Attenuation in high-energy x-ray beams.

B E Bjärngard1, H Shackford.   

Abstract

Attenuation factors in water have been measured by a narrow-beam technique in various portions of x-ray beams with nominal energies of 6 and 25 MV, with and without a wedge in the beam. The results were analyzed in terms of an attenuation coefficient mu for small water thicknesses and a beam-hardening coefficient eta that describes the change in attenuation per unit depth. The variation of mu within the field was significant, about 0.5% per centimeter at 6 MV and 0.8% per centimeter at 25 MV for open beams. The heavy wedge used in these experiments caused significant (about 10%) beam hardening at 6 MV, softened the beam somewhat at 25 MV, and increased the variation of mu within the field to 3%-5%. These effects should be taken into account in dose calculations, and correction factors can be designed based on the variation of mu with off-axis radius for open beams and with off-axis position for wedged beams. The experimental technique, based on two measurements with the beam going through a water tank with either 26- or 50-cm path length, was simple and highly reproducible. The beam hardening with depth in water, i.e., the value of eta, was readily determined but found to be clinically insignificant.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 7968838     DOI: 10.1118/1.597349

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  5 in total

1.  An empirical model of diagnostic x-ray attenuation under narrow-beam geometry.

Authors:  Kelsey B Mathieu; S Cheenu Kappadath; R Allen White; E Neely Atkinson; Dianna D Cody
Journal:  Med Phys       Date:  2011-08       Impact factor: 4.071

2.  Commissioning compensator-based IMRT on the Pinnacle treatment planning system.

Authors:  Daniel Opp; Kenneth Forster; Vladimir Feygelman
Journal:  J Appl Clin Med Phys       Date:  2011-03-08       Impact factor: 2.102

3.  An Analytical Method to Calculate Phantom Scatter Factor for Photon Beam Accelerators.

Authors:  Mohammad Javad Tahmasebi Birgani; Nahid Chegeni; Mohammad Ali Behrooz; Marziyeh Bagheri; Amir Danyaei; Azin Shamsi
Journal:  Electron Physician       Date:  2017-01-25

4.  Phantom-based evaluation of dose exposure of ultrafast combined kV-MV-CBCT towards clinical implementation for IGRT of lung cancer.

Authors:  Anna Arns; Manuel Blessing; Jens Fleckenstein; Dzmitry Stsepankou; Judit Boda-Heggemann; Juergen Hesser; Frank Lohr; Frederik Wenz; Hansjoerg Wertz
Journal:  PLoS One       Date:  2017-11-10       Impact factor: 3.240

5.  An Empirical Transmitted EPID Dosimetry Method using a Back-Projection Algorithm.

Authors:  Hashemi S M; Bahreyni M H; Mohammadi M; Nasseri S; Bayani S; Gholamhosseinian H; Salek R; Shahedi F; Momennezhad M
Journal:  J Biomed Phys Eng       Date:  2019-10-01
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.