Literature DB >> 8741186

A T1-weighted rapid three-dimensional gradient-echo technique (MP-RAGE) in preoperative MRI of intracranial tumours.

F Fellner1, K Holl, P Held, C Fellner, R Schmitt, H Böhm-Jurkovic.   

Abstract

Our purpose was to determine the value of a T1-weighted rapid three-dimensional gradient-echo technique in preoperative MRI of brain tumours. We examined 30 patients with intracranial tumours who underwent neurosurgery, using T1-weighted magnetisation-prepared rapid gradient-echo (MP-RAGE) and axial T1-weighted spin-echo (SE) sequences, both before and after contrast medium (Gd-DTPA). Signal and contrast behaviour of anatomical and pathological structures were assessed with regions-of-interest (ROI) and visual inspection. Imaging results were compared with operative results. In 5 cases tumours and anatomical structures were segmented in MP-RAGE data sets. The MP-RAGE sequence considerably improved delineation of grey and white matter and small anatomical structures (vessels, cranial nerves), and significantly reduced flow artefacts. Contrast behaviour of tumours was similar with both techniques. Correlation of imaging with the operative results confirmed the reliability of the MP-RAGE sequence. Segmentation of MP-RAGE data sets allows three-dimensional display, which enables one to document the relevant information on a few images in selected cases.

Entities:  

Mesh:

Year:  1996        PMID: 8741186     DOI: 10.1007/bf00596528

Source DB:  PubMed          Journal:  Neuroradiology        ISSN: 0028-3940            Impact factor:   2.804


  15 in total

1.  The loss of small objects in variable TE imaging: implications for FSE, RARE, and EPI.

Authors:  R T Constable; J C Gore
Journal:  Magn Reson Med       Date:  1992-11       Impact factor: 4.668

2.  MP RAGE: a three-dimensional, T1-weighted, gradient-echo sequence--initial experience in the brain.

Authors:  M Brant-Zawadzki; G D Gillan; W R Nitz
Journal:  Radiology       Date:  1992-03       Impact factor: 11.105

3.  FLASH imaging: rapid NMR imaging using low flip-angle pulses. 1986.

Authors:  A Haase; J Frahm; D Matthaei; W Hänicke; K-D Merboldt
Journal:  J Magn Reson       Date:  2011-12       Impact factor: 2.229

4.  Three-dimensional segmentation of MR images of the head using probability and connectivity.

Authors:  H E Cline; W E Lorensen; R Kikinis; F Jolesz
Journal:  J Comput Assist Tomogr       Date:  1990 Nov-Dec       Impact factor: 1.826

5.  Rapid three-dimensional T1-weighted MR imaging with the MP-RAGE sequence.

Authors:  J P Mugler; J R Brookeman
Journal:  J Magn Reson Imaging       Date:  1991 Sep-Oct       Impact factor: 4.813

6.  Inversion recovery snapshot FLASH MR imaging.

Authors:  A Haase; D Matthaei; R Bartkowski; E Dühmke; D Leibfritz
Journal:  J Comput Assist Tomogr       Date:  1989 Nov-Dec       Impact factor: 1.826

7.  Combined surface display and reformatting for the three-dimensional analysis of tomographic data.

Authors:  K H Hoehne; R L Delapaz; R Bernstein; R C Taylor
Journal:  Invest Radiol       Date:  1987-08       Impact factor: 6.016

8.  True proton density and T2-weighted turbo spin-echo sequences for routine MRI of the brain.

Authors:  F Fellner; R Schmitt; J Trenkler; C Fellner; T Helmberger; N Obletter; H Böhm-Jurkovic
Journal:  Neuroradiology       Date:  1994-11       Impact factor: 2.804

9.  Three-dimensional MR imaging and display of intracranial disease: improvements with the MP-RAGE sequence and gadolinium.

Authors:  M N Brant-Zawadzki; G D Gillan; D J Atkinson; N Edalatpour; M Jensen
Journal:  J Magn Reson Imaging       Date:  1993 Jul-Aug       Impact factor: 4.813

10.  True three-dimensional nuclear magnetic resonance zeugmatographic images of a human brain.

Authors:  D M Kramer; J S Schneider; A M Rudin; P C Lauterbur
Journal:  Neuroradiology       Date:  1981       Impact factor: 2.804

View more
  9 in total

Review 1.  Consensus recommendations for a standardized Brain Tumor Imaging Protocol in clinical trials.

Authors:  Benjamin M Ellingson; Martin Bendszus; Jerrold Boxerman; Daniel Barboriak; Bradley J Erickson; Marion Smits; Sarah J Nelson; Elizabeth Gerstner; Brian Alexander; Gregory Goldmacher; Wolfgang Wick; Michael Vogelbaum; Michael Weller; Evanthia Galanis; Jayashree Kalpathy-Cramer; Lalitha Shankar; Paula Jacobs; Whitney B Pope; Dewen Yang; Caroline Chung; Michael V Knopp; Soonme Cha; Martin J van den Bent; Susan Chang; W K Al Yung; Timothy F Cloughesy; Patrick Y Wen; Mark R Gilbert
Journal:  Neuro Oncol       Date:  2015-08-05       Impact factor: 12.300

2.  Retrograde cortical and deep venous drainage in patients with intracranial dural arteriovenous fistulas: comparison of MR imaging and angiographic findings.

Authors:  Mika Kitajima; Toshinori Hirai; Yukunori Korogi; Masayuki Yamura; Koichi Kawanaka; Ichiro Ikushima; Yoshiko Hayashida; Yasuyuki Yamashita; Junichi Kuratsu
Journal:  AJNR Am J Neuroradiol       Date:  2005 Jun-Jul       Impact factor: 3.825

3.  Improved Automatic Morphology-Based Classification of Parkinson's Disease and Progressive Supranuclear Palsy.

Authors:  Aron S Talai; Zahinoor Ismail; Jan Sedlacik; Kai Boelmans; Nils D Forkert
Journal:  Clin Neuroradiol       Date:  2018-09-14       Impact factor: 3.649

4.  Evaluation of the intracranial dural sinuses with a 3D contrast-enhanced MP-RAGE sequence: prospective comparison with 2D-TOF MR venography and digital subtraction angiography.

Authors:  L Liang; Y Korogi; T Sugahara; M Onomichi; Y Shigematsu; D Yang; M Kitajima; Y Hiai; M Takahashi
Journal:  AJNR Am J Neuroradiol       Date:  2001-03       Impact factor: 3.825

5.  3D magnetization-prepared imaging using a stack-of-rings trajectory.

Authors:  Holden H Wu; Dwight G Nishimura
Journal:  Magn Reson Med       Date:  2010-05       Impact factor: 4.668

6.  Flow ghost artifact in slice-encoding direction mimicking vestibular schwannoma in contrast-enhanced 3D spoiled gradient-echo sequence.

Authors:  Shinji Naganawa; Tokiko Koshikawa; Hiroshi Fukatsu; Takeo Ishigaki; Ikuo Aoki
Journal:  Eur Radiol       Date:  2003-11-05       Impact factor: 5.315

7.  T1 Signal-Intensity Increase in the Dentate Nucleus after Multiple Exposures to Gadodiamide: Intraindividual Comparison between 2 Commonly Used Sequences.

Authors:  J Ramalho; M Ramalho; M AlObaidy; R H Nunes; M Castillo; R C Semelka
Journal:  AJNR Am J Neuroradiol       Date:  2016-03-31       Impact factor: 3.825

8.  Three-dimensional T1-weighted gradient echo is a suitable alternative to two-dimensional T1-weighted spin echo for imaging the canine brain.

Authors:  Kathryn L Fleming; Thomas W Maddox; Christopher M R Warren-Smith
Journal:  Vet Radiol Ultrasound       Date:  2019-05-30       Impact factor: 1.363

9.  The effect of the MR pulse sequence on the regional corpus callosum morphometry.

Authors:  Fahad H Alhazmi; Osama M Abdulaal; Abdulaziz A Qurashi; Khalid M Aloufi; Vanessa Sluming
Journal:  Insights Imaging       Date:  2020-02-07
  9 in total