Literature DB >> 12539591

Effect of pressure on intracardiac backscatter from microbubbles.

Y Deng1, C Li, Q Chang.   

Abstract

The backscatter from sonicated albumin microbubbles (Albunex) was analyzed using acoustic densitometry in an in vitro pulsatile heart model to evaluate the effects of pressure on the backscatter from Albunex, and the cardiac cyclic changes of intracardiac backscatter from sonicated albumin microbubbles in 16 healthy persons were analyzed. It was found that the Albunex microbubbles were compressed in systole and decompressed in diastole, causing corresponding changes of backscatter in cardiac cycle. Although the intensities of backscatter in diastole and systole were related to the concentration of microbubbles, the concentration of microbubbles had no effect on the difference of end-diastolic and end-systolic backscatter. The difference of the backscatter was highly correlated with end-systolic pressure (r = 0.96, P = 0.001). In human studies, we also observed same intracardiac cyclic changes of backscatter from sonicated albumin microbubbles. Our study indicates that it is possible to evaluate the intracardiac pressure non-invasively by analyzing the intracardiac backscatter from the microbubbles with acoustic densitometry.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 12539591     DOI: 10.1007/BF02886444

Source DB:  PubMed          Journal:  J Tongji Med Univ        ISSN: 0257-716X


  7 in total

1.  Intravenous contrast echocardiography with use of sonicated albumin in humans: systolic disappearance of left ventricular contrast after transpulmonary transmission.

Authors:  J R Shapiro; S A Reisner; G S Lichtenberg; R S Meltzer
Journal:  J Am Coll Cardiol       Date:  1990-12       Impact factor: 24.094

2.  Integrated backscatter and digital acquisition during myocardial contrast echocardiography: is there an advantage over conventional echocardiography for intracoronary injections?

Authors:  S Ismail; A R Jayaweera; D M Skyba; J Sklenar; N C Goodman; S Kaul
Journal:  J Am Soc Echocardiogr       Date:  1995 Jul-Aug       Impact factor: 5.251

3.  Effect of static pressure on acoustic transmittance of Albunex microbubble suspensions.

Authors:  A A Brayman; M Azadniv; M W Miller; R S Meltzer
Journal:  J Acoust Soc Am       Date:  1996-04       Impact factor: 1.840

4.  Quantitation of echo-contrast effects.

Authors:  S M Powsner; M W Keller; J Saniie; S B Feinstein
Journal:  Am J Physiol Imaging       Date:  1986

5.  Effect of pressure on echocardiographic videodensity from sonicated albumin: an in vitro model.

Authors:  S Gottlieb; A Ernst; R S Meltzer
Journal:  J Ultrasound Med       Date:  1995-02       Impact factor: 2.153

6.  Effect of static pressure on the disappearance rate of specific echocardiographic contrast agents.

Authors:  C Vuille; M Nidorf; R L Morrissey; J B Newell; A E Weyman; M H Picard
Journal:  J Am Soc Echocardiogr       Date:  1994 Jul-Aug       Impact factor: 5.251

7.  Effects of left ventricular pressure on sonicated albumin microbubbles: evaluation using an isolated rabbit heart model.

Authors:  V Mor-Avi; S G Shroff; K A Robinson; A F Ng; B P Cholley; R H Marcus; R M Lang
Journal:  J Am Coll Cardiol       Date:  1994-12       Impact factor: 24.094

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.