Literature DB >> 8165612

Are capillary whole blood coagulation monitors suitable for the control of oral anticoagulant treatment by the international normalized ratio?

A Tripodi1, A A Arbini, V Chantarangkul, D Bettega, P M Mannucci.   

Abstract

The 512 Coagulation Monitor is a portable coagulation photometer that uses disposable cartridges containing a lyophilized rabbit brain thromboplastin to measure the PT for capillary whole blood. It has been proposed as a suitable system for patient self monitoring at home, but its performance has never been thoroughly assessed for results expressed as International Normalized Ratio (INR). In particular, there is no available information about the adequacy of the WHO calibration model with the Monitor. The aims of the study were to determine the International Sensitivity Index (ISI) against the secondary International Reference Preparation for rabbit thromboplastin and to assess the precision of the INR. The study demonstrates that the Monitor can be calibrated with the WHO model, because log-transformed PTs for patients stabilized on oral anticoagulants and normal individuals are linearly related and because the same orthogonal regression line describes patient and normal data points adequately. However, the ISI calculated in this study (2.715) is higher than that adopted by the manufacturer (2.036). The between-assay reproducibility of the Monitor is acceptable (CV = 9.7%) with results expressed in seconds, but become unacceptably poor when the results are converted into INR (CV = 18.8%) because of the high ISI value of the thromboplastin used. We think that the Monitor might be suitable for monitoring oral anticoagulant therapy if the manufacturer would provide a more sensitive thromboplastin in the cartridges.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8165612

Source DB:  PubMed          Journal:  Thromb Haemost        ISSN: 0340-6245            Impact factor:   5.249


  12 in total

Review 1.  Out-of-hospital coagulation monitoring and management.

Authors:  J E Ansell
Journal:  J Thromb Thrombolysis       Date:  1999-04       Impact factor: 2.300

Review 2.  The role of point-of-care anticoagulation monitoring in arterial and venous thromboembolic disorders.

Authors:  C R Zimmerman
Journal:  J Thromb Thrombolysis       Date:  2000-04       Impact factor: 2.300

3.  European Concerted Action on Anticoagulation (ECAA). An assessment of lyophilised plasmas for ISI calibration of CoaguChek and TAS whole blood prothrombin time monitors.

Authors:  L Poller; M Keown; N Chauhan; A M H P van den Besselaar; A Tripodi; C Shiach; J Jespersen
Journal:  J Clin Pathol       Date:  2003-02       Impact factor: 3.411

4.  Accuracy and clinical utility of the CoaguChek XS portable international normalised ratio monitor in a pilot study of warfarin home-monitoring.

Authors:  Luke R Bereznicki; Shane L Jackson; Gregory M Peterson; Ella C Jeffrey; Katherine A Marsden; David M Jupe
Journal:  J Clin Pathol       Date:  2006-06-02       Impact factor: 3.411

Review 5.  Oral anticoagulant therapy: Antithrombotic Therapy and Prevention of Thrombosis, 9th ed: American College of Chest Physicians Evidence-Based Clinical Practice Guidelines.

Authors:  Walter Ageno; Alexander S Gallus; Ann Wittkowsky; Mark Crowther; Elaine M Hylek; Gualtiero Palareti
Journal:  Chest       Date:  2012-02       Impact factor: 9.410

6.  Monitoring oral anticoagulant treatment with the TAS near-patient test system: comparison with conventional thromboplastins.

Authors:  S Kitchen; F E Preston
Journal:  J Clin Pathol       Date:  1997-11       Impact factor: 3.411

Review 7.  Accuracy, precision, and quality control for point-of-care testing of oral anticoagulation.

Authors:  A M van den Besselaar
Journal:  J Thromb Thrombolysis       Date:  2001-09       Impact factor: 2.300

8.  Reliability of international normalised ratios from two point of care test systems: comparison with conventional methods.

Authors:  Leon Poller; Michelle Keown; Nikhil Chauhan; Anton M H P van den Besselaar; Armando Tripodi; Caroline Shiach; Jorgen Jespersen
Journal:  BMJ       Date:  2003-07-05

Review 9.  Home monitoring of anticoagulation.

Authors:  Julie Hambleton
Journal:  J Thromb Thrombolysis       Date:  2003 Aug-Oct       Impact factor: 2.300

Review 10.  The future of anticoagulation clinics.

Authors:  B Gail Macik
Journal:  J Thromb Thrombolysis       Date:  2003 Aug-Oct       Impact factor: 2.300

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.