Literature DB >> 2625034

Comparison of two commercial broth-culture systems for microbial detection in dialysates of patients on continuous ambulatory peritoneal dialysis.

M A Saubolle1, D L Sewell, M D Holland, T A Golper.   

Abstract

The capability of two commercial systems was studied for microbial detection in dialysis effluents from patients on continuous ambulatory peritoneal dialysis (CAPD). Two methods of processing dialysate from patients on CAPD were compared: (a) direct inoculation of 10 ml of dialysate into a single bottle broth culture system (Signal; Oxoid, U.S.A., Columbia, Maryland) and 5 ml into each of two BACTEC blood culture bottles (Johnston Laboratories, Towson, Maryland); and (b) centrifugation of 50 ml of dialysate and culture of the sediment in an Oxoid bottle. Of the 196 specimens cultured, 99 (51%) yielded growth. Recovery rates of significant isolates were 95% for the BACTEC system, 89% for the Oxoid system, and 88% for the centrifugation-Oxoid system. Recovery of eight isolates from the Oxoid system was by subculture rather than a visual "signal." The Oxoid system is a practical, cost-effective, alternative culture method for effluents from CAPD patients in laboratories not having access to the BACTEC system.

Entities:  

Mesh:

Year:  1989        PMID: 2625034     DOI: 10.1016/0732-8893(89)90077-1

Source DB:  PubMed          Journal:  Diagn Microbiol Infect Dis        ISSN: 0732-8893            Impact factor:   2.803


  5 in total

1.  Comparison of BACTEC Plus 26 and 27 media with and without fastidious organism supplement with conventional methods for culture of sterile body fluids.

Authors:  D D Fuller; T E Davis; P C Kibsey; L Rosmus; L W Ayers; M Ott; M A Saubolle; D L Sewell
Journal:  J Clin Microbiol       Date:  1994-06       Impact factor: 5.948

2.  Clinical comparison of isolator, Septi-Chek, nonvented tryptic soy broth, and direct agar plating combined with thioglycolate broth for diagnosing spontaneous bacterial peritonitis.

Authors:  J E Hay; F R Cockerill; D Kaese; E A Vetter; P C Wollan; J Rakela; M P Wilhelm
Journal:  J Clin Microbiol       Date:  1996-01       Impact factor: 5.948

3.  Use of a pair of blood culture bottles for sterility testing of corneal organ culture media.

Authors:  P Gain; G Thuret; C Chiquet; A C Vautrin; A Carricajo; S Acquart; J Maugery; G Aubert
Journal:  Br J Ophthalmol       Date:  2001-10       Impact factor: 4.638

4.  Sensitivity and rapidity of blood culture bottles in the detection of cornea organ culture media contamination by bacteria and fungi.

Authors:  G Thuret; A Carricajo; C Chiquet; A C Vautrin; N Celle; M Boureille; S Acquart; G Aubert; J Maugery; P Gain
Journal:  Br J Ophthalmol       Date:  2002-12       Impact factor: 4.638

Review 5.  Microbiological aspects of peritonitis associated with continuous ambulatory peritoneal dialysis.

Authors:  A von Graevenitz; D Amsterdam
Journal:  Clin Microbiol Rev       Date:  1992-01       Impact factor: 26.132

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.