Literature DB >> 8037391

The pulse oximetry gap in carbon monoxide intoxication.

R G Buckley1, S E Aks, J L Eshom, R Rydman, J Schaider, P Shayne.   

Abstract

STUDY
OBJECTIVE: Pulse oximetry has been reported to be falsely elevated in the presence of carbon monoxide (CO). However, the degree to which pulse oximetry overestimates measured oxyhemoglobin saturation (O2Hb) has not been investigated in patients with CO exposure. This study quantifies the effect of CO on pulse oximetry and O2Hb in a series of patients with elevated carboxyhemoglobin (COHb) levels.
METHODS: A prospective case series of 25 pulse oximetry measurements, with concurrent arterial blood gas sampling, were obtained on 16 adults with CO exposure.
RESULTS: COHb levels (mean, 16.1%; SD, 11.6%; range, 2.2% to 44%) did not significantly correlate with pulse oximetry saturation (mean, 97.7%; SD, 1.5%; range 96% to 100%) (r = .45; P = .1 [NS]). Compared with COHb, a pulse oximetry gap (mean, 17.5%; SD, 1.5%; range, 2.3% to 42%), defined as pulse oximetry saturation minus O2Hb, yielded a linear regression model: pulse oximetry gap = 1.82 + 0.94 x COHb (SEM = 0.07; F = 204; R2 = .90; P < .0001).
CONCLUSION: Oxygen saturation as measured by pulse oximetry failed to decrease to less than 96% despite COHb levels as high as 44%. Regression between the pulse oximetry gap and COHb suggests that pulse oximetry overestimates O2Hb by the amount of COHb present. Pulse oximetry is unreliable in estimating O2Hb saturation in CO-exposed patients and should be interpreted with caution when used to estimate oxygen saturation in smokers.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 8037391     DOI: 10.1016/s0196-0644(94)70137-7

Source DB:  PubMed          Journal:  Ann Emerg Med        ISSN: 0196-0644            Impact factor:   5.721


  9 in total

Review 1.  Carbon monoxide poisoning: an update.

Authors:  M Turner; M R Hamilton-Farrell; R J Clark
Journal:  J Accid Emerg Med       Date:  1999-03

2.  Correlation Between PaO2/FIO2 and Peripheral Capillary Oxygenation/FIO2 in Burned Children With Smoke Inhalation Injury.

Authors:  Janos Cambiaso-Daniel; Charles D Voigt; Eric Rivas; Gabriel Hundeshagen; Omar Nunez-Lopez; Lars-Peter Kamolz; Michaela Sljivich; Linda E Sousse; David N Herndon; Oscar E Suman; Michael P Kinsky; Ronald P Mlcak
Journal:  Pediatr Crit Care Med       Date:  2017-10       Impact factor: 3.624

3.  Accuracy of carboxyhemoglobin detection by pulse CO-oximetry during hypoxemia.

Authors:  John R Feiner; Mark D Rollins; Jeffrey W Sall; Helge Eilers; Paul Au; Philip E Bickler
Journal:  Anesth Analg       Date:  2013-03-11       Impact factor: 5.108

4.  Comparison of two new generation pulse oximeters with arterial oxygen saturation in critically ill children.

Authors:  Bipin Jose; Rakesh Lodha; S K Kabra
Journal:  Indian J Pediatr       Date:  2014-03-15       Impact factor: 1.967

5.  Pulse oximetry.

Authors: 
Journal:  Crit Care       Date:  1999       Impact factor: 9.097

Review 6.  Pulse oximetry.

Authors:  Amal Jubran
Journal:  Crit Care       Date:  2015-07-16       Impact factor: 9.097

7.  Pulse oximeter measurement error of oxygen saturation in patients with SARS-CoV-2 infection stratified by smoking status.

Authors:  Colin J Crooks; Joe West; Joanne R Morling; Mark Simmonds; Irene Juurlink; Steve Briggs; Simon Cruickshank; Susan Hammond-Pears; Dominick Shaw; Timothy R Card; Andrew W Fogarty
Journal:  Eur Respir J       Date:  2022-10-13       Impact factor: 33.795

8.  Ambulatory pulse oximetry monitoring in Japanese COPD outpatients not receiving oxygen therapy.

Authors:  Seigo Minami; Suguru Yamamoto; Yoshitaka Ogata; Takeshi Nakatani; Yoshiko Takeuchi; Masanari Hamaguchi; Taro Koba; Kiyoshi Komuta
Journal:  Multidiscip Respir Med       Date:  2014-04-17

9.  Individual variations and sex differences in hemodynamics with percutaneous arterial oxygen saturation (SpO2) in young Andean highlanders in Bolivia.

Authors:  Takayuki Nishimura; Juan Ugarte; Mayumi Ohnishi; Mika Nishihara; Guillermo Alvarez; Yoshiki Yasukochi; Hideki Fukuda; Kazuhiko Arima; Shigeki Watanuki; Victor Mendoza; Kiyoshi Aoyagi
Journal:  J Physiol Anthropol       Date:  2020-10-07       Impact factor: 2.867

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.