Literature DB >> 8077393

Comparison of BACTEC Plus 26 and 27 media with and without fastidious organism supplement with conventional methods for culture of sterile body fluids.

D D Fuller1, T E Davis, P C Kibsey, L Rosmus, L W Ayers, M Ott, M A Saubolle, D L Sewell.   

Abstract

We compared the BACTEC Plus 26/27 culture system (Becton Dickinson Diagnostic Instrument Systems, Sparks, Md.) with and without fastidious organism supplement with conventional centrifugation preparation and plating for the recovery and speed of detection of microorganisms. A total of 1,101 sterile body fluid specimens were collected and processed at five hospital laboratories, yielding 234 (21%) positive cultures. Of the 176 isolates considered clinically significant, 133 (76%) were recovered by both the BACTEC system and conventional culture, while 28 (16% [P < 0.005]) were recovered by BACTEC only and 11 (6%) were recovered by conventional culture alone. There were no statistically significant differences in the speed of detection of microbial growth. It was found that BACTEC, with or without the addition of fastidious organism supplement, exhibited improved sensitivity for the recovery of microorganisms, including fastidious bacteria.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 8077393      PMCID: PMC264024          DOI: 10.1128/jcm.32.6.1488-1491.1994

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  11 in total

1.  Comparison of two commercial broth-culture systems for microbial detection in dialysates of patients on continuous ambulatory peritoneal dialysis.

Authors:  M A Saubolle; D L Sewell; M D Holland; T A Golper
Journal:  Diagn Microbiol Infect Dis       Date:  1989 Nov-Dec       Impact factor: 2.803

2.  High prevalence of Kingella kingae in joint fluid from children with septic arthritis revealed by the BACTEC blood culture system.

Authors:  P Yagupsky; R Dagan; C W Howard; M Einhorn; I Kassis; A Simu
Journal:  J Clin Microbiol       Date:  1992-05       Impact factor: 5.948

3.  Addi-Chek filtration, BACTEC, and 10-ml culture methods for recovery of microorganisms from dialysis effluent during episodes of peritonitis.

Authors:  B M Males; J J Walshe; L Garringer; D Koscinski; D Amsterdam
Journal:  J Clin Microbiol       Date:  1986-02       Impact factor: 5.948

4.  Improved method of isolating bacteria from joint fluids by the use of blood culture bottles.

Authors:  R von Essen; A Hölttä
Journal:  Ann Rheum Dis       Date:  1986-06       Impact factor: 19.103

5.  Microbiological diagnosis of peritonitis in patients on continuous ambulatory peritoneal dialysis.

Authors:  S I Vas; L Law
Journal:  J Clin Microbiol       Date:  1985-04       Impact factor: 5.948

6.  Evaluation of broth media for routine culture of cerebrospinal and joint fluid specimens.

Authors:  C E Reinhold; D J Nickolai; T E Piccinini; B A Byford; M K York; G F Brooks
Journal:  Am J Clin Pathol       Date:  1988-05       Impact factor: 2.493

7.  Inoculation of blood culture bottles with ascitic fluid. Improved detection of spontaneous bacterial peritonitis.

Authors:  B A Runyon; E T Umland; T Merlin
Journal:  Arch Intern Med       Date:  1987-01

8.  Bedside inoculation of blood culture bottles with ascitic fluid is superior to delayed inoculation in the detection of spontaneous bacterial peritonitis.

Authors:  B A Runyon; M R Antillon; E A Akriviadis; J G McHutchison
Journal:  J Clin Microbiol       Date:  1990-12       Impact factor: 5.948

Review 9.  Microbiological aspects of peritonitis associated with continuous ambulatory peritoneal dialysis.

Authors:  A von Graevenitz; D Amsterdam
Journal:  Clin Microbiol Rev       Date:  1992-01       Impact factor: 26.132

10.  Tuberculous pleural effusions: increased culture yield with bedside inoculation of pleural fluid and poor diagnostic value of adenosine deaminase.

Authors:  G Maartens; E D Bateman
Journal:  Thorax       Date:  1991-02       Impact factor: 9.139

View more
  9 in total

1.  Culture with BACTEC Peds Plus/F bottle compared with conventional methods for detection of bacteria in synovial fluid.

Authors:  J G Hughes; E A Vetter; R Patel; C D Schleck; S Harmsen; L T Turgeant; F R Cockerill
Journal:  J Clin Microbiol       Date:  2001-12       Impact factor: 5.948

2.  [Improving the diagnosis of septic arthritis by use of a pediatric blood culture system].

Authors:  S Weiss; H Geiss; M Kommerell; H-G Simank; L Bernd; P Henle
Journal:  Orthopade       Date:  2006-04       Impact factor: 1.087

3.  The additional value of blood culture bottles in the diagnosis of endophthalmitis.

Authors:  H S Tan; E A E Ghyczy-Carlborg; L Spanjaard; M D de Smet
Journal:  Eye (Lond)       Date:  2011-06-17       Impact factor: 3.775

4.  Sample taking during orthopedic surgery: sensitivity and specificity using the BACTEC blood culture system.

Authors:  L E Podleska; S Lendemans; E Schmid; B Hussmann; D Nast-Kolb; G Taeger
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2011-05-22       Impact factor: 3.267

5.  Rapid identification of microorganisms from sterile body fluids by use of FilmArray.

Authors:  Osman Altun; Mohammed Almuhayawi; Måns Ullberg; Volkan Özenci
Journal:  J Clin Microbiol       Date:  2014-12-17       Impact factor: 5.948

6.  Synovial fluid culture: agar plates vs. blood culture bottles for microbiological identification.

Authors:  Daniel Cohen; Ayman Natshe; Eli Ben Chetrit; Ehud Lebel; Gabriel S Breuer
Journal:  Clin Rheumatol       Date:  2019-09-06       Impact factor: 2.980

7.  Pseudo-outbreak of Klebsiella oxytoca spontaneous bacterial peritonitis attributed to contamination of multidose vials of culture medium supplement.

Authors:  Federico Perez; Abhishek Deshpande; Sirisha Kundrapu; Andrea M Hujer; Robert A Bonomo; Curtis J Donskey
Journal:  Infect Control Hosp Epidemiol       Date:  2013-12-23       Impact factor: 3.254

8.  Sensitivity and rapidity of blood culture bottles in the detection of cornea organ culture media contamination by bacteria and fungi.

Authors:  G Thuret; A Carricajo; C Chiquet; A C Vautrin; N Celle; M Boureille; S Acquart; G Aubert; J Maugery; P Gain
Journal:  Br J Ophthalmol       Date:  2002-12       Impact factor: 4.638

9.  Use of the BacT/Alert blood culture system for culture of sterile body fluids other than blood.

Authors:  P Bourbeau; J Riley; B J Heiter; R Master; C Young; C Pierson
Journal:  J Clin Microbiol       Date:  1998-11       Impact factor: 5.948

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.