Literature DB >> 7892478

Mammography with synchrotron radiation.

E Burattini1, E Cossu, C Di Maggio, M Gambaccini, P L Indovina, M Marziani, M Pocek, S Simeoni, G Simonetti.   

Abstract

PURPOSE: To determine the feasibility of using synchrotron radiation (SR) in diagnostic mammography.
MATERIALS AND METHODS: Monochromatic SR of x-ray beams of selected energies of 14-20 keV were used to obtain mammograms of surgically removed breast specimens that contained tumor nodules. For comparison, conventional mammograms of the same specimens were also obtained.
RESULTS: The mammograms obtained with SR had higher contrast and better resolution than did traditional mammograms and demonstrated excellent detail in all cases studied. The mean glandular doses at 17 and 18 keV were 1.56 and 0.83 mGy, respectively, which is compatible with the mean value of 1.41 mGy delivered with the conventional grid apparatus.
CONCLUSION: SR mammography appears to be a promising diagnostic imaging technique.

Entities:  

Mesh:

Year:  1995        PMID: 7892478     DOI: 10.1148/radiology.195.1.7892478

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  7 in total

1.  Near monochromatic X-rays for digital slot-scan mammography: initial findings.

Authors:  Felix Diekmann; S Diekmann; K Richter; U Bick; T Fischer; R Lawaczeck; W-R Press; K Schön; H-J Weinmann; V Arkadiev; A Bjeoumikhov; N Langhoff; J Rabe; P Roth; J Tilgner; R Wedell; M Krumrey; U Linke; G Ulm; B Hamm
Journal:  Eur Radiol       Date:  2004-06-30       Impact factor: 5.315

2.  Synchrotron radiation in radiology: radiology techniques based on synchrotron sources.

Authors:  Reto Meuli; Yeukuang Hwu; Jung Ho Je; Giorgio Margaritondo
Journal:  Eur Radiol       Date:  2004-07-31       Impact factor: 5.315

3.  Innovative radiographic system to improve the sharpness of radiographs: could a phase-shift effect contribute to improved image-quality for plain computed radiographs for general use?

Authors:  Junji Tanaka; Hiromi Oda; Toshihide Mimura; Chika Honda; Hiromu Oohara; Hiroaki Kawasaki; Atsushi Kondo; Yukihito Wada
Journal:  Jpn J Radiol       Date:  2010-01-30       Impact factor: 2.374

4.  Preliminary results of a study comparing conventional radiography with phase-contrast radiography for assessing root morphology of mandibular third molars.

Authors:  T Sato; N Nakamoto; T Abe; Y Fukushima; Y Tomaru; Y Sakata; M Nakazawa; A Nakamoto; H Kawasaki; Y Wada; H Ohara; R Araki; J Tanaka; T Yoda
Journal:  Dentomaxillofac Radiol       Date:  2011-02       Impact factor: 2.419

5.  Modeling, validation and application of a mathematical tissue-equivalent breast phantom for linear slot-scanning digital mammography.

Authors:  K Hussein; C L Vaughan; T S Douglas
Journal:  Phys Med Biol       Date:  2009-02-19       Impact factor: 3.609

6.  Signs analysis and clinical assessment: phase-contrast computed tomography of human breast tumours.

Authors:  Wushuai Jian; Mingshu Wu; Hongli Shi; Liting Wang; Lu Zhang; Shuqian Luo
Journal:  PLoS One       Date:  2015-04-06       Impact factor: 3.240

7.  Comparison of unmonochromatized synchrotron radiation and conventional X-rays in the imaging of mammographic phantom and human breast specimens: a preliminary result.

Authors:  Haijo Jung; Hee-Joung Kim; Eun-Kyung Kim; Jin-O Hong; Jung Ho Je; Yeukuang Hwu; Wen-Li Tsai; Giorgio Magaritondo; Hyung-Sik Yoo
Journal:  Yonsei Med J       Date:  2005-02-28       Impact factor: 2.759

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.