Literature DB >> 25411804

Misclassification of OSA severity with automated scoring of home sleep recordings.

R Nisha Aurora1, Rachel Swartz1, Naresh M Punjabi2.   

Abstract

BACKGROUND: The advent of home sleep testing has allowed for the development of an ambulatory care model for OSA that most health-care providers can easily deploy. Although automated algorithms that accompany home sleep monitors can identify and classify disordered breathing events, it is unclear whether manual scoring followed by expert review of home sleep recordings is of any value. Thus, this study examined the agreement between automated and manual scoring of home sleep recordings.
METHODS: Two type 3 monitors (ApneaLink Plus [ResMed] and Embletta [Embla Systems]) were examined in distinct study samples. Data from manual and automated scoring were available for 200 subjects. Two thresholds for oxygen desaturation (≥ 3% and ≥ 4%) were used to define disordered breathing events. Agreement between manual and automated scoring was examined using Pearson correlation coefficients and Bland-Altman analyses.
RESULTS: Automated scoring consistently underscored disordered breathing events compared with manual scoring for both sleep monitors irrespective of whether a ≥ 3% or ≥ 4% oxygen desaturation threshold was used to define the apnea-hypopnea index (AHI). For the ApneaLink Plus monitor, Bland-Altman analyses revealed an average AHI difference between manual and automated scoring of 6.1 (95% CI, 4.9-7.3) and 4.6 (95% CI, 3.5-5.6) events/h for the ≥ 3% and ≥ 4% oxygen desaturation thresholds, respectively. Similarly for the Embletta monitor, the average difference between manual and automated scoring was 5.3 (95% CI, 3.2-7.3) and 8.4 (95% CI, 7.2-9.6) events/h, respectively.
CONCLUSIONS: Although agreement between automated and manual scoring of home sleep recordings varies based on the device used, modest agreement was observed between the two approaches. However, manual review of home sleep test recordings can decrease the misclassification of OSA severity, particularly for those with mild disease. TRIAL REGISTRY: ClinicalTrials.gov; No.: NCT01503164; www.clinicaltrials.gov.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 25411804      PMCID: PMC4347534          DOI: 10.1378/chest.14-0929

Source DB:  PubMed          Journal:  Chest        ISSN: 0012-3692            Impact factor:   9.410


  28 in total

Review 1.  Computer-aided diagnosis and artificial intelligence in clinical imaging.

Authors:  Junji Shiraishi; Qiang Li; Daniel Appelbaum; Kunio Doi
Journal:  Semin Nucl Med       Date:  2011-11       Impact factor: 4.446

2.  Comparison of the automatic analysis versus the manual scoring from ApneaLink™ device for the diagnosis of obstructive sleep apnoea syndrome.

Authors:  Carlos Alberto Nigro; Eduardo Dibur; Silvia Aimaretti; Sergio González; Edgardo Rhodius
Journal:  Sleep Breath       Date:  2010-10-03       Impact factor: 2.816

3.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

Review 4.  Obstructive sleep apnoea syndrome: underestimated and undertreated.

Authors:  G J Gibson
Journal:  Br Med Bull       Date:  2005-03-29       Impact factor: 4.291

5.  Hand-scoring of MESAM 4 recordings is more accurate than automatic analysis in screening for obstructive sleep apnoea.

Authors:  M Koziej; J K Cieślicki; K Gorzelak; P Sliwiński; J Zieliński
Journal:  Eur Respir J       Date:  1994-10       Impact factor: 16.671

6.  Prolonged QT interval diagnosis suppression by a widely used computerized ECG analysis system.

Authors:  Anubhav Garg; Michael H Lehmann
Journal:  Circ Arrhythm Electrophysiol       Date:  2012-12-29

7.  Estimation of the clinically diagnosed proportion of sleep apnea syndrome in middle-aged men and women.

Authors:  T Young; L Evans; L Finn; M Palta
Journal:  Sleep       Date:  1997-09       Impact factor: 5.849

8.  An unattended device for sleep-related breathing disorders: validation study in suspected obstructive sleep apnoea syndrome.

Authors:  M Zucconi; L Ferini-Strambi; V Castronovo; A Oldani; S Smirne
Journal:  Eur Respir J       Date:  1996-06       Impact factor: 16.671

9.  Automated analysis of data is inferior to visual analysis of ambulatory sleep apnea monitoring.

Authors:  Ingo Fietze; Martin Glos; Jens Röttig; Christian Witt
Journal:  Respiration       Date:  2002       Impact factor: 3.580

10.  Clinical guidelines for the use of unattended portable monitors in the diagnosis of obstructive sleep apnea in adult patients. Portable Monitoring Task Force of the American Academy of Sleep Medicine.

Authors:  Nancy A Collop; W McDowell Anderson; Brian Boehlecke; David Claman; Rochelle Goldberg; Daniel J Gottlieb; David Hudgel; Michael Sateia; Richard Schwab
Journal:  J Clin Sleep Med       Date:  2007-12-15       Impact factor: 4.062

View more
  20 in total

1.  The Value of a Well-Trained Ear: Incidental Detection of Catathrenia on Home Sleep Apnea Tests in Patients With Low Probability for Obstructive Sleep Apnea.

Authors:  Louis Kazaglis
Journal:  J Clin Sleep Med       Date:  2018-12-15       Impact factor: 4.062

Review 2.  The why, when and how to test for obstructive sleep apnea in patients with atrial fibrillation.

Authors:  Lien Desteghe; Jeroen M L Hendriks; R Doug McEvoy; Ching Li Chai-Coetzer; Paul Dendale; Prashanthan Sanders; Hein Heidbuchel; Dominik Linz
Journal:  Clin Res Cardiol       Date:  2018-04-12       Impact factor: 5.460

3.  Underestimation of Sleep Apnea With Home Sleep Apnea Testing Compared to In-Laboratory Sleep Testing.

Authors:  Arveity R Setty
Journal:  J Clin Sleep Med       Date:  2017-04-15       Impact factor: 4.062

Review 4.  Methodological strategies in using home sleep apnea testing in research and practice.

Authors:  Jennifer N Miller; Paula Schulz; Bunny Pozehl; Douglas Fiedler; Alissa Fial; Ann M Berger
Journal:  Sleep Breath       Date:  2017-11-14       Impact factor: 2.816

5.  Validation of a new unattended sleep apnea monitor using two methods for the identification of hypopneas.

Authors:  Zbigniew L Topor; John E Remmers; Joshua Grosse; Erin V Mosca; Seyed A Zareian Jahromi; Yingyu Zhu; Sabina Bruehlmann
Journal:  J Clin Sleep Med       Date:  2020-02-06       Impact factor: 4.062

6.  Potential Underestimation of Sleep Apnea Severity by At-Home Kits: Rescoring In-Laboratory Polysomnography Without Sleep Staging.

Authors:  Matt T Bianchi; Balaji Goparaju
Journal:  J Clin Sleep Med       Date:  2017-04-15       Impact factor: 4.062

7.  Sleepiness and sleep-disordered breathing during pregnancy.

Authors:  Maria Sarberg; Marie Bladh; Ann Josefsson; Eva Svanborg
Journal:  Sleep Breath       Date:  2016-04-16       Impact factor: 2.816

8.  Agreement in the Scoring of Respiratory Events Among International Sleep Centers for Home Sleep Testing.

Authors:  Ulysses J Magalang; Erna S Arnardottir; Ning-Hung Chen; Peter A Cistulli; Thorarinn Gíslason; Diane Lim; Thomas Penzel; Richard Schwab; Sergio Tufik; Allan I Pack
Journal:  J Clin Sleep Med       Date:  2016-01       Impact factor: 4.062

9.  Effect of Varying Definitions of Hypopnea on the Diagnosis and Clinical Outcomes of Sleep-Disordered Breathing: A Systematic Review and Meta-Analysis.

Authors:  Meghna P Mansukhani; Bhanu Prakash Kolla; Zhen Wang; Timothy I Morgenthaler
Journal:  J Clin Sleep Med       Date:  2019-05-15       Impact factor: 4.062

10.  In-Home Sleep Apnea Severity Classification using Contact-free Load Cells and an AdaBoosted Decision Tree Algorithm.

Authors:  Clara Mosquera-Lopez; Joseph Leitschuh; John Condon; Chad C Hagen; Cody Hanks; Peter G Jacobs
Journal:  Annu Int Conf IEEE Eng Med Biol Soc       Date:  2018-07
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.