Literature DB >> 12446379

Sensitivity and rapidity of blood culture bottles in the detection of cornea organ culture media contamination by bacteria and fungi.

G Thuret1, A Carricajo, C Chiquet, A C Vautrin, N Celle, M Boureille, S Acquart, G Aubert, J Maugery, P Gain.   

Abstract

AIMS: To test the bactericidal activity of standard organ culture medium, and to compare the sensitivity and rapidity of blood culture bottles with conventional microbiological methods for detection of bacteria and fungi inoculated in a standard cornea organ culture medium.
METHODS: The bactericidal activity of contaminated standard organ culture medium containing 100 IU/ml penicillin, 0.1 mg/ml streptomycin, and 0.25 micro g/ml amphotericin B was evaluated after 48 hours of incubation at 31 degrees C with five inocula of 14 bacteria. Two yeasts (Candida spp) and one Aspergillus were also tested. Contaminated media were then inoculated in three blood bottles (aerobic, anaerobic, fungal) placed in a Bactec 9240 automat; three conventional microbiological broths were the control. Changes in colour of organ culture medium and growth on conventional broth were screened daily by visual inspection. The sensitivity and rapidity of detection of contamination were compared between the three methods: blood bottle, conventional, and visual.
RESULTS: Organ culture medium eradicated five bacteria irrespective of the starting inoculums: Streptococcus pneumoniae, Branhamella catarrhalis, Escherichia coli, Propionibacterium acnes, and Haemophilus influenzae. For micro-organisms where the medium was ineffective or bactericidal only (methicillin resistant Staphylococcus aureus, methicillin sensitive Staphylococcus aureus, Staphylococcus epidermidis, Staphylococcus haemolyticus, Pseudomonas aeruginosa, Acinetobacter baumannii, Bacillus subtilis, Klebsiella pneumoniae, Enterococcus faecalis, Candida albicans, Candida kruzei, Aspergillus fumigatus), the blood bottle, conventional, and visual methods detected microbial growth in 100%, 76.5%, and 70% of cases respectively. Mean detection time using blood bottles was 15.1 hours (SD 13.8, range 2-52). In cases of detection by the blood bottle method and the conventional method, the former was always faster: 95.5% against 65.2% detection within 24 hours (p=0.022) respectively.
CONCLUSIONS: Blood bottles detect more efficiently and more rapidly a wider range of bacteria and fungi than the conventional microbiological method and the visual inspection of organ culture media.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12446379      PMCID: PMC1771388          DOI: 10.1136/bjo.86.12.1422

Source DB:  PubMed          Journal:  Br J Ophthalmol        ISSN: 0007-1161            Impact factor:   4.638


  28 in total

1.  Culture with BACTEC Peds Plus/F bottle compared with conventional methods for detection of bacteria in synovial fluid.

Authors:  J G Hughes; E A Vetter; R Patel; C D Schleck; S Harmsen; L T Turgeant; F R Cockerill
Journal:  J Clin Microbiol       Date:  2001-12       Impact factor: 5.948

2.  Enterococcus spp. produces slime and survives in rat peritoneal macrophages.

Authors:  L Baldassarri; R Cecchini; L Bertuccini; M G Ammendolia; F Iosi; C R Arciola; L Montanaro; R Di Rosa; G Gherardi; G Dicuonzo; G Orefici; R Creti
Journal:  Med Microbiol Immunol       Date:  2001-12       Impact factor: 3.402

3.  Corneoscleral rim cultures: lack of utility and implications for clinical decision-making and infection prevention in the care of patients undergoing corneal transplantation.

Authors:  R J Everts; W C Fowler; D H Chang; L B Reller
Journal:  Cornea       Date:  2001-08       Impact factor: 2.651

4.  Bacteriologic study of "donor" eyes. Evaluation of antibacterial treatments prior to corneal grafting.

Authors:  F M Polack; D Locatcher-Khorazo; E Gutierrez
Journal:  Arch Ophthalmol       Date:  1967-08

5.  Microbial contamination of donor eyes. A retrospective study.

Authors:  G J Pardos; M A Gallagher
Journal:  Arch Ophthalmol       Date:  1982-10

6.  Stability studies with amphotericin B and amphotericin B methyl ester.

Authors:  D P Bonner; W Mechlinski; C P Schaffner
Journal:  J Antibiot (Tokyo)       Date:  1975-02       Impact factor: 2.649

7.  Optimization of ascitic fluid culture technique.

Authors:  B A Runyon; H N Canawati; E A Akriviadis
Journal:  Gastroenterology       Date:  1988-11       Impact factor: 22.682

8.  Use of a pair of blood culture bottles for sterility testing of corneal organ culture media.

Authors:  P Gain; G Thuret; C Chiquet; A C Vautrin; A Carricajo; S Acquart; J Maugery; G Aubert
Journal:  Br J Ophthalmol       Date:  2001-10       Impact factor: 4.638

9.  Colorimetric indicators of microbial contamination in corneal preservation medium.

Authors:  Y I Chu; R L Penland; K R Wilhelmus
Journal:  Cornea       Date:  2000-07       Impact factor: 2.651

10.  Endophthalmitis following penetrating keratoplasty.

Authors:  A S Leveille; F D McMullan; H D Cavanagh
Journal:  Ophthalmology       Date:  1983-01       Impact factor: 12.079

View more
  11 in total

1.  Corneal endothelial cell therapy: feasibility of cell culture from corneas stored in organ culture.

Authors:  Zhiguo He; Naoki Okumura; Masakazu Sato; Yuya Komori; Makiko Nakahara; Philippe Gain; Noriko Koizumi; Gilles Thuret
Journal:  Cell Tissue Bank       Date:  2021-04-16       Impact factor: 1.522

2.  Validation of the Microbiological Testing of Tissue Preparations Using the BACTEC™ Blood Culture System.

Authors:  Jan Schroeter; Ina Wilkemeyer; Reinhold A Schiller; Axel Pruss
Journal:  Transfus Med Hemother       Date:  2012-11-21       Impact factor: 3.747

3.  Efficiency of blood culture bottles for the fungal sterility testing of corneal organ culture media.

Authors:  G Thuret; A Carricajo; A C Vautrin; H Raberin; S Acquart; O Garraud; P Gain; G Aubert
Journal:  Br J Ophthalmol       Date:  2005-05       Impact factor: 4.638

4.  Detection of contamination during organ culture of the human cornea.

Authors:  Martin Hermel; Sabine Salla; Nicole Hamsley; André Steinfeld; Peter Walter
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2009-09-23       Impact factor: 3.117

5.  Microscopic detection of viable Staphylococcus epidermidis in peri-implant tissue in experimental biomaterial-associated infection, identified by bromodeoxyuridine incorporation.

Authors:  C A N Broekhuizen; M Sta; C M J E Vandenbroucke-Grauls; S A J Zaat
Journal:  Infect Immun       Date:  2010-01-04       Impact factor: 3.441

6.  Method for sterility testing of corneal storage and transport media after removal of interfering antimicrobials: prospective validation study in compliance with the European Pharmacopoeia.

Authors:  Raffaela Mistò; Laura Giurgola; Francesca Pateri; Elisabetta Frigerio; Anna Limongelli; Jana D'Amato Tóthová
Journal:  BMJ Open Ophthalmol       Date:  2017-11-15

7.  Increased sensitivity of microbiological testing of cornea organ culture medium by additional resin treatment.

Authors:  Zemra Skenderi; Laura Giurgola; Claudio Gatto; Jana D'Amato Tóthová; Axel Pruß; Jan Schroeter
Journal:  BMJ Open Ophthalmol       Date:  2018-11-10

8.  Next-generation sequencing for the detection of microorganisms present in human donor corneal preservation medium.

Authors:  Mohit Parekh; Davide Borroni; Vito Romano; Stephen B Kaye; Davide Camposampiero; Diego Ponzin; Stefano Ferrari
Journal:  BMJ Open Ophthalmol       Date:  2019-04-20

9.  Evaluation of interface quality in organ-cultured lamellar corneal transplants.

Authors:  Armin Wolf; Burkhard von Jagow; Daniel Kook; Elisabeth M Messmer; Carlo A Lackerbauer; Anselm Kampik; Thomas Kohnen; Martin Grueterich
Journal:  Clin Ophthalmol       Date:  2012-07-17

10.  Evaluation of the HB&L System for the Microbiological Screening of Storage Medium for Organ-Cultured Corneas.

Authors:  D Camposampiero; S Grandesso; E Zanetti; S Mazzucato; M Solinas; M Parekh; A C Frigo; M Gion; D Ponzin
Journal:  J Ophthalmol       Date:  2013-08-28       Impact factor: 1.909

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.