Effects of contrast equalization on energy imparted to the patient: a comparison of two dental generators and two types of intraoral film.

E Helmrot1, G A Carlsson, O Eckerdal.   

Abstract

Technical evolution in maxillofacial radiology has in the last decade provided faster films and the constant potential generator. The consequences of these innovations for radiographic contrast and energy imparted to the patient are analysed. On the basis of physical measurements a test model has been developed for correcting exposure parameters in order to maintain or restore image contrast. These measurements are expressed in and developed from basic radiological concepts and physical formulas presented in an earlier paper (Helmrot E. et al., Dentomaxillofac. Radiol. 1991; 20: 135-46). The test model can also be used to demonstrate the balance between contrast and energy imparted to the patient in the radiographic process. Changing to constant potential generators and faster film may each result in a degradation in contrast, which is possible to restore by a controlled adjustment of the kV-setting. Maintenance of constant image quality results in a slight reduction in the net gain in energy imparted, due to the generator and/or film shift. When, for example, a conventional single-pulse generator operated at 65kVp tube potential was replaced by a modern constant potential unit, the kV-setting had to be decreased by 5 to 8 kV to maintain the same radiographic contrast. This correction could be done without increasing energy imparted to the patient, taking into account the fact that the spectral characters of the photon energy are not identical. If, in addition, faster intraoral film with lower film contrast was introduced, together with the constant potential unit, the kV-setting had to be further decreased to maintain the radiographic contrast.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1994        PMID: 7835508     DOI: 10.1259/dmfr.23.2.7835508

Source DB:  PubMed          Journal:  Dentomaxillofac Radiol        ISSN: 0250-832X            Impact factor:   2.419


  5 in total

1.  A comprehensive in vitro study of image accuracy and quality for periodontal diagnosis. Part 1: the influence of X-ray generator on periodontal measurements using conventional and digital receptors.

Authors:  Bart Vandenberghe; Livia Corpas; Hilde Bosmans; Jie Yang; Reinhilde Jacobs
Journal:  Clin Oral Investig       Date:  2010-05-05       Impact factor: 3.573

Review 2.  Modern dental imaging: a review of the current technology and clinical applications in dental practice.

Authors:  Bart Vandenberghe; Reinhilde Jacobs; Hilde Bosmans
Journal:  Eur Radiol       Date:  2010-06-11       Impact factor: 5.315

3.  Development of a novel digital subtraction technique for detecting subtle changes in jawbone density.

Authors:  Frank Du Tré; Reinhilde Jacobs; Sean Styven; Daniel van Steenberghe
Journal:  Clin Oral Investig       Date:  2006-06-13       Impact factor: 3.573

4.  The way we were (and how we got here): fifty years of technology changes in dental and maxillofacial radiology.

Authors:  Roberto Molteni
Journal:  Dentomaxillofac Radiol       Date:  2020-06-11       Impact factor: 2.419

5.  The influence of tube potential on periodontal bone level measurements and subjective image quality using a digital photostimulable storage phosphor sensor.

Authors:  Bart Vandenberghe; Reinhilde Jacobs
Journal:  J Oral Maxillofac Res       Date:  2010-04-01
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.