Frequency response of PVDF needle-type hydrophones.

B Fay1, G Ludwig, C Lankjaer, P A Lewin.   

Abstract

This paper examines the factors governing the frequency response of ultrasonic polyvinylidene fluoride (PVDF) polymer needle-type hydrophones, in particular the sensitivity variations in the lower frequency range of 1-6 MHz. A theoretical model was used to analyze the influence of the hydrophone's diameter, the metal electrodes, thickness, PVDF material properties, the adhesive layer acoustical characteristics and the backing material, on the frequency response of the hydrophone. The results of the theoretical modelling differ by less than +/- 0.5 dB from those obtained experimentally from the reciprocity calibration in the frequency range 1-20 MHz. It is shown that the needle hydrophone's diameter and backing material are the main reasons for the sensitivity variations observed in the frequency range below 6 MHz.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 8085292     DOI: 10.1016/0301-5629(94)90004-3

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  7 in total

1.  Considerations for Choosing Sensitive Element Size for Needle and Fiber-Optic Hydrophones-Part I: Spatiotemporal Transfer Function and Graphical Guide.

Authors:  Keith A Wear
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-12-10       Impact factor: 2.725

2.  Directivity and Frequency-Dependent Effective Sensitive Element Size of Membrane Hydrophones: Theory Versus Experiment.

Authors:  Keith A Wear; Christian Baker; Piero Miloro
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2019-07-24       Impact factor: 2.725

3.  Hydrophone Spatial Averaging Correction for Acoustic Exposure Measurements From Arrays-Part I: Theory and Impact on Diagnostic Safety Indexes.

Authors:  Keith A Wear
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2021-02-25       Impact factor: 2.725

4.  A PVDF receiver for ultrasound monitoring of transcranial focused ultrasound therapy.

Authors:  Meaghan A O'Reilly; Kullervo Hynynen
Journal:  IEEE Trans Biomed Eng       Date:  2010-05-27       Impact factor: 4.538

5.  Directivity and Frequency-Dependent Effective Sensitive Element Size of a Reflectance-Based Fiber-Optic Hydrophone: Predictions From Theoretical Models Compared With Measurements.

Authors:  Keith A Wear; Samuel M Howard
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-10-01       Impact factor: 2.725

6.  Pressure Pulse Distortion by Needle and Fiber-Optic Hydrophones due to Nonuniform Sensitivity.

Authors:  Keith A Wear; Yunbo Liu; Gerald R Harris
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-02       Impact factor: 2.725

7.  Directivity and Frequency-Dependent Effective Sensitive Element Size of Needle Hydrophones: Predictions From Four Theoretical Forms Compared With Measurements.

Authors:  Keith A Wear; Christian Baker; Piero Miloro
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-07-13       Impact factor: 2.725

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.