Literature DB >> 1727309

Brain hemorrhage: evaluation with fast spin-echo and conventional dual spin-echo images.

K M Jones1, R V Mulkern, M T Mantello, P S Melki, S S Ahn, P D Barnes, F A Jolesz.   

Abstract

Signal intensity of blood products on proton-density- and T2-weighted images obtained with spin-echo (SE) and fast SE (FSE) sequences was evaluated in 15 patients with central nervous system hemorrhage to determine the extent of differences between the two techniques when signal loss from magnetic susceptibility effects in hemorrhagic lesions is considered. Within operator-defined regions of interest, signal intensity of hemorrhage, iron-containing nuclei, white matter, scalp fat, and noise was measured along the phase-encoding direction. Hemosiderin, deoxyhemoglobin, and iron-containing nuclei had slightly higher signal intensity on FSE images than on SE images, but the differences were not statistically significant. Signal intensity of methemoglobin was similar with both sequences, whereas that of scalp fat was higher on FSE images. Signal intensity measurements for most tissues studied were comparable, but the signal-to-noise ratios with FSE imaging were less than those with SE imaging. Although paramagnetic blood products may show slightly higher signal intensity with FSE imaging, contrast with the two sequences was comparable and lesion conspicuity was nearly identical.

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1727309     DOI: 10.1148/radiology.182.1.1727309

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  15 in total

Review 1.  Review of key concepts in magnetic resonance physics.

Authors:  Michael M Moore; Taylor Chung
Journal:  Pediatr Radiol       Date:  2017-04-13

2.  Improved delineation of ventricular shunt catheters using fast steady-state gradient recalled-echo sequences in a rapid brain MR imaging protocol in nonsedated pediatric patients.

Authors:  J H Miller; T Walkiewicz; R B Towbin; J G Curran
Journal:  AJNR Am J Neuroradiol       Date:  2009-11-26       Impact factor: 3.825

3.  Fast spin-echo MR imaging of the pediatric brain.

Authors:  V Engelbrecht; J Malms; T Kahn; S Grünewald; U Mödder
Journal:  Pediatr Radiol       Date:  1996

4.  Fast spin-echo MR imaging of the eye.

Authors:  N Hosten; A J Lemke; N Bornfeld; R Wassmuth; U Schweiger; K Terstegge; R Felix
Journal:  Eur Radiol       Date:  1996       Impact factor: 5.315

5.  Radiation risk due to shunted hydrocephalus and the role of MR imaging-safe programmable valves.

Authors:  S Krishnamurthy; B Schmidt; M D Tichenor
Journal:  AJNR Am J Neuroradiol       Date:  2012-11-01       Impact factor: 3.825

6.  Contrast on T2-weighted images of the lumbar spine using fast spin-echo and gated conventional spin-echo sequences.

Authors:  P M Chappell; G H Glover; D R Enzmann
Journal:  Neuroradiology       Date:  1995-04       Impact factor: 2.804

7.  True proton density and T2-weighted turbo spin-echo sequences for routine MRI of the brain.

Authors:  F Fellner; R Schmitt; J Trenkler; C Fellner; T Helmberger; N Obletter; H Böhm-Jurkovic
Journal:  Neuroradiology       Date:  1994-11       Impact factor: 2.804

8.  MR imaging of focal liver lesions: comparison between turbo spin-echo and conventional spin-echo pulse sequences.

Authors:  A Giovagnoni; E Paci; P Ercolani; B Kiefer; P Santino; A Piga
Journal:  MAGMA       Date:  1995 Sep-Dec       Impact factor: 2.310

9.  The value of MRI in angiogram-negative intracranial haemorrhage.

Authors:  S A Renowden; A J Molyneux; P Anslow; J V Byrne
Journal:  Neuroradiology       Date:  1994-08       Impact factor: 2.804

10.  A comparison between fast and conventional spin-echo in the detection of multiple sclerosis lesions.

Authors:  J W Thorpe; S F Halpin; D G MacManus; G J Barker; B E Kendall; D H Miller
Journal:  Neuroradiology       Date:  1994-07       Impact factor: 2.804

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.