; D M Cosgrove
Journal:  J Thorac Cardiovasc Surg       Date:  2000-05       Impact factor: 5.209

4.  Influence of the size of aortic valve prostheses on hemodynamics and change in left ventricular mass: implications for the surgical management of aortic stenosis.

Authors:  J R González-Juanatey; J M García-Acuña; M Vega Fernandez; A Amaro Cendón; V Castelo Fuentes; J B García-Bengoechea; M G de la Peña
Journal:  J Thorac Cardiovasc Surg       Date:  1996-08       Impact factor: 5.209

5.  Comparative rest and exercise hemodynamics of 23-mm stentless versus 23-mm stented aortic bioprostheses.

Authors:  R Fries; O Wendler; H Schieffer; H J Schäfers
Journal:  Ann Thorac Surg       Date:  2000-03       Impact factor: 4.330

6.  Reconsideration of patient-prosthesis mismatch definition from the valve indexed effective orifice area.

Authors:  Yoshimasa Sakamoto; Michio Yoshitake; Hirokuni Naganuma; Noriyasu Kawada; Katsushi Kinouchi; Kazuhiro Hashimoto
Journal:  Ann Thorac Surg       Date:  2010-06       Impact factor: 4.330

7.  POINT: Prosthesis-patient mismatch does not affect survival for patients greater than 70 years of age undergoing bioprosthetic aortic valve replacement.

Authors:  Marc R Moon; Jennifer S Lawton; Nader Moazami; Nabil A Munfakh; Michael K Pasque; Ralph J Damiano
Journal:  J Thorac Cardiovasc Surg       Date:  2008-12-19       Impact factor: 5.209

Review 8.  The problem of valve prosthesis-patient mismatch.

Authors:  S H Rahimtoola
Journal:  Circulation       Date:  1978-07       Impact factor: 29.690

9.  One year hemodynamic performance of the Perimount Magna pericardial xenograft and the Medtronic Mosaic bioprosthesis in the aortic position: a prospective randomized study.

Authors:  María José Dalmau; José María González-Santos; Javier López-Rodríguez; María Bueno; Antonio Arribas; Félix Nieto
Journal:  Interact Cardiovasc Thorac Surg       Date:  2007-03-28

10.  Impact of prosthesis-patient mismatch on long-term survival after aortic valve replacement: influence of age, obesity, and left ventricular dysfunction.

Authors:  Dania Mohty; Jean G Dumesnil; Najmeddine Echahidi; Patrick Mathieu; François Dagenais; Pierre Voisine; Philippe Pibarot
Journal:  J Am Coll Cardiol       Date:  2009-01-06       Impact factor: 24.094

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.