Literature DB >> 23106546

Comparison of two implant-supported molar distalization systems.

Cagla Sar1, Burcak Kaya, Omur Ozsoy, Ayca Arman Özcirpici.   

Abstract

OBJECTIVE: To examine skeletal, dental, and soft tissue effects of the Miniscrew Implant Supported Distalization System (MISDS) and the Bone-Anchored Pendulum Appliance (BAPA).
MATERIALS AND METHODS: Among 28 patients displaying Angle Class II malocclusion, 14 patients with a mean age of 14.8 ± 3.6 years treated with MISDS were included in the first group, and 14 patients with a mean age of 14.5 ± 1.5 years treated with BAPA were included in the second group. The pretreatment and posttreatment lateral cephalograms were analyzed. Statistical evaluation was carried out using the paired Shapiro-Wilk test, the paired-sample t-test, and the unpaired t-test.
RESULTS: Upper posterior teeth were distalized successfully in both groups. Nearly bodily distalization was seen in the MISDS group, whereas significant distal tipping of the upper first molars was observed in the BAPA group (P < .001). There were no statistically significant changes in the sagittal position of the maxilla and mandible and in the position of the upper incisors as a result of treatment in either group.
CONCLUSIONS: Both methods provided absolute anchorage for distalization of posterior teeth; however, almost translatory distal movement was encountered in the MISDS group, and substantial distal tipping of the maxillary molars accompanied distalization in the BAPA group.

Entities:  

Mesh:

Year:  2012        PMID: 23106546      PMCID: PMC8763062          DOI: 10.2319/080512-630.1

Source DB:  PubMed          Journal:  Angle Orthod        ISSN: 0003-3219            Impact factor:   2.079


  22 in total

1.  Unilateral distal molar movement with an implant-supported distal jet appliance.

Authors:  A I Karaman; F A Basciftci; O Polat
Journal:  Angle Orthod       Date:  2002-04       Impact factor: 2.079

2.  Evaluation of the Jones jig appliance for distal molar movement.

Authors:  C D Brickman; P K Sinha; R S Nanda
Journal:  Am J Orthod Dentofacial Orthop       Date:  2000-11       Impact factor: 2.650

3.  Maxillary molar distalization with a bone-anchored pendulum appliance.

Authors:  Beyza Hancioğlu Kircelli; Zafer Ozgür Pektaş; Cem Kircelli
Journal:  Angle Orthod       Date:  2006-07       Impact factor: 2.079

4.  Osseointegrated implants with pendulum springs for maxillary molar distalization: a cephalometric study.

Authors:  Gökhan Onçağ; Ozlem Seçkin; Banu Dinçer; Fatih Arikan
Journal:  Am J Orthod Dentofacial Orthop       Date:  2007-01       Impact factor: 2.650

5.  Comparison of 2 distalization systems supported by intraosseous screws.

Authors:  Ibrahim Erhan Gelgor; Ali Ihya Karaman; Tamer Buyukyilmaz
Journal:  Am J Orthod Dentofacial Orthop       Date:  2007-02       Impact factor: 2.650

6.  Efficiency of a skeletonized distal jet appliance supported by miniscrew anchorage for noncompliance maxillary molar distalization.

Authors:  Gero S M Kinzinger; Norbert Gülden; Faruk Yildizhan; Peter R Diedrich
Journal:  Am J Orthod Dentofacial Orthop       Date:  2009-10       Impact factor: 2.650

7.  The use of magnets to move molars distally.

Authors:  A A Gianelly; A S Vaitas; W M Thomas
Journal:  Am J Orthod Dentofacial Orthop       Date:  1989-08       Impact factor: 2.650

8.  Dentoalveolar and skeletal changes associated with the pendulum appliance.

Authors:  T J Bussick; J A McNamara
Journal:  Am J Orthod Dentofacial Orthop       Date:  2000-03       Impact factor: 2.650

9.  A comparison of two intraoral molar distalization appliances: distal jet versus pendulum.

Authors:  Patricia P Chiu; James A McNamara; Lorenzo Franchi
Journal:  Am J Orthod Dentofacial Orthop       Date:  2005-09       Impact factor: 2.650

10.  Pendulum appliances with 2 anchorage designs: conventional anchorage vs bone anchorage.

Authors:  Omür Polat-Ozsoy; Beyza Hancioğlu Kircelli; Ayça Arman-Ozçirpici; Z Ozgür Pektaş; Sina Uçkan
Journal:  Am J Orthod Dentofacial Orthop       Date:  2008-03       Impact factor: 2.650

View more
  10 in total

1.  Maxillary molar distalization with miniscrew-supported appliances in Class II malocclusion: A systematic review.

Authors:  Roshan Noor Mohamed; Sakeenabi Basha; Yousef Al-Thomali
Journal:  Angle Orthod       Date:  2018-04-17       Impact factor: 2.079

2.  Evaluation of the effects of the hybrid Pendulum in comparison with the conventional Pendulum appliance.

Authors:  Erdal Bozkaya; Tuba Tortop; Sema Yüksel; Emine Kaygısız
Journal:  Angle Orthod       Date:  2019-10-23       Impact factor: 2.079

3.  Evaluation of Dentoalveolar and Dentofacial Effects of a Mini-Screw-Anchored Pendulum Appliance in Maxillary Molar Distalization.

Authors:  Mümin Kırcalı; Alime Sema Yüksel
Journal:  Turk J Orthod       Date:  2018-12-01

4.  Analysis of midpalatal miniscrew-assisted maxillary molar distalization patterns with simultaneous use of fixed appliances: A preliminary study.

Authors:  Su-Jung Mah; Ji-Eun Kim; Eun Jin Ahn; Jong-Hyun Nam; Ji-Young Kim; Yoon-Goo Kang
Journal:  Korean J Orthod       Date:  2016-01-25       Impact factor: 1.372

5.  Bilateral en-masse distalization of maxillary posterior teeth with skeletal anchorage: a case report.

Authors:  Saeed Noorollahian; Shiva Alavi; Farinaz Shirban
Journal:  Dental Press J Orthod       Date:  2016-06

6.  Class II correction by maxillary en masse distalization using a completely customized lingual appliance and a novel mini-screw anchorage concept - preliminary results.

Authors:  Frauke Beyling; Elisabeth Klang; Eva Niehoff; Rainer Schwestka-Polly; Hans-Joachim Helms; Dirk Wiechmann
Journal:  Head Face Med       Date:  2021-06-29       Impact factor: 2.151

7.  Comparative evaluation of molar distalization therapy using pendulum and distal screw appliances.

Authors:  Alberto Caprioglio; Alessandra Cafagna; Mattia Fontana; Mauro Cozzani
Journal:  Korean J Orthod       Date:  2015-07-24       Impact factor: 1.372

8.  Three-dimensional analysis of the distal movement of maxillary 1st molars in patients fitted with mini-implant-aided trans-palatal arches.

Authors:  Amirfarhang Miresmaeili; Ahmad Sajedi; Abbas Moghimbeigi; Nasrin Farhadian
Journal:  Korean J Orthod       Date:  2015-09-23       Impact factor: 1.372

9.  Changes consequent to maxillary molar distalization with the bone-anchored pendulum appliance.

Authors:  Aldo Otazú Cambiano; Guilherme Janson; Acácio Fuziy; Daniela Gamba Garib; Diego Coelho Lorenzoni
Journal:  J Orthod Sci       Date:  2017 Oct-Dec

10.  Comparison of treatment effects between four premolar extraction and total arch distalization using the modified C-palatal plate.

Authors:  Sung Youn Jo; Mohamed Bayome; Justyn Park; Hee Jin Lim; Yoon-Ah Kook; Seong Ho Han
Journal:  Korean J Orthod       Date:  2018-07-06       Impact factor: 1.372

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.