Hand-scoring of MESAM 4 recordings is more accurate than automatic analysis in screening for obstructive sleep apnoea.

M Koziej1, J K Cieślicki, K Gorzelak, P Sliwiński, J Zieliński.   

Abstract

The MESAM 4 system, developed to monitor breathing sounds, heart rate, arterial oxygen saturation (Sao2) and body position, was proposed as a screening method for obstructive sleep apnoea (OSA). The aim of the study was to assess the accuracy of hand-scoring versus automatic-scoring in screening for obstructive sleep apnoea. The study population consisted of 56 patients, 51 males, and 5 females, mean age 47 +/- 10 yrs, suspected of having obstructive sleep apnoea. Full polysomnography and MESAM 4 recordings were performed simultaneously. The apnoea+hypopnoea index was hand-scored in polysomnography and in MESAM 4. The hand-scoring in MESAM 4 was based on analysis of breathing sounds, heart rate and Sao2 changes taken together. The automatic-scoring system of MESAM 4 calculated oxygen desaturation index, heart rate variation index and intermittent snoring index. The diagnosis of obstructive sleep apnoea (apnoea+hypopnoea index > or = 10) was established by polysomnography in 37 patients. Sensitivity and specificity of hand-scored MESAM 4 diagnosis were 100 and 63%, respectively. Sensitivity and specificity of MESAM 4 diagnosis with automatic-scoring were: from oxygen desaturation index 100 and 27%; from heart rate variation index 81 and 74%; and from intermittent snoring index 92 and 16%, respectively. We suggest that hand-scoring of MESAM 4 is more accurate than automatic-scoring in screening for obstructive sleep apnoea.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 7828683     DOI: 10.1183/09031936.94.07101771

Source DB:  PubMed          Journal:  Eur Respir J        ISSN: 0903-1936            Impact factor:   16.671


  8 in total

1.  Comparison of the automatic analysis versus the manual scoring from ApneaLink™ device for the diagnosis of obstructive sleep apnoea syndrome.

Authors:  Carlos Alberto Nigro; Eduardo Dibur; Silvia Aimaretti; Sergio González; Edgardo Rhodius
Journal:  Sleep Breath       Date:  2010-10-03       Impact factor: 2.816

2.  Computer-Assisted Automated Scoring of Polysomnograms Using the Somnolyzer System.

Authors:  Naresh M Punjabi; Naima Shifa; Georg Dorffner; Susheel Patil; Grace Pien; Rashmi N Aurora
Journal:  Sleep       Date:  2015-10-01       Impact factor: 5.849

3.  Misclassification of OSA severity with automated scoring of home sleep recordings.

Authors:  R Nisha Aurora; Rachel Swartz; Naresh M Punjabi
Journal:  Chest       Date:  2015-03       Impact factor: 9.410

4.  Validation of ApneaLink Ox™ for the diagnosis of obstructive sleep apnea.

Authors:  Carlos Alberto Nigro; Eduardo Dibur; Silvana Malnis; Sofia Grandval; Facundo Nogueira
Journal:  Sleep Breath       Date:  2012-03-25       Impact factor: 2.816

5.  Automatic breath-to-breath analysis of nocturnal polysomnographic recordings.

Authors:  P J van Houdt; P P W Ossenblok; M G van Erp; K E Schreuder; R J J Krijn; P A J M Boon; P J M Cluitmans
Journal:  Med Biol Eng Comput       Date:  2011-03-30       Impact factor: 2.602

6.  Obstructive sleep apnea in New Zealand adults: prevalence and risk factors among Māori and non-Māori.

Authors:  Kara M Mihaere; Ricci Harris; Philippa H Gander; Papaarangi M Reid; Gordon Purdie; Bridget Robson; Alister Neill
Journal:  Sleep       Date:  2009-07       Impact factor: 5.849

7.  Validation of the WristOx 3100 oximeter for the diagnosis of sleep apnea/hypopnea syndrome.

Authors:  Carlos Alberto Nigro; Silvia Aimaretti; Sergio Gonzalez; Edgardo Rhodius
Journal:  Sleep Breath       Date:  2008-10-02       Impact factor: 2.816

8.  First results of a prospective study validating the method of ambulatory polysomnography using the POLY-MESAM unit.

Authors:  T Verse; B Junge-Hülsing; B Kroker; W Pirsig; E Zimmermann
Journal:  Sleep Breath       Date:  1997-06       Impact factor: 2.816

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.