Literature DB >> 11724863

Culture with BACTEC Peds Plus/F bottle compared with conventional methods for detection of bacteria in synovial fluid.

J G Hughes1, E A Vetter, R Patel, C D Schleck, S Harmsen, L T Turgeant, F R Cockerill.   

Abstract

An evaluation was undertaken to determine the utility of the BACTEC Peds Plus/F bottle and the BACTEC 9240 instrument (Becton Dickinson Diagnostic Instrument Systems, Sparks, Md.) for the detection of clinically significant microorganisms in synovial fluid specimens. The Peds Plus/F bottle was used because in our laboratory the quantity of synovial fluid available for culture is frequently in the range of 0.5 to 3.0 ml. The culture results obtained with the Peds Plus/F bottle were compared to those obtained by a conventional agar plate method for a total of 805 synovial fluid specimens. Microbial growth was produced by 74 cultures (9.2%) from 60 patients, yielding a total of 77 microorganisms. Organisms were classified as pathogens (n = 62), contaminants (n = 12), or indeterminate (n = 3) on the basis of a review of the patients' medical histories. Culture using BACTEC Peds Plus/F bottle detected statistically significantly more pathogens overall (62 versus 51 pathogens [P = 0.001]) and statistically fewer contaminants overall (1 versus 11 contaminants [P = 0.006]) than culture by the agar plate method. These results indicate the superior performance of the BACTEC Peds Plus/F bottle over the conventional agar plate method for the detection of clinically significant microorganisms from synovial fluid specimens.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11724863      PMCID: PMC88567          DOI: 10.1128/JCM.39.12.4468-4471.2001

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  6 in total

1.  Use of the isolator 1.5 microbial tube for culture of synovial fluid from patients with septic arthritis.

Authors:  P Yagupsky; J Press
Journal:  J Clin Microbiol       Date:  1997-09       Impact factor: 5.948

2.  Culture of joint specimens in bacterial arthritis. Impact of blood culture bottle utilization.

Authors:  R von Essen
Journal:  Scand J Rheumatol       Date:  1997       Impact factor: 3.641

3.  High prevalence of Kingella kingae in joint fluid from children with septic arthritis revealed by the BACTEC blood culture system.

Authors:  P Yagupsky; R Dagan; C W Howard; M Einhorn; I Kassis; A Simu
Journal:  J Clin Microbiol       Date:  1992-05       Impact factor: 5.948

4.  Improved method of isolating bacteria from joint fluids by the use of blood culture bottles.

Authors:  R von Essen; A Hölttä
Journal:  Ann Rheum Dis       Date:  1986-06       Impact factor: 19.103

5.  Comparison of BACTEC Plus 26 and 27 media with and without fastidious organism supplement with conventional methods for culture of sterile body fluids.

Authors:  D D Fuller; T E Davis; P C Kibsey; L Rosmus; L W Ayers; M Ott; M A Saubolle; D L Sewell
Journal:  J Clin Microbiol       Date:  1994-06       Impact factor: 5.948

6.  Use of the BacT/Alert blood culture system for culture of sterile body fluids other than blood.

Authors:  P Bourbeau; J Riley; B J Heiter; R Master; C Young; C Pierson
Journal:  J Clin Microbiol       Date:  1998-11       Impact factor: 5.948

  6 in total
  45 in total

1.  Bacterial Motility Reveals Unknown Molecular Organization.

Authors:  Ismaël Duchesne; Simon Rainville; Tigran Galstian
Journal:  Biophys J       Date:  2015-11-17       Impact factor: 4.033

2.  Sonication of explanted prosthetic components in bags for diagnosis of prosthetic joint infection is associated with risk of contamination.

Authors:  Andrej Trampuz; Kerryl E Piper; Arlen D Hanssen; Douglas R Osmon; Franklin R Cockerill; James M Steckelberg; Robin Patel
Journal:  J Clin Microbiol       Date:  2006-02       Impact factor: 5.948

3.  False-negative culture results with fungal isolates from peritoneal dialysis fluid.

Authors:  Jason D Pimentel; Gary D Lum
Journal:  J Clin Microbiol       Date:  2006-03       Impact factor: 5.948

Review 4.  A Real Pain: Diagnostic Quandaries and Septic Arthritis.

Authors:  Cristina Costales; Susan M Butler-Wu
Journal:  J Clin Microbiol       Date:  2018-01-24       Impact factor: 5.948

5.  [Improving the diagnosis of septic arthritis by use of a pediatric blood culture system].

Authors:  S Weiss; H Geiss; M Kommerell; H-G Simank; L Bernd; P Henle
Journal:  Orthopade       Date:  2006-04       Impact factor: 1.087

6.  Rapid identification of microorganisms from sterile body fluids by use of FilmArray.

Authors:  Osman Altun; Mohammed Almuhayawi; Måns Ullberg; Volkan Özenci
Journal:  J Clin Microbiol       Date:  2014-12-17       Impact factor: 5.948

7.  Improved diagnosis of orthopedic implant-associated infection by inoculation of sonication fluid into blood culture bottles.

Authors:  María Eugenia Portillo; Margarita Salvadó; Andrej Trampuz; Ana Siverio; Albert Alier; Lluisa Sorli; Santos Martínez; Daniel Pérez-Prieto; Juan P Horcajada; Lluis Puig-Verdie
Journal:  J Clin Microbiol       Date:  2015-03-04       Impact factor: 5.948

8.  Optimal Periprosthetic Tissue Specimen Number for Diagnosis of Prosthetic Joint Infection.

Authors:  Trisha N Peel; Tim Spelman; Brenda L Dylla; John G Hughes; Kerryl E Greenwood-Quaintance; Allen C Cheng; Jayawant N Mandrekar; Robin Patel
Journal:  J Clin Microbiol       Date:  2016-12-28       Impact factor: 5.948

9.  Prosthetic joint infections.

Authors:  Saima Aslam; Rabih O Darouiche
Journal:  Curr Infect Dis Rep       Date:  2012-10       Impact factor: 3.725

10.  Septic arthritis in the native joint.

Authors:  Meghan B Brennan; Jennifer L Hsu
Journal:  Curr Infect Dis Rep       Date:  2012-10       Impact factor: 3.725

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.