Literature DB >> 3323229

Multicenter comparison of MicroScan and BACTEC blood culture systems.

B Wasilauskas1, R Gay, P Zwadyk, M Pfaller, F Koontz.   

Abstract

Recently, MicroScan (Baxter MicroScan Div., W. Sacramento, Calif.) introduced a radiolabeled-blood-culture system that is compatible with the BACTEC 460 (Johnston Laboratories, Inc., Towson, Md.). A multicenter blood culture study was initiated to evaluate this new system. Approximately 20 ml of blood was obtained from each patient and divided equally between BACTEC and MicroScan bottles which were incubated and processed identically. Aerobic bottles were examined twice on days 1 and 2 and once on days 3, 4, 5, 6, and 7. Anaerobic bottles were examined once a day for 7 days. There were 3,451 cultures evaluated, and 414 of these subsequently grew microorganisms. Of these positive cultures, 64 were judged to be contaminated. Of the remaining 350 positive cultures, 253 grew in both systems, 54 grew in BACTEC bottles only, and 43 grew in MicroScan bottles only. The average times to detect positive cultures were 1.8 and 2.1 days by the BACTEC and the MicroScan systems, respectively. No significant difference in the number or kind of organisms recovered or in the detection times for positive cultures was observed between the two blood-culturing systems.

Entities:  

Mesh:

Year:  1987        PMID: 3323229      PMCID: PMC269487          DOI: 10.1128/jcm.25.12.2355-2358.1987

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  8 in total

1.  Evaluation of radiometric system for detecting bacteremia.

Authors:  E D Renner; L A Gatheridge; J A Washington
Journal:  Appl Microbiol       Date:  1973-09

2.  Rapid detection of bacteremia by a radiometric system. A clinical evaluation.

Authors:  K Brooks; T Sodeman
Journal:  Am J Clin Pathol       Date:  1974-06       Impact factor: 2.493

3.  Automated radiometric detection of bacteria in 2,967 blood cultures.

Authors:  H J DeBlanc; F DeLand; H N Wagner
Journal:  Appl Microbiol       Date:  1971-11

4.  Nosocomial septicemia due to multiply antibiotic-resistant Staphylococcus epidermidis.

Authors:  G D Christensen; A L Bisno; J T Parisi; B McLaughlin; M G Hester; R W Luther
Journal:  Ann Intern Med       Date:  1982-01       Impact factor: 25.391

5.  Hospital-acquired bloodstream infections with Staphylococcus epidermidis. Review of 100 cases.

Authors:  S Ponce de Leon; R P Wenzel
Journal:  Am J Med       Date:  1984-10       Impact factor: 4.965

6.  Coagulase-negative staphylococcal bacteremia in patients receiving immunosuppressive therapy.

Authors:  D J Winston; D V Dudnick; M Chapin; W G Ho; R P Gale; W J Martin
Journal:  Arch Intern Med       Date:  1983-01

7.  Determination of the optimum incubation period of blood culture broths for the detection of clinically significant septicemia.

Authors:  P R Murray
Journal:  J Clin Microbiol       Date:  1985-04       Impact factor: 5.948

8.  Comparison of two liquid blood culture media containing sodium polyanethole sulfonate: tryptic soy and Columbia.

Authors:  M Hall; E Warren; J A Washington
Journal:  Appl Microbiol       Date:  1974-04
  8 in total
  5 in total

1.  Assessment of the BACTEC NR660 blood culture system for the detection of bacteremia in young children.

Authors:  J D Anderson; C Trombley; N Cimolai
Journal:  J Clin Microbiol       Date:  1989-04       Impact factor: 5.948

Review 2.  Detection of bloodstream infections in children.

Authors:  J M Campos
Journal:  Eur J Clin Microbiol Infect Dis       Date:  1989-09       Impact factor: 3.267

3.  Biographical Feature: Franklin P. Koontz, Ph.D., D(ABMM), F(AAM).

Authors:  Erik Munson
Journal:  J Clin Microbiol       Date:  2020-02-24       Impact factor: 5.948

4.  Evaluation of BACTEC 9240 blood culture system by using high-volume aerobic resin media.

Authors:  L D Schwabe; R B Thomson; K K Flint; F P Koontz
Journal:  J Clin Microbiol       Date:  1995-09       Impact factor: 5.948

5.  Comparison of Difco ESP and Organon Teknika BacT/Alert continuous-monitoring blood culture systems.

Authors:  P Zwadyk; C L Pierson; C Young
Journal:  J Clin Microbiol       Date:  1994-05       Impact factor: 5.948

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.