Literature DB >> 8119038

Progressive subluxation and polyethylene wear in total knee replacements with flat articular surfaces.

E L Feng1, S D Stulberg, R L Wixson.   

Abstract

One hundred eighty-six Microloc tricompartmental, cruciate-sparing, primary total knee replacements in 136 patients were performed between 1983 and 1987. Femoral components were made of cobalt-chrome-molybdenum alloy. The tibial component baseplates were made of titanium-aluminum-vanadium alloy. The baseplates were made with three small porous-coated pegs for fixation with or without cement, or with a central stem for fixation with cement. The polyethylene was affixed to the baseplate by a mechanical locking mechanism that was nonmodular. The articular surfaces of both components were flat mediolaterally and anteroposteriorly. The patellar components were dome shaped and metal backed with titanium-aluminum alloy. Seventy-three percent of the femoral components, 26% of the tibial components, and 48% of the patellar components were inserted without bone cement. The average time to maximum follow-up examination was 6.1 years (range, four to nine years). Of implants that had not been revised, 84.4% had good or excellent results (using the Hospital for Special Surgery scoring system) at final follow-up examination. The average range of motion of functioning implants at final follow-up examination was 108 degrees. Revisions for failure only of the metal-backed patellar component were performed in 22 knees (11.8%). Forty knees (21.5%) required revision for failure of the femoral-tibial articulation. Reasons for failure in this group included: polyethylene wear (57.5%); loosening (15.0%); tibial tray fracture (10.0%); sepsis (12.5%); and dislocation or ligament laxity (5.0%). An additional 15 functioning knees (8.1%) have radiographic evidence of progressive femoral-tibial subluxation. Future failure of these devices is considered likely. Polyethylene wear requiring revision was not statistically associated with patient age, gender, preoperative diagnosis, height, weight, or component size. Polyethylene failure leading to revision was related to the radiographic appearance of femoral-tibial component subluxation. This subluxation was most likely to occur after five years of component implantation. The development of progressive femoral-tibial subluxation was statistically associated with postoperative extremity malalignment, excessive varus positioning of the tibial component, bone grafting of the tibial plateau, the use of the small-pegged tibial component, and the use of this component without cement. Polyethylene wear associated with progressive femoral-tibial subluxation occurred at the periphery of the tibial plateau and along the raised portion of the tibial spine. The metal baseplate at the edge of the plateau was frequently exposed and worn. Bone lysis associated with the presence of polyethylene, metal, and cement debris was frequently observed.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 8119038

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  16 in total

1.  Posterior cruciate ligament function following total knee arthroplasty: the effect of joint line elevation.

Authors:  G J Emodi; J J Callaghan; D R Pedersen; T D Brown
Journal:  Iowa Orthop J       Date:  1999

2.  Durability of a cruciate-retaining TKA with modular tibial trays at 20 years.

Authors:  John J Callaghan; Mitchell W Beckert; David W Hennessy; Devon D Goetz; Scott S Kelley
Journal:  Clin Orthop Relat Res       Date:  2013-01       Impact factor: 4.176

3.  The Influence of Component Alignment and Ligament Properties on Tibiofemoral Contact Forces in Total Knee Replacement.

Authors:  Colin R Smith; Michael F Vignos; Rachel L Lenhart; Jarred Kaiser; Darryl G Thelen
Journal:  J Biomech Eng       Date:  2016-02       Impact factor: 2.097

4.  Revision total knee arthroplasty for major osteolysis.

Authors:  R Stephen J Burnett; James A Keeney; William J Maloney; John C Clohisy
Journal:  Iowa Orthop J       Date:  2009

5.  In vivo kinematics after a cruciate-substituting TKA.

Authors:  Jan Victor; John Kyle P Mueller; Richard D Komistek; Adrija Sharma; Matthew C Nadaud; Johan Bellemans
Journal:  Clin Orthop Relat Res       Date:  2009-09-04       Impact factor: 4.176

6.  No condylar lift-off occurs because of excessive lateral soft tissue laxity in neutrally aligned total knee arthroplasty: a computer simulation study.

Authors:  Shinichi Kuriyama; Masahiro Ishikawa; Shinichiro Nakamura; Moritoshi Furu; Hiromu Ito; Shuichi Matsuda
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-07-04       Impact factor: 4.342

7.  Assessment of the midflexion rotational laxity in posterior-stabilized total knee arthroplasty.

Authors:  Kazunori Hino; Tatsuhiko Kutsuna; Yoshio Oonishi; Kunihiko Watamori; Hiroshi Kiyomatsu; Yasutake Iseki; Seiji Watanabe; Yasumitsu Ishimaru; Hiromasa Miura
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-05-31       Impact factor: 4.342

8.  Routine surveillance of modular PFC TKA shows increasing failures after 10 years.

Authors:  Andrew S Malin; John J Callaghan; Kevin J Bozic; Steve S Liu; Devon D Goetz; Nicholas Sullivan; Scott S Kelley
Journal:  Clin Orthop Relat Res       Date:  2010-03-19       Impact factor: 4.176

9.  Retrieved Unicompartmental Implants with Full PE Tibial Components: The Effects of Knee Alignment and Polyethylene Thickness on Creep and Wear.

Authors:  Ph Hernigou; A Poignard; P Filippini; S Zilber
Journal:  Open Orthop J       Date:  2008-04-11

10.  Femoral Component Varus Malposition is Associated with Tibial Aseptic Loosening After TKA.

Authors:  Bum-Sik Lee; Hyun-Ik Cho; Seong-Il Bin; Jong-Min Kim; Byeong-Kyu Jo
Journal:  Clin Orthop Relat Res       Date:  2018-02       Impact factor: 4.176

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.