Literature DB >> 8025810

WET, a T1- and B1-insensitive water-suppression method for in vivo localized 1H NMR spectroscopy.

R J Ogg1, P B Kingsley, J S Taylor.   

Abstract

Suppression of the water signal during 1H magnetic resonance spectroscopy by repeated sequences of a frequency-selective radiofrequency pulse and a gradient dephasing pulse requires nulling of the longitudinal component of the water magnetization and is therefore affected by T1 relaxation, RF-pulse flip angles (which depend on B1), and sequence timing. In in vivo applications, T1 and B1 inhomogeneity within the sample may cause spatially inhomogeneous water suppression. An improved water-suppression technique called WET (water suppression enhanced through T1 effects), developed from a Bloch equation analysis of the longitudinal magnetization over the T1 and B1 ranges of interest, achieves T1- and B1-insensitive suppression with four RF pulses, each having a numerically optimized flip angle. Once flip angles have been optimized for a given sequence, time-consuming flip-angle adjustments during clinical examinations are eliminated. This water-suppression technique was characterized with respect to T1 variations, B1 variations, off-resonance effects, and partial saturation effects and was compared to similar techniques. Effective water suppression has been achieved with this new technique in single-voxel spectroscopy examinations of more than 50 brain tumor patients at 1.5 T.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 8025810     DOI: 10.1006/jmrb.1994.1048

Source DB:  PubMed          Journal:  J Magn Reson B        ISSN: 1064-1866


  210 in total

1.  In vivo proton MR spectroscopy of pancreatic neuroendocrine tumors in a multiple endocrine neoplasia type 1 conditional knockout mouse model.

Authors:  Min-Hui Cui; Craig A Branch; Sean M Cahill; Thomas J Quinn; Asha Adem; Steven K Libutti; Ziqiang Yuan
Journal:  Magn Reson Med       Date:  2014-11-13       Impact factor: 4.668

2.  Multislice ¹H MRSI of the human brain at 7 T using dynamic B₀ and B₁ shimming.

Authors:  Vincent O Boer; Dennis W J Klomp; Christoph Juchem; Peter R Luijten; Robin A de Graaf
Journal:  Magn Reson Med       Date:  2011-12-12       Impact factor: 4.668

Review 3.  MR spectroscopy and spectroscopic imaging of the brain.

Authors:  He Zhu; Peter B Barker
Journal:  Methods Mol Biol       Date:  2011

4.  Preparation, characterization, and NMR spectroscopy of encapsulated proteins dissolved in low viscosity fluids.

Authors:  Charles R Babu; Peter F Flynn; A Joshua Wand
Journal:  J Biomol NMR       Date:  2003-04       Impact factor: 2.835

5.  Transmit/receive headcoil for optimal 1H MR spectroscopy of the brain in paediatric patients at 3T.

Authors:  D W J Klomp; M van der Graaf; M A A P Willemsen; Y M van der Meulen; A P M Kentgens; A Heerschap
Journal:  MAGMA       Date:  2004-05-24       Impact factor: 2.310

Review 6.  Magnetic resonance perfusion imaging without contrast media.

Authors:  Petros Martirosian; Andreas Boss; Christina Schraml; Nina F Schwenzer; Hansjörg Graf; Claus D Claussen; Fritz Schick
Journal:  Eur J Nucl Med Mol Imaging       Date:  2010-08       Impact factor: 9.236

7.  Proton MR spectroscopy in a 1T open MR imaging system.

Authors:  C G Filippi; T Pace; T G Perkins; J B Murdoch; T Andrews
Journal:  AJNR Am J Neuroradiol       Date:  2010-12-16       Impact factor: 3.825

8.  J-refocused coherence transfer spectroscopic imaging at 7 T in human brain.

Authors:  J W Pan; N Avdievich; H P Hetherington
Journal:  Magn Reson Med       Date:  2010-11       Impact factor: 4.668

9.  Correlated spectroscopic imaging of calf muscle in three spatial dimensions using group sparse reconstruction of undersampled single and multichannel data.

Authors:  Neil E Wilson; Brian L Burns; Zohaib Iqbal; M Albert Thomas
Journal:  Magn Reson Med       Date:  2015-09-18       Impact factor: 4.668

10.  Removal of nuisance signals from limited and sparse 1H MRSI data using a union-of-subspaces model.

Authors:  Chao Ma; Fan Lam; Curtis L Johnson; Zhi-Pei Liang
Journal:  Magn Reson Med       Date:  2015-03-11       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.