Literature DB >> 8116386

Stress shielding and bone resorption in THA: clinical versus computer-simulation studies.

R Huiskes1.   

Abstract

"Stress shielding" of bone around noncemented prosthetic hip stems causes long-term adaptive bone resorption which threatens the integrity of the fixation. Recently, computer-simulation models based on adaptive bone-remodeling theory in combination with finite-element methods have been developed. These models can be used to predict the extent of long-term resorption. In this paper a comparison is presented between the results of these predictions and those of precise measurements in retrieval hip-replacement specimens reported by Engh and associates (1992). It is shown that certainly the predictions and the actual clinical findings are subject to the same trends. Under certain assumptions, these results even match precisely. It is also shown that both clinical results and simulation predictions can be approximated by a simple formula, in which the amount of bone loss is related to the ratio between stem stiffness and preoperative bone density.

Entities:  

Mesh:

Year:  1993        PMID: 8116386

Source DB:  PubMed          Journal:  Acta Orthop Belg        ISSN: 0001-6462            Impact factor:   0.500


  9 in total

1.  A cementless hip system with a new surface for osseous integration.

Authors:  Richard Lass; Alexander Kolb; Gobert Skrbensky; Georg Reinisch; Bernd Kubista; Alexander Giurea; Reinhard Windhager; Rainer Kotz
Journal:  Int Orthop       Date:  2013-10-11       Impact factor: 3.075

2.  Three-dimensional nano-architected scaffolds with tunable stiffness for efficient bone tissue growth.

Authors:  Alessandro Maggi; Hanqing Li; Julia R Greer
Journal:  Acta Biomater       Date:  2017-09-18       Impact factor: 8.947

3.  A paradigm for the development and evaluation of novel implant topologies for bone fixation: in vivo evaluation.

Authors:  Jason P Long; Scott J Hollister; Steven A Goldstein
Journal:  J Biomech       Date:  2012-09-02       Impact factor: 2.712

4.  Congenital hip dysplasia treated by total hip arthroplasty using cementless tapered stem in patients younger than 50 years old: results after 12-years follow-up.

Authors:  Cesare Faldini; Maria Teresa Miscione; Mohammadreza Chehrassan; Francesco Acri; Camilla Pungetti; Michele d'Amato; Deianira Luciani; Sandro Giannini
Journal:  J Orthop Traumatol       Date:  2011-11-24

Review 5.  Current strategies to improve the bioactivity of PEEK.

Authors:  Rui Ma; Tingting Tang
Journal:  Int J Mol Sci       Date:  2014-03-28       Impact factor: 5.923

6.  Comparison of periprosthetic bone remodeling after implantation of anatomic and tapered cementless femoral stems in total hip arthroplasty: A prospective cohort study protocol.

Authors:  Xiang-Dong Wu; Yu Chen; Zhang-Yu Wang; Yu-Jian Li; Zheng-Lin Zhu; Yu-Zhang Tao; Hong Chen; Qiang Cheng; Wei Huang
Journal:  Medicine (Baltimore)       Date:  2018-09       Impact factor: 1.889

7.  The effect of humeral implant thickness and canal fill on interface contact and bone stresses in the proximal humerus.

Authors:  Stephanie Synnott; G Daniel G Langohr; Jacob M Reeves; James A Johnson; George S Athwal
Journal:  JSES Int       Date:  2021-07-08

8.  Generic rules of mechano-regulation combined with subject specific loading conditions can explain bone adaptation after THA.

Authors:  Tomasz D Szwedowski; William R Taylor; Markus O Heller; Carsten Perka; Michael Müller; Georg N Duda
Journal:  PLoS One       Date:  2012-05-02       Impact factor: 3.240

9.  Design of Customize Interbody Fusion Cages of Ti64ELI with Gradient Porosity by Selective Laser Melting Process.

Authors:  Cheng-Tang Pan; Che-Hsin Lin; Ya-Kang Huang; Jason S C Jang; Hsuan-Kai Lin; Che-Nan Kuo; De-Yao Lin; Jacob C Huang
Journal:  Micromachines (Basel)       Date:  2021-03-15       Impact factor: 2.891

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.