Literature DB >> 7862271

True proton density and T2-weighted turbo spin-echo sequences for routine MRI of the brain.

F Fellner1, R Schmitt, J Trenkler, C Fellner, T Helmberger, N Obletter, H Böhm-Jurkovic.   

Abstract

Our aim was to evaluate the diagnostic reliability of turbo spin-echo (TSE) sequences compared to a conventional dual-echo spin-echo (SE) sequence in routine brain MRI at 1.0 T. The following demands were made on TSE sequences: acquisition time-reduction of at least 50% and true proton density (PD) contrast (low-signal cerebrospinal fluid). A conventional spin-echo and two single-echo TSE sequences were used in 150 patients, a dual-echo TSE sequence in addition in 50 patients. Demonstration of most anatomical structures and disorders was equivalent with TSE and SE sequences. Advantages of TSE were reduced flow artefacts on T2-weighted images, better lesion contrast on PD-weighted TSE images (especially in the dual-echo sequence) and acquisition time reduction to about 5 min (single-echo TSE) and 3:35 min (dual-echo TSE). Disadvantages of TSE were: reduced contrast of iron-containing substances such as haemosiderin and of areas of calcification. By virtue of the shorter acquisition time and diagnostic reliability dual-echo TSE proved the best sequence. If it is used with only one acquisition--whereby image quality but not diagnostic reliability is slightly decreased--acquisition time can be further reduced to 1:48 min. Application of a susceptibility-sensitive gradient-echo sequence, such as FLASH, compensates for the disadvantages mentioned above.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 7862271     DOI: 10.1007/bf00600415

Source DB:  PubMed          Journal:  Neuroradiology        ISSN: 0028-3940            Impact factor:   2.804


  9 in total

1.  Practical choices of fast spin echo pulse sequence parameters: clinically useful proton density and T2-weighted contrasts.

Authors:  R D Tien; G J Felsberg; J MacFall
Journal:  Neuroradiology       Date:  1992       Impact factor: 2.804

2.  The loss of small objects in variable TE imaging: implications for FSE, RARE, and EPI.

Authors:  R T Constable; J C Gore
Journal:  Magn Reson Med       Date:  1992-11       Impact factor: 4.668

3.  Intracerebral lesion contrast with spin-echo and fast spin-echo pulse sequences.

Authors:  A M Norbash; G H Glover; D R Enzmann
Journal:  Radiology       Date:  1992-12       Impact factor: 11.105

4.  Magnetization transfer effects in multislice RARE sequences.

Authors:  P S Melki; R V Mulkern
Journal:  Magn Reson Med       Date:  1992-03       Impact factor: 4.668

5.  Fast spin-echo MR imaging of the brain and spine: current concepts.

Authors:  K M Jones; R V Mulkern; R B Schwartz; K Oshio; P D Barnes; F A Jolesz
Journal:  AJR Am J Roentgenol       Date:  1992-06       Impact factor: 3.959

6.  Rapid MR imaging of the pediatric brain using the fast spin-echo technique.

Authors:  S S Ahn; M T Mantello; K M Jones; R V Mulkern; P S Melki; N Higuchi; P D Barnes
Journal:  AJNR Am J Neuroradiol       Date:  1992 Jul-Aug       Impact factor: 3.825

7.  Brain hemorrhage: evaluation with fast spin-echo and conventional dual spin-echo images.

Authors:  K M Jones; R V Mulkern; M T Mantello; P S Melki; S S Ahn; P D Barnes; F A Jolesz
Journal:  Radiology       Date:  1992-01       Impact factor: 11.105

8.  RARE imaging: a fast imaging method for clinical MR.

Authors:  J Hennig; A Nauerth; H Friedburg
Journal:  Magn Reson Med       Date:  1986-12       Impact factor: 4.668

9.  Fast spin-echo imaging of intracranial neoplasms.

Authors:  H M Tice; K M Jones; R V Mulkern; R B Schwartz; P Kalina; S Ahn; P Barnes; F Jolesz
Journal:  J Comput Assist Tomogr       Date:  1993 May-Jun       Impact factor: 1.826

  9 in total
  3 in total

1.  Transition into driven equilibrium of the balanced steady-state free precession as an ultrafast multisection T2-weighted imaging of the brain.

Authors:  Y-C K Huang; T-Y Huang; H-C Chiu; T-S Kuo; C-J Hsueh; H-W Kao; C-W Wang; H-H Hsu; C-J Juan
Journal:  AJNR Am J Neuroradiol       Date:  2014-04-10       Impact factor: 3.825

2.  A T1-weighted rapid three-dimensional gradient-echo technique (MP-RAGE) in preoperative MRI of intracranial tumours.

Authors:  F Fellner; K Holl; P Held; C Fellner; R Schmitt; H Böhm-Jurkovic
Journal:  Neuroradiology       Date:  1996-04       Impact factor: 2.804

3.  High-resolution Structural Magnetic Resonance Imaging of the Human Subcortex In Vivo and Postmortem.

Authors:  Larissa McKetton; Joy Williams; Joseph D Viviano; Yeni H Yücel; Neeru Gupta; Keith A Schneider
Journal:  J Vis Exp       Date:  2015-12-30       Impact factor: 1.355

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.