Effects of left ventricular pressure on sonicated albumin microbubbles: evaluation using an isolated rabbit heart model.

V Mor-Avi1, S G Shroff, K A Robinson, A F Ng, B P Cholley, R H Marcus, R M Lang.   

Abstract

OBJECTIVES: We used an isolated, crystalloid-perfused rabbit heart model to test the hypothesis that the phasic changes in left ventricular contrast are due to bubble compression and decompression during systole and diastole, respectively.
BACKGROUND: Contrast enhancement of the left ventricular cavity has been shown to decrease during ventricular systole. This phenomenon has been attributed to pressure-induced microbubble destruction. Such destruction, if confirmed, would severely confound the quantitative interpretation of contrast echocardiographic data.
METHODS: A fixed volume of contrast solution (5% human albumin and Albunex, approximately 400:1 ratio) was introduced into a latex balloon placed within the left ventricular cavity of an isolated paced rabbit heart preparation (n = 12). Instantaneous left ventricular pressure was measured using a high fidelity microtip catheter and digitized on-line. The beating heart was placed in a water tank, and ultrasound images were obtained using a 7.5-MHz transducer and were recorded and digitized off-line at 12 frames/s. Simultaneously, the pacing signal was used for gated on-line acquisition of end-diastolic frames. A simple theoretic model based on surface tension physical principles was used to predict changes in bubble size and, consequently, the reflection intensity in response to the measured changes in left ventricular pressure.
RESULTS: We found that under peak left ventricular systolic pressures ranging from 89 to 155 mm Hg, 1) end-diastolic videointensity decreased by 8 +/- 6% (mean +/- SD) over 25 consecutive heart beats; and 2) intracyclic variations in measured videointensity were in close agreement with the theoretic calculations: 80.1 +/- 2.9% versus 80.2 +/- 4.6% of diastolic videointensity at systole.
CONCLUSIONS: The major cause of systolic decrease in contrast enhancement is periodic bubble compression (as opposed to bubble destruction) induced by high systolic pressures. The minor progressive decrease in end-diastolic videointensity reflects the degree of instability of Albunex microbubbles under left ventricular pressures. However, the clinical impact of these destructive effects is likely to be only minor because of the rapid transit of microbubbles through the left heart chambers and myocardial microcirculation.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 7963128     DOI: 10.1016/0735-1097(94)90187-2

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  5 in total

Review 1.  Contrast echocardiography 1996. A review.

Authors:  H R Villarraga; D A Foley; S L Mulvagh
Journal:  Tex Heart Inst J       Date:  1996

2.  Quantitative contrast-enhanced ultrasound imaging: a review of sources of variability.

Authors:  M-X Tang; H Mulvana; T Gauthier; A K P Lim; D O Cosgrove; R J Eckersley; E Stride
Journal:  Interface Focus       Date:  2011-05-18       Impact factor: 3.906

3.  Effect of pressure on intracardiac backscatter from microbubbles.

Authors:  Y Deng; C Li; Q Chang
Journal:  J Tongji Med Univ       Date:  2001

4.  Stability of echogenic liposomes as a blood pool ultrasound contrast agent in a physiologic flow phantom.

Authors:  Kirthi Radhakrishnan; Kevin J Haworth; Shao-Ling Huang; Melvin E Klegerman; David D McPherson; Christy K Holland
Journal:  Ultrasound Med Biol       Date:  2012-08-25       Impact factor: 2.998

5.  Contrast-enhanced ultrasound evaluation of renal microcirculation in sheep.

Authors:  Antoine G Schneider; Paolo Calzavacca; Anthony Schelleman; Tim Huynh; Michael Bailey; Clive May; Rinaldo Bellomo
Journal:  Intensive Care Med Exp       Date:  2014-11-26