Literature DB >> 8051264

Evaluation of rapid test for detection of antibody to human immunodeficiency virus type 1 and type 2.

P J Asihene1, R L Kline, M W Moss, A V Carella, T C Quinn.   

Abstract

The Genie HIV-1/HIV-2 rapid assay was compared with an enzyme-linked immunosorbent assay and Western blot (immunoblot) by using 540 serum specimens from four different populations. The Genie HIV-1/HIV-2 assay was easy to perform, required no equipment, provided visual results within 10 min, and demonstrated excellent sensitivity and specificity compared with the Western blot.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 8051264      PMCID: PMC263692          DOI: 10.1128/jcm.32.5.1341-1342.1994

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  4 in total

1.  Performance and cost-effectiveness of a dual rapid assay system for screening and confirmation of human immunodeficiency virus type 1 seropositivity.

Authors:  F A Spielberg; C M Kabeya; T C Quinn; R W Ryder; N K Kifuani; J Harris; T R Bender; W L Heyward; M R Tam; K Auditore-Hargreaves
Journal:  J Clin Microbiol       Date:  1990-02       Impact factor: 5.948

2.  Field evaluation of alternative HIV testing strategy with a rapid immunobinding assay and an agglutination assay.

Authors:  S W Mitchell; S Mboup; J Mingle; D Sambe; P Tukei; K Milenge; J Nyamongo; O K Mubarak; J L Sankale; D S Hanson
Journal:  Lancet       Date:  1991-06-01       Impact factor: 79.321

3.  Rapid and specific diagnosis of HIV-1 and HIV-2 infections: an evaluation of testing strategies.

Authors:  K M De Cock; A Porter; J Kouadio; M Maran; E Gnaore; G Adjorlolo; M F Lafontaine; G Bretton; G M Damet; K Odehouri
Journal:  AIDS       Date:  1990-09       Impact factor: 4.177

4.  Field testing and comparative evaluation of rapid, visually read screening assays for antibody to human immunodeficiency virus.

Authors:  F Spielberg; C M Kabeya; R W Ryder; N K Kifuani; J Harris; T R Bender; W L Heyward; T C Quinn
Journal:  Lancet       Date:  1989-03-18       Impact factor: 79.321

  4 in total
  4 in total

1.  Evaluation of United States-licensed human immunodeficiency virus immunoassays for detection of group M viral variants.

Authors:  W H Koch; P S Sullivan; C Roberts; K Francis; R Downing; T D Mastro; J Nkengasong; D Hu; S Masciotra; C Schable; R B Lal
Journal:  J Clin Microbiol       Date:  2001-03       Impact factor: 5.948

2.  A simple whole-blood test for detecting antibodies to human immunodeficiency virus.

Authors:  W Schramm; S E Wade; G Barriga Angulo; P Castillo Torres; A Burgess-Cassler
Journal:  Clin Diagn Lab Immunol       Date:  1998-03

3.  Evaluation and diagnostic usefulness of domestic and imported enzyme-linked immunosorbent assays for detection of human immunodeficiency virus type 1 antibody in India.

Authors:  H Syed Iqbal; Suniti Solomon; K G Murugavel; Sunil Suhas Solomon; P Balakrishnan
Journal:  Clin Diagn Lab Immunol       Date:  2005-12

4.  Diagnosis of human immunodeficiency virus type 1 infection with different subtypes using rapid tests.

Authors:  S Phillips; T C Granade; C P Pau; D Candal; D J Hu; B S Parekh
Journal:  Clin Diagn Lab Immunol       Date:  2000-07
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.