INTRODUCTION: Molar distalization is the non extraction method of managing Class II malocclusions. AIM: The purpose of this study was to evaluate the skeletal and dentoalveolar effects of maxillary molar distalization with K-loop appliance, and to compare these effects with that of pendulum group.
MATERIALS AND METHODS: Class I and dental Class II malocclusions were divided into two groups of 15 each: In Group 1 (nine females and six males; mean age, 16.0±2.6 years) patients were treated with K-Loop molar distalization supported palatally by Nance button, while in Group 2 (seven females and eight males; mean age, 15.4±4.7 years), the patients were treated with conventional pendulum appliance. Standardized lateral cephalograms were taken at the beginning of treatment (T0) and at the end of molar distalization (T1) and the changes were statistically analyzed with paired t-test.
RESULTS: The results showed no statistically significant difference in the amount of molar distalization in either of the appliance groups: the mean amount of molar distal movement of 5.1±0.8 mm and 4.93±1.68 mm was observed in the Group 1 and 2 respectively. The incisors moved mesially by 1.3±0.63 mm in Group 1 and 1.57±0.58 mm in Group 2.
CONCLUSION: K-Loop molar distalizing appliance has similar skeletal and dentoalveolar effects as that of pendulum appliance, with the advantages of simple yet efficient to control the moment-force ratio to produce all types of tooth movements and also requires minimal patient co-operation.

Entities:  

Keywords:  Class II malocclusion; Dento-aveolar effects; Non extraction treatment; Vertical dimension

Year:  2016        PMID: 27504403      PMCID: PMC4963763          DOI: 10.7860/JCDR/2016/19560.7931

Source DB:  PubMed          Journal:  J Clin Diagn Res        ISSN: 0973-709X


  14 in total

1.  The distal jet for upper molar distalization.

Authors:  A Carano; M Testa
Journal:  J Clin Orthod       Date:  1996-07

2.  Modified Nance appliance for unilateral molar distalization.

Authors:  T J Reiner
Journal:  J Clin Orthod       Date:  1992-07

3.  Molar distalization with repelling magnets.

Authors:  T Itoh; T Tokuda; S Kiyosue; T Hirose; M Matsumoto; S J Chaconas
Journal:  J Clin Orthod       Date:  1991-10

4.  Rapid Class II molar correction with an open-coil jig.

Authors:  R D Jones; J M White
Journal:  J Clin Orthod       Date:  1992-10

5.  The pendulum appliance for Class II non-compliance therapy.

Authors:  J J Hilgers
Journal:  J Clin Orthod       Date:  1992-11

6.  Distal molar movement using the pendulum appliance. Part 1: Clinical and radiological evaluation.

Authors:  F K Byloff; M A Darendeliler
Journal:  Angle Orthod       Date:  1997       Impact factor: 2.079

7.  Distalization of molars with repelling magnets.

Authors:  A A Gianelly; A S Vaitas; W M Thomas; D G Berger
Journal:  J Clin Orthod       Date:  1988-01

8.  Molar and incisor changes with Wilson rapid molar distalization.

Authors:  D S Muse; M J Fillman; W J Emmerson; R D Mitchell
Journal:  Am J Orthod Dentofacial Orthop       Date:  1993-12       Impact factor: 2.650

9.  Repelling magnets versus superelastic nickel-titanium coils in simultaneous distal movement of maxillary first and second molars.

Authors:  L Bondemark; J Kurol; M Bernhold
Journal:  Angle Orthod       Date:  1994       Impact factor: 2.079

10.  Skeletal versus conventional intraoral anchorage for the treatment of class II malocclusion: dentoalveolar and skeletal effects.

Authors:  Lisa Mariani; Giuliano Maino; Alberto Caprioglio
Journal:  Prog Orthod       Date:  2014-07-30       Impact factor: 2.750

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.