Literature DB >> 7996092

Radiographic determination of canal length direct digital radiography versus conventional radiography.

R T Hedrick1, S B Dove, D D Peters, W D McDavid.   

Abstract

This research compared the length determination images produced by Trophy and Regam direct digital radiographic systems with conventional E-speed radiographs. Size #15 K files were placed in the canals of 19 teeth of cadaver specimens and radiographed in a geometrically standardized bench device. Three evaluators estimated the length adjustment necessary to position the file at the apex. The mean estimated adjustment lengths were compared with the true, anatomically determined adjustment lengths. Statistical analysis with analysis of variance and the Student-Newman-Keuls test indicated no significant difference between direct digital thermal print images and conventional radiographs (p > 0.10). Length adjustment estimates with conventional radiographs were significantly more accurate than Regam high-resolution computer monitor images (p < 0.01). Additionally, it was determined that length adjustment estimates were significantly more accurate when the file was placed short of the apex (p < 0.001). The clinical relevance of these differences is discussed.

Mesh:

Year:  1994        PMID: 7996092     DOI: 10.1016/s0099-2399(06)80093-2

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  8 in total

1.  The accuracy of digital radiography in orthopaedic applications.

Authors:  John R Fowler; Asif M Ilyas
Journal:  Clin Orthop Relat Res       Date:  2010-10-23       Impact factor: 4.176

2.  The use of high-resolution digital imaging technology for small diameter K-file length determination in endodontics.

Authors:  Bart Vandenberghe; Marius Bud; Asti Sutanto; Reinhilde Jacobs
Journal:  Clin Oral Investig       Date:  2009-05-19       Impact factor: 3.573

3.  A Comparison of intra-oral digital imaging modalities: Charged Couple Device versus Storage Phosphor Plate.

Authors:  A Anas; Jm Asaad; Ka Tarboush
Journal:  Int J Health Sci (Qassim)       Date:  2010-11

4.  Length of endodontic files measured in digital radiographs with and without noise-suppression filters: an ex-vivo study.

Authors:  D D Brüllmann; B Röhrig; S L Sulayman; R Schulze
Journal:  Dentomaxillofac Radiol       Date:  2011-03       Impact factor: 2.419

5.  Direct digital radiography versus conventional radiography for estimation of canal length in curved canals.

Authors:  Seiedeh Tahereh Mohtavipour; Zahra Dalili; Nasim Gheshlaghi Azar
Journal:  Imaging Sci Dent       Date:  2011-03-26

6.  Digital radiography for determination of primary tooth length: in vivo and ex vivo studies.

Authors:  Maria D Basso; Fabiano Jeremias; Rita C L Cordeiro; Lourdes Santos-Pinto
Journal:  ScientificWorldJournal       Date:  2015-02-23

7.  Evaluation of the effects of processing delays and protective plastic cases on image quality of a photostimulable phosphor plate system.

Authors:  Clóvis Monteiro Bramante; Alexandre Silva Bramante; Rogério Emílio de Souza; Ivaldo Gomes Moraes; Norberti Bernardineli; Roberto Brandão Garcia
Journal:  J Appl Oral Sci       Date:  2008 Sep-Oct       Impact factor: 2.698

8.  Comparison of the accuracy of conventional and digital radiography in root canal working length determination: An invitro study.

Authors:  Mohammad Mahdi Yaghooti Khorasani; Hamed Ebrahimnejad
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2017-09-20
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.