Literature DB >> 8060015

Repelling magnets versus superelastic nickel-titanium coils in simultaneous distal movement of maxillary first and second molars.

L Bondemark1, J Kurol, M Bernhold.   

Abstract

Eighteen subjects, aged 12.5 to 18.3 years, with Class II malocclusion, deep overbite and moderate space deficiency in the maxilla were treated orthodontically using repelling rare earth magnets on one side and superelastic nickel-titanium coils on the contralateral side for simultaneous distalization of maxillary first and second molars. The force values of the magnets and the coils were calibrated to 225g at the start of treatment and when reactivation was performed every fourth week. Tooth movement was analyzed by measuring dental casts, lateral photographs of dental casts, and lateral skull radiographs before and after 6 months of treatment. Mean distal molar movement was 3.2 mm for the supercoils and 2.2 mm for the magnets. Mean reduction of the overbite was 3.6 mm. Complaints of discomfort were more frequent for the magnet sides. The results indicate that superelastic coils are more effective than repelling rare earth magnets in molar distalization.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 8060015     DOI: 10.1043/0003-3219(1994)064<0189:RMVSNC>2.0.CO;2

Source DB:  PubMed          Journal:  Angle Orthod        ISSN: 0003-3219            Impact factor:   2.079


  10 in total

1.  Class II correction with magnets and superelastic coils followed by straight-wire mechanotherapy. Occlusal changes during and after dental therapy.

Authors:  L Bondemark; J Kurol
Journal:  J Orofac Orthop       Date:  1998       Impact factor: 1.938

2.  Comparison of K-loop Molar Distalization with that of Pendulum Appliance - A Prospective Comparative Study.

Authors:  Nagam Reddy Shashidhar; S Rama Koteswara Reddy; Madhukar Reddy Rachala
Journal:  J Clin Diagn Res       Date:  2016-06-01

3.  Effects of maxillary molar distalization with Zygoma-Gear Appliance.

Authors:  Metin Nur; Mehmet Bayram; Mevlut Celikoglu; Dogan Kilkis; Ali Alper Pampu
Journal:  Angle Orthod       Date:  2011-12-08       Impact factor: 2.079

4.  Treatment effects of quad-helix on the eruption pattern of maxillary second molars.

Authors:  Yoshiki Kobayashi; Isao Shundo; Toshiya Endo
Journal:  Angle Orthod       Date:  2011-12-08       Impact factor: 2.079

5.  Comparison of two implant-supported molar distalization systems.

Authors:  Cagla Sar; Burcak Kaya; Omur Ozsoy; Ayca Arman Özcirpici
Journal:  Angle Orthod       Date:  2012-10-29       Impact factor: 2.079

Review 6.  Efficiency of molar distalization associated with second and third molar eruption stage.

Authors:  Carlos Flores-Mir; Lisa McGrath; Giseon Heo; Paul W Major
Journal:  Angle Orthod       Date:  2012-11-20       Impact factor: 2.079

7.  Fabrication and evaluation of a noncompliant molar distalizing appliance: bonded molar distalizer.

Authors:  A Sodagar; M S Ahmad Akhoundi; A Rafighii; S Arab
Journal:  J Dent (Tehran)       Date:  2011-09-30

8.  Comparative evaluation of molar distalization therapy with erupted second molar: Segmented versus Quad Pendulum appliance.

Authors:  Alberto Caprioglio; Mauro Cozzani; Mattia Fontana
Journal:  Prog Orthod       Date:  2014-08-06       Impact factor: 2.750

9.  Clinical evaluation of neodymium-iron-boron (Ne2Fe14B) rare earth magnets in the treatment of mid line diastemas.

Authors:  Mandava Prasad; Mitta Manoj-Kumar; Singaraju Gowri-Sankar; Nellore Chaitanya; Ganugapanta Vivek-Reddy; Nettam Venkatesh
Journal:  J Clin Exp Dent       Date:  2016-04-01

10.  Comparison of one versus two maxillary molars distalization with iPanda: a finite element analysis.

Authors:  Kamontip Sujaritwanid; Boonsiva Suzuki; Eduardo Yugo Suzuki
Journal:  Prog Orthod       Date:  2021-05-03       Impact factor: 2.750

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.