Limitation of total hip arthroplasty of the acetabular roof by press-fit without screw fixation: discussion of a biomechanical study.

Akio Kanda1, Kazuo Kaneko, Osamu Obayashi, Atsuhiko Mogami, Hideaki Iwase.   

Abstract

In total hip arthroplasty of the acetabular roof fixed by press-fit without screw fixation, there is little possibility for loosening to occur, because it is difficult for wear debris to enter between the cup and the acetabular roof, as screw holes are not present. However, stability is provided only by contact. In the case of acetabular dysplasia, it is not well understood whether sufficient initial fixation power is provided. We performed a torsion test and a lever-out test. In the torsion test, in the case of a normal hip joint, as the cup grew bigger, the fixation power tended to increase in strength. In the acetabular dysplasia model, with cups of each size, as the protrusion angle increased, the fixation power of the cup tended to become weak. When the protrusion angle approaches 15 degrees, we must use a cup that is 4 mm larger than the original cup to achieve the same initial fixation power. Furthermore, when the protrusion angle is 15 degrees in cups that are over 48 mm in size, we obtain fixation power that is theoretically adequate, but when small cups, for example, 46 mm in size are set with protrusion, the initial fixation power decreases significantly, and we cannot obtain a fixation power that is theoretically adequate.

Entities:  

Mesh:

Year:  2012        PMID: 23412291     DOI: 10.1007/s00590-012-0985-0

Source DB:  PubMed          Journal:  Eur J Orthop Surg Traumatol        ISSN: 1633-8065


  8 in total

1.  The effect of superior placement of the acetabular component on the rate of loosening after total hip arthroplasty.

Authors:  W Pagnano; A D Hanssen; D G Lewallen; W J Shaughnessy
Journal:  J Bone Joint Surg Am       Date:  1996-07       Impact factor: 5.284

2.  A comparison of three varieties of noncemented porous-coated hip replacement.

Authors:  R J Haddad; S D Cook; M R Brinker
Journal:  J Bone Joint Surg Br       Date:  1990-01

Review 3.  Wear in total hip and knee replacements.

Authors:  T P Schmalzried; J J Callaghan
Journal:  J Bone Joint Surg Am       Date:  1999-01       Impact factor: 5.284

4.  The Harris-Galante porous acetabular component press-fit without screw fixation. Five-year radiographic analysis of primary cases.

Authors:  T P Schmalzried; S J Wessinger; G E Hill; W H Harris
Journal:  J Arthroplasty       Date:  1994-06       Impact factor: 4.757

5.  Periprosthetic bone loss in total hip arthroplasty. Polyethylene wear debris and the concept of the effective joint space.

Authors:  T P Schmalzried; M Jasty; W H Harris
Journal:  J Bone Joint Surg Am       Date:  1992-07       Impact factor: 5.284

6.  Case report: femoral neuropathy secondary to total hip arthroplasty wear debris.

Authors:  Samo K Fokter; Alenka Repse-Fokter; Iztok Takac
Journal:  Clin Orthop Relat Res       Date:  2009-05-19       Impact factor: 4.176

Review 7.  Hip joint loading during walking and running, measured in two patients.

Authors:  G Bergmann; F Graichen; A Rohlmann
Journal:  J Biomech       Date:  1993-08       Impact factor: 2.712

8.  Polyethylene sockets and alumina ceramic heads in cemented total hip arthroplasty. A ten-year study.

Authors:  N Sugano; T Nishii; K Nakata; K Masuhara; K Takaoka
Journal:  J Bone Joint Surg Br       Date:  1995-07
  8 in total
  5 in total

1.  Influence of cup-center-edge angle on micro-motion at the interface between the cup and host bone in cementless total hip arthroplasty: three-dimensional finite element analysis.

Authors:  Nobuhiro Kaku; Tomonori Tabata; Hiroshi Tsumura
Journal:  Eur J Orthop Surg Traumatol       Date:  2015-08-29

2.  The biological and biomechanical comparison of two bulk bone graft techniques used in case of dysplastic acetabulum.

Authors:  János Szabó; Sándor Manó; Ádám Lőrinc; Gyula Győrfi; László Kiss; Zoltán Csernátony
Journal:  Eur J Orthop Surg Traumatol       Date:  2013-06-01

3.  Objective evaluation for initial stability of highly porous cup without screws in total hip arthroplasty for femoral neck fracture.

Authors:  Hideo Kobayashi; Yasuhiro Homma; Hiroki Tanabe; Taiji Watari; Hironori Ochi; Sammy Banno; Tomonori Baba; Kazuo Kaneko
Journal:  J Orthop       Date:  2019-08-10

4.  Initial stability of cementless acetabular cups: press-fit and screw fixation interaction--an in vitro biomechanical study.

Authors:  Tomonori Tabata; Nobuhiro Kaku; Katsutoshi Hara; Hiroshi Tsumura
Journal:  Eur J Orthop Surg Traumatol       Date:  2014-11-25

5.  Laser Resonance Frequency Analysis: A Novel Measurement Approach to Evaluate Acetabular Cup Stability During Surgery.

Authors:  Shunsuke Kikuchi; Katsuhiro Mikami; Daisuke Nakashima; Toshiyuki Kitamura; Noboru Hasegawa; Masaharu Nishikino; Arihiko Kanaji; Masaya Nakamura; Takeo Nagura
Journal:  Sensors (Basel)       Date:  2019-11-08       Impact factor: 3.576

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.