The Harris-Galante porous acetabular component press-fit without screw fixation. Five-year radiographic analysis of primary cases.

T P Schmalzried1, S J Wessinger, G E Hill, W H Harris.   

Abstract

One hundred twenty-two primary total hip arthroplasties were followed for an average of 56 months (range, 48-66 months) in which the Harris-Galante (Zimmer, Warsaw, IN) porous ingrowth acetabular component had been press-fit into the innominate bone without screw fixation. There were no acetabular fractures. No socket was revised for loosening and none were radiographically loose. There was no evidence of disruption of the titanium porous mesh. There was no acetabular osteolysis. Compared to the authors' series of primary hip reconstructions using this same prosthesis inserted with line-to-line reaming and screw fixation, the data indicate that the tight peripheral fit associated with the press-fit technique is effective in reducing both the incidence and extent of bone-implant radiolucencies. However, the increased incidence of radiolucencies near the apex of the acetabulum also suggest that initial contact of the porous surface with live acetabular bone at this location is desirable in order to obtain and maintain an optimal bone-implant interface. Additional studies are necessary to further establish the relationship between the initial fit and long-term fixation of cementless acetabular components. Based on the data and other considerations for eliminating both vascular risk and the potential for fretting wear between the screws and shell, the authors recommend press-fitting without screw fixation for this acetabular component in primary cases when anatomy and bone stock permit. Full seating of the component is recommended in order to obtain dome contact.

Entities:  

Mesh:

Year:  1994        PMID: 8077971     DOI: 10.1016/0883-5403(94)90077-9

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  15 in total

1.  Radiographic evaluation of the Duraloc cup after 4 years.

Authors:  B Stoeckl; E Brabec; S Wanner; M Krismer; R Biedermann
Journal:  Int Orthop       Date:  2004-10-14       Impact factor: 3.075

2.  Effect of design on the initial stability of press-fit cups in the presence of acetabular rim defects: experimental evaluation of the effect of adding circumferential fins.

Authors:  Wolfgang O Huber; Philip C Noble
Journal:  Int Orthop       Date:  2013-11-22       Impact factor: 3.075

3.  Limitation of total hip arthroplasty of the acetabular roof by press-fit without screw fixation: discussion of a biomechanical study.

Authors:  Akio Kanda; Kazuo Kaneko; Osamu Obayashi; Atsuhiko Mogami; Hideaki Iwase
Journal:  Eur J Orthop Surg Traumatol       Date:  2012-04-07

4.  Bone remodelling around HA-coated acetabular cups : a DEXA study with a 3-year follow-up in a randomised trial.

Authors:  M B Laursen; P T Nielsen; K Søballe
Journal:  Int Orthop       Date:  2006-06-08       Impact factor: 3.075

5.  A hierarchy of computationally derived surgical and patient influences on metal on metal press-fit acetabular cup failure.

Authors:  S G Clarke; A T M Phillips; A M J Bull; J P Cobb
Journal:  J Biomech       Date:  2012-04-16       Impact factor: 2.712

6.  A stature-specific concept for uncemented, primary total hip arthroplasty.

Authors:  Georg W Omlor; Hannah Ullrich; Knut Krahmer; Alexander Jung; Günther Aldinger; Peter Aldinger
Journal:  Acta Orthop       Date:  2010-02       Impact factor: 3.717

7.  Survivorship of monoblock trabecular metal cups in primary THA : midterm results.

Authors:  Konstantinos N Malizos; Konstantinos Bargiotas; Loukia Papatheodorou; Michael Hantes; Theofilos Karachalios
Journal:  Clin Orthop Relat Res       Date:  2008-01-03       Impact factor: 4.176

8.  Cup press fit in uncemented THA depends on sex, acetabular shape, and surgical technique.

Authors:  Eduardo García-Rey; Eduardo García-Cimbrelo; Ana Cruz-Pardos
Journal:  Clin Orthop Relat Res       Date:  2012-11       Impact factor: 4.176

9.  Objective evaluation for initial stability of highly porous cup without screws in total hip arthroplasty for femoral neck fracture.

Authors:  Hideo Kobayashi; Yasuhiro Homma; Hiroki Tanabe; Taiji Watari; Hironori Ochi; Sammy Banno; Tomonori Baba; Kazuo Kaneko
Journal:  J Orthop       Date:  2019-08-10

10.  Incorporation of screwless press-fit acetabular cups and disappearance of polar gaps.

Authors:  Sanjay Agarwala; Chintan Jadia; Mayank Vijayvargiya
Journal:  J Clin Orthop Trauma       Date:  2018-11-30
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.