Literature DB >> 16770624

Development of a novel digital subtraction technique for detecting subtle changes in jawbone density.

Frank Du Tré1, Reinhilde Jacobs, Sean Styven, Daniel van Steenberghe.   

Abstract

The objective of this paper is to develop a novel digital subtraction technique for serial intra-oral radiography, which would allow the detection of subtle variations in grey values. Digital images of the maxilla of a dried human skull and of a fresh pig mandible were acquired using intra-oral photostimulable phosphor plates (Digora FMX, Soredex, Helsinki) with an aluminium calibration stepwedge incorporated in the filmholder. Exposures were made with an X-ray tube for intra-oral radiography (Prostyle Intra, Planmeca, Helsinki). During pilot testing, parameter settings were adapted to reach an optimal contrast. Exposures were repeated within a 1-week interval to determine the test-retest reliability of the development. After in vitro and in vivo testing, the exposure technique and software development were used to evaluate its applicability in a pilot clinical case. Although parameter settings remained stable during the in vitro studies, the clinical exposures yielded non-linear digital images, thus, not readily suitable for data acquisition and comparison of the regions of interest. To allow further analysis, image processing was carried out using self-developed software for semi-automated linearisation and optimised contrast normalisation. This processing significantly increased the precise quantisation of jawbone density and the assessment of subtle bone density changes in arbitrarily selected regions of interest of in vivo exposures. The clinical applicability of the technique is demonstrated in a pilot case. It was demonstrated that minute densitometric deviations could be detected. The present technique and image processing may allow the quantification of jawbone density.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16770624     DOI: 10.1007/s00784-006-0055-2

Source DB:  PubMed          Journal:  Clin Oral Investig        ISSN: 1432-6981            Impact factor:   3.573


  43 in total

1.  Conventional and predicted perceptibility curves for contrast-enhanced direct digital intraoral radiographs.

Authors:  K Yoshiura; U Welander; X Q Shi; G Li; T Kawazu; M Tatsumi; K Okamura; W D McDavid; S Kanda
Journal:  Dentomaxillofac Radiol       Date:  2001-07       Impact factor: 2.419

2.  Precise image-receptor calibration and monitoring of beam quality with a step wedge.

Authors:  R A Couture; C F Hildebolt
Journal:  Dentomaxillofac Radiol       Date:  2002-01       Impact factor: 2.419

3.  Device for serial intraoral radiography with controlled projection angles.

Authors:  I Sewerin
Journal:  Tandlaegebladet       Date:  1990-10

4.  A precise receptor-positioning device for subtraction radiography, based on cross-arch stabilization.

Authors:  R A Couture; D A Dixon; C F Hildebolt
Journal:  Dentomaxillofac Radiol       Date:  2005-07       Impact factor: 2.419

5.  The performance of projective standardization for digital subtraction radiography.

Authors:  André Mol; Stanley M Dunn
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod       Date:  2003-09

6.  Quantitative subtraction with direct digital dental radiography.

Authors:  T Yoshioka; C Kobayashi; H Suda; T Sasaki
Journal:  Dentomaxillofac Radiol       Date:  1997-09       Impact factor: 2.419

7.  Evaluation of a dental subtraction radiography system.

Authors:  R P Ellwood; R M Davies; H V Worthington
Journal:  J Periodontal Res       Date:  1997-02       Impact factor: 4.419

8.  A contrast-correction method for digital subtraction radiography.

Authors:  M Ohki; T Okano; N Yamada
Journal:  J Periodontal Res       Date:  1988-07       Impact factor: 4.419

9.  Studies on the angular reproducibility of positioning patients adjacent to an x-ray tube. 2. A new electronically guided, force-sensitive sensor-based alignment system.

Authors:  E Hausmann; M E Kutlubay; D Odrobina; K M Allen; J Loza; L Ortman; D Wobschal
Journal:  J Periodontal Res       Date:  1995-07       Impact factor: 4.419

10.  The diagnostic value of subtraction radiography in the assessment of granular hydroxylapatite implants.

Authors:  W Engelke; S de Valk; U Ruttimann
Journal:  Oral Surg Oral Med Oral Pathol       Date:  1990-05
View more
  3 in total

1.  Bone density measurements in intra-oral radiographs.

Authors:  O Nackaerts; R Jacobs; K Horner; F Zhao; C Lindh; K Karayianni; P van der Stelt; S Pavitt; H Devlin
Journal:  Clin Oral Investig       Date:  2007-02-15       Impact factor: 3.573

2.  Effect of Contrast Inversion Enhancement on the Accuracy of Endodontic File Length Determination in Digital Radiography.

Authors:  Nastaran Farhadi; Ali Shokraneh; Mojdeh Mehdizadeh
Journal:  J Clin Diagn Res       Date:  2015-05-01

3.  Is there a relation between local bone quality as assessed on panoramic radiographs and alveolar bone level?

Authors:  Olivia Nackaerts; Frieda Gijbels; Anna-Maria Sanna; Reinhilde Jacobs
Journal:  Clin Oral Investig       Date:  2007-08-10       Impact factor: 3.573

  3 in total