Literature DB >> 8123404

A new method of measuring cardiac output in man using lithium dilution.

R A Linton1, D M Band, K M Haire.   

Abstract

We describe a new indicator dilution method of measuring cardiac output in man. A bolus injection of lithium chloride 0.6 mmol was given via a central venous catheter and arterial plasma [Li+] recorded using a specially developed sensor incorporating an Li(+)-selective electrode. Cardiac output was derived from the lithium dilution curve, with a correction for packed cell volume. Lithium dilution cardiac output (LiDCO) was compared with thermodilution cardiac output (TD) using 22 lithium sensors in nine patients. For each sensor, one LiDCO was measured immediately before and one immediately after three TD estimations and mean values of LiDCO and TD derived. The correlation coefficient, r, was 0.89; slope of the regression 0.84; y intercept 0.72; bias 0.3 (0.5) litre min-1 (mean (TD-LiDCO) (1 SD). LiDCO appeared to be a safe, simple and accurate technique which does not require insertion of a pulmonary artery catheter.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8123404     DOI: 10.1093/bja/71.2.262

Source DB:  PubMed          Journal:  Br J Anaesth        ISSN: 0007-0912            Impact factor:   9.166


  30 in total

Review 1.  Cardiac output monitoring devices: an analytic review.

Authors:  Jahan Porhomayon; Ali El-Solh; Peter Papadakos; Nader Djalal Nader
Journal:  Intern Emerg Med       Date:  2011-12-07       Impact factor: 3.397

Review 2.  [Measurement of cardiac output].

Authors:  D A Reuter; A E Goetz
Journal:  Anaesthesist       Date:  2005-11       Impact factor: 1.041

Review 3.  [Pulmonary artery catheter in anaesthesiology and intensive care medicine].

Authors:  E E C de Waal; L de Rossi; W Buhre
Journal:  Anaesthesist       Date:  2006-06       Impact factor: 1.041

4.  Applications of minimally invasive cardiac output monitors.

Authors:  Jahan Porhomayon; Gino Zadeii; Samuel Congello; Nader D Nader
Journal:  Int J Emerg Med       Date:  2012-04-24

5.  Organ dysfunction during sepsis.

Authors:  Suveer Singh; Timothy W Evans
Journal:  Intensive Care Med       Date:  2006-02-11       Impact factor: 17.440

6.  Lithium dilution cardiac output measurement in the critically ill patient: determination of precision of the technique.

Authors:  M Cecconi; D Dawson; R M Grounds; A Rhodes
Journal:  Intensive Care Med       Date:  2008-09-18       Impact factor: 17.440

Review 7.  Cardiac output in 1998.

Authors:  M Singer
Journal:  Heart       Date:  1998-05       Impact factor: 5.994

Review 8.  Methods in pharmacology: measurement of cardiac output.

Authors:  Bart F Geerts; Leon P Aarts; Jos R Jansen
Journal:  Br J Clin Pharmacol       Date:  2011-03       Impact factor: 4.335

9.  Refractory caffeine and ergot-induced cervico-cerebral vasospasm and stroke treated with combined medical and endovascular approach.

Authors:  Megan Miller; Avinash B Kumar; Charles R Callison
Journal:  Neuroradiology       Date:  2011-04-06       Impact factor: 2.804

10.  A comparison of lithium dilution cardiac output measurements made using central and antecubital venous injection of lithium chloride.

Authors:  M M Jonas; F E Kelly; R A Linton; D M Band; T K O'Brien; N W Linton
Journal:  J Clin Monit Comput       Date:  1999-12       Impact factor: 2.502

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.