Literature DB >> 7962030

Micromotion of femoral stems in total hip arthroplasty. A randomized study of cemented, hydroxyapatite-coated, and porous-coated stems with roentgen stereophotogrammetric analysis.

J Kärrholm1, H Malchau, F Snorrason, P Herberts.   

Abstract

The fixation of the femoral stem in a total hip arthroplasty was studied in sixty patients (sixty-four hips) with use of roentgen stereophotogrammetric analysis. The hips were randomly stratified on the basis of the age, sex, and weight of the patient; the roentgenographic quality of the bone; and the reason for the operation (primary or secondary osteoarthrosis). The hips were then randomly assigned to one of three types of fixation of the femoral component: insertion with cement, hydroxyapatite coating, or porous coating. Examinations with roentgen stereophotogrammetry were done as long as two years after the operation. Micromotion of the prostheses was evaluated in terms of subsidence or proximal migration and rotations and translations of the proximal-lateral (shoulder) and distal (tip) parts of the prostheses. The clinical results at the two-year follow-up evaluation did not differ significantly between the groups with regard to the Harris hip score or the pain score (p > 0.05 for both; Wilcoxon rank-sum test). There were small or no differences in rotations and micromotions of the shoulder and the tip of the prostheses. Increased subsidence of 0.1 to 0.2 millimeter was recorded for the cemented and the porous-coated prostheses (p = 0.002 and p = 0.02, respectively; Wilcoxon rank-sum test). Thus, proximal hydroxyapatite coating seems to enhance the early fixation of the stem. Conventional roentgenography revealed an increased number of radiodense lines surrounding the porous-coated prostheses. Distal hypertrophy of the femoral cortex was found mainly around the hydroxyapatite-coated prostheses. Proximal resorption of bone and heterotopic ossification occurred to approximately the same extent regardless of the type of fixation used.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 7962030     DOI: 10.2106/00004623-199411000-00013

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  20 in total

1.  The effects of hydroxyapatite coating and bone allograft on fixation of loaded experimental primary and revision implants.

Authors:  Kjeld Søballe; Olivier R G Mouzin; Louis A Kidder; Søren Overgaard; Joan E Bechtold
Journal:  Acta Orthop Scand       Date:  2003-06

2.  Femoral revision with an extensively hydroxyapatite-coated femoral component.

Authors:  Lawrence V Gulotta; Andreas Baldini; Kristin Foote; Stephen Lyman; Bryan J Nestor
Journal:  HSS J       Date:  2007-12-01

3.  Radiostereometric analysis: the hip.

Authors:  F Bottner; E Su; B Nestor; B Azzis; T P Sculco; M Bostrom
Journal:  HSS J       Date:  2005-09

4.  Accuracy of model-based RSA contour reduction in a typical clinical application.

Authors:  Christof Hurschler; Frank Seehaus; Judith Emmerich; Bart L Kaptein; Henning Windhagen
Journal:  Clin Orthop Relat Res       Date:  2008-05-29       Impact factor: 4.176

5.  Loosely implanted cementless stems may become rotationally stable after loading.

Authors:  Arun Kannan; John R Owen; Jennifer S Wayne; William A Jiranek
Journal:  Clin Orthop Relat Res       Date:  2014-03-25       Impact factor: 4.176

6.  Twenty-year results of the cementless Corail stem.

Authors:  Jean-Pierre Vidalain
Journal:  Int Orthop       Date:  2010-09-03       Impact factor: 3.075

7.  The effect on bone growth enhancement of implant coatings with hydroxyapatite and collagen deposited electrochemically and by plasma spray.

Authors:  Henrik Daugaard; Brian Elmengaard; Joan E Bechtold; Thomas Jensen; Kjeld Soballe
Journal:  J Biomed Mater Res A       Date:  2010-03-01       Impact factor: 4.396

Review 8.  Uncemented total hip arthroplasty in young patients with juvenile chronic arthritis.

Authors:  M N Kumar; M Swann
Journal:  Ann R Coll Surg Engl       Date:  1998-05       Impact factor: 1.891

9.  Nonmodular Tapered Fluted Titanium Stems Osseointegrate Reliably at Short Term in Revision THAs.

Authors:  Nemandra A Sandiford; Donald S Garbuz; Bassam A Masri; Clive P Duncan
Journal:  Clin Orthop Relat Res       Date:  2016-09-26       Impact factor: 4.176

10.  Clinical outcome and periprosthetic bone remodelling of an uncemented femoral component with taper design.

Authors:  Rainer Schmidt; Lutz Mueller; Tobias E Nowak; Rocco P Pitto
Journal:  Int Orthop       Date:  2003-04-12       Impact factor: 3.075

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.