Literature DB >> 22447171

Validation of ApneaLink Ox™ for the diagnosis of obstructive sleep apnea.

Carlos Alberto Nigro1, Eduardo Dibur, Silvana Malnis, Sofia Grandval, Facundo Nogueira.   

Abstract

OBJECTIVE: The aim of the study was to validate the automatic and manual analysis of ApneaLink Ox™ (ALOX) in patients with suspected obstructive sleep apnea (OSA).
METHODS: All patients with suspected OSA had a polysomnography (PSG) and an ALOX performed in the sleep laboratory. For automatic analysis, hypopnea was defined as a decrease in airflow ≥30 % of baseline for at least 10 s plus oxygen desaturation ≥3 or 4 %. While for the manual analysis, hypopnoea was considered when a reduction of airflow ≥30 % of ≥10 s plus oxygen desaturation ≥3 % or increase in cardiac rate ≥5 beats/min were identified or, when only a reduction of airflow ≥50 % was observed. OSA was defined as a respiratory disturbance index (RDI) ≥5. The apnea/hypopnea automatic index (AHI3-a, AHI4-a) and manual index were estimated. Receiver operating characteristics (ROC) analysis and the agreement between ALOX and PSG were performed.
RESULTS: Fifty-five patients were included (38 men; mean age, 48.2; median, RDI 15.1; median BMI, 30 Kg/m(2)). The automatic analysis of ALOX under-estimated the RDI from PSG, mainly for the criterion of oxygen desaturation ≥4 % (AHI3-a-RDI, -3.6 ± 10.1; AHI4-a-RDI, -6.5 ± 10.9, p < 0.05). The autoscoring from ALOX device showed a better performance when it was set up to identify hypopneas with an oxygen desaturation criterion of ≥3 % than when it was configured with an oxygen desaturation criterion of ≥4 % (area under the receiver operator curves, 0.87 vs. 0.84). Also, the manual analysis was found to be better than the autoscoring set up with an oxygen desaturation of ≥3 % (0.923 vs. 0.87). The manual analysis showed a good interobserver agreement for the classification of patients with or without OSA (k = 0.81).
CONCLUSION: The AHI obtained automatically from the ApneaLink Ox™ using oxygen desaturation ≥3 % as a criterion of hypopnea had a good performance to diagnose OSA. The manual scoring from ApneaLink Ox™ was better than the automatic scoring to discriminate patients with OSA.

Entities:  

Mesh:

Year:  2012        PMID: 22447171     DOI: 10.1007/s11325-012-0684-4

Source DB:  PubMed          Journal:  Sleep Breath        ISSN: 1520-9512            Impact factor:   2.816


  30 in total

1.  Relation of sleep-disordered breathing to cardiovascular disease risk factors: the Sleep Heart Health Study.

Authors:  A B Newman; F J Nieto; U Guidry; B K Lind; S Redline; T G Pickering; S F Quan
Journal:  Am J Epidemiol       Date:  2001-07-01       Impact factor: 4.897

2.  [Prevalence of obstructive sleep apnea-hypopnea syndrome in Chinese adults aged over 30 yr in Shanghai].

Authors:  Shao-guang Huang; Qing-yun Li
Journal:  Zhonghua Jie He He Hu Xi Za Zhi       Date:  2003-05

3.  Comparison of the automatic analysis versus the manual scoring from ApneaLink™ device for the diagnosis of obstructive sleep apnoea syndrome.

Authors:  Carlos Alberto Nigro; Eduardo Dibur; Silvia Aimaretti; Sergio González; Edgardo Rhodius
Journal:  Sleep Breath       Date:  2010-10-03       Impact factor: 2.816

4.  A simplified model of screening questionnaire and home monitoring for obstructive sleep apnoea in primary care.

Authors:  Ching Li Chai-Coetzer; Nick A Antic; L Sharn Rowland; Peter G Catcheside; Adrian Esterman; Richard L Reed; Helena Williams; Sandra Dunn; R Doug McEvoy
Journal:  Thorax       Date:  2011-01-20       Impact factor: 9.139

5.  Hand-scoring of MESAM 4 recordings is more accurate than automatic analysis in screening for obstructive sleep apnoea.

Authors:  M Koziej; J K Cieślicki; K Gorzelak; P Sliwiński; J Zieliński
Journal:  Eur Respir J       Date:  1994-10       Impact factor: 16.671

Review 6.  Portable recording in the assessment of obstructive sleep apnea. ASDA standards of practice.

Authors:  R Ferber; R Millman; M Coppola; J Fleetham; C F Murray; C Iber; W V McCall; G Nino-Murcia; M Pressman; M Sanders
Journal:  Sleep       Date:  1994-06       Impact factor: 5.849

7.  Non-Invasive detection of respiratory effort-related arousals (REras) by a nasal cannula/pressure transducer system.

Authors:  I Ayappa; R G Norman; A C Krieger; A Rosen; R L O'malley; D M Rapoport
Journal:  Sleep       Date:  2000-09-15       Impact factor: 5.849

8.  Evaluation of a single-channel portable monitor for the diagnosis of obstructive sleep apnea.

Authors:  Burcu Oktay; Thomas B Rice; Charles W Atwood; Michael Passero; Neeraj Gupta; Rachel Givelber; Oliver J Drumheller; Patricia Houck; Nancy Gordon; Patrick J Strollo
Journal:  J Clin Sleep Med       Date:  2011-08-15       Impact factor: 4.062

9.  Diagnostic performance of single airflow channel recording (ApneaLink) in home diagnosis of sleep apnea.

Authors:  Regine Ragette; Yi Wang; Gerhard Weinreich; Helmut Teschler
Journal:  Sleep Breath       Date:  2009-08-28       Impact factor: 2.816

10.  Validation of the ApneaLink for the screening of sleep apnea: a novel and simple single-channel recording device.

Authors:  Milton K Erman; Deirdre Stewart; Daniel Einhorn; Nancy Gordon; Eileen Casal
Journal:  J Clin Sleep Med       Date:  2007-06-15       Impact factor: 4.062

View more
  21 in total

1.  Diagnostic accuracy of level IV portable sleep monitors versus polysomnography for obstructive sleep apnea: a systematic review and meta-analysis.

Authors:  Lusine Abrahamyan; Yeva Sahakyan; Suzanne Chung; Petros Pechlivanoglou; Joanna Bielecki; Steven M Carcone; Valeria E Rac; Michael Fitzpatrick; Murray Krahn
Journal:  Sleep Breath       Date:  2018-01-09       Impact factor: 2.816

2.  Sleep scoring: man vs. machine?

Authors:  Christian Berthomier; Marie Brandewinder
Journal:  Sleep Breath       Date:  2012-05-06       Impact factor: 2.816

3.  Validation of ApneaLink™ Plus for the diagnosis of sleep apnea.

Authors:  Jae Hoon Cho; Hyun Jun Kim
Journal:  Sleep Breath       Date:  2017-07-01       Impact factor: 2.816

4.  Obstructive sleep apnea and stroke: hand in hand?

Authors:  Owen D Lyons; Clodagh M Ryan
Journal:  J Thorac Dis       Date:  2018-04       Impact factor: 2.895

5.  A Comprehensive Evaluation of a Two-Channel Portable Monitor to "Rule in" Obstructive Sleep Apnea.

Authors:  Kim L Ward; Nigel McArdle; Alan James; Alexandra P Bremner; Laila Simpson; Matthew N Cooper; Lyle J Palmer; Annette C Fedson; Sutapa Mukherjee; David R Hillman
Journal:  J Clin Sleep Med       Date:  2015-04-15       Impact factor: 4.062

6.  Central sleep apnea in multiple sclerosis: a pilot study.

Authors:  Michael Lin; Arun V Krishnan; Danny J Eckert
Journal:  Sleep Breath       Date:  2016-12-14       Impact factor: 2.816

7.  Cognitive profiles in obstructive sleep apnea: a cluster analysis in sleep clinic and community samples.

Authors:  Michelle Olaithe; Maria Pushpanathan; David Hillman; Peter R Eastwood; Michael Hunter; Timothy Skinner; Alan James; Keith A Wesnes; Romola S Bucks
Journal:  J Clin Sleep Med       Date:  2020-09-15       Impact factor: 4.062

8.  Do apneas and hypopneas best reflect risk for poor outcomes after stroke?

Authors:  Devin L Brown; Fatema Shafie-Khorassani; Sehee Kim; Ronald D Chervin; Erin Case; Azadeh Yadollahi; Lynda D Lisabeth
Journal:  Sleep Med       Date:  2019-05-27       Impact factor: 3.492

9.  Is portable monitoring for diagnosing obstructive sleep apnea syndrome suitable in elderly population?

Authors:  Jéssica Fabia Polese; Rogerio Santos-Silva; Paula Martins de Oliveira Ferrari; Denis Eduardo Sartori; Sergio Tufik; Lia Bittencourt
Journal:  Sleep Breath       Date:  2012-07-04       Impact factor: 2.816

10.  Validation of the MediByte Portable Monitor for the Diagnosis of Sleep Apnea in Pediatric Patients.

Authors:  Ahmed I Masoud; Pallavi P Patwari; Pranshu A Adavadkar; Henry Arantes; Chang Park; David W Carley
Journal:  J Clin Sleep Med       Date:  2019-05-15       Impact factor: 4.062

View more