Literature DB >> 7803355

Optic disc measurement with the Zeiss four mirror contact lens.

A F Spencer1, S A Vernon.   

Abstract

A knowledge of the optic disc size may be of value when assessing the glaucoma suspect. The vertical diameter of the optic disc was measured using a Zeiss four mirror gonioscope and a 900 Haag-Streit slit-lamp in one eye of 39 patients, 32 with refractive errors within 3 dioptres of emmetropia. The disc was measured by projecting a slit beam of known height onto the image of the disc. A magnification factor for the contact lens was calculated from first principles and disc height recalculated. These measurements were compared with those obtained by photographic methods using the corrections suggested by Bengtsson and Krakau. In the analysis on the 32 eyes within 3 dioptres of emmetropia the best correlation with clinical measurements was obtained with correction 3 using spectacle refraction and keratometry (r = 0.8614). The contact lens measurement was within plus or minus 0.1 mm of the photographic measurement in 67% of cases and plus or minus 0.2 mm in all cases. This simple method is advocated for the routine assessment of optic disc size.

Entities:  

Mesh:

Year:  1994        PMID: 7803355      PMCID: PMC504934          DOI: 10.1136/bjo.78.10.775

Source DB:  PubMed          Journal:  Br J Ophthalmol        ISSN: 0007-1161            Impact factor:   4.638


  28 in total

1.  Correction of optic disc measurements on fundus photographs.

Authors:  B Bengtsson; C E Krakau
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1992       Impact factor: 3.117

2.  Measuring fundus landmarks.

Authors:  A M Mansour
Journal:  Invest Ophthalmol Vis Sci       Date:  1990-01       Impact factor: 4.799

3.  Absolute ocular fundus dimensions measured by multiple-beam interference fringes.

Authors:  P Baumbach; B Rassow; W Wesemann
Journal:  Invest Ophthalmol Vis Sci       Date:  1989-11       Impact factor: 4.799

4.  Reproducibility of optic disc measurements with computerized analysis of stereoscopic video images.

Authors:  J Caprioli; U Klingbeil; M Sears; B Pope
Journal:  Arch Ophthalmol       Date:  1986-07

5.  The correlation between cup-disk ratio, neuroretinal rim area, and optic disk area measured by the video-ophthalmograph (Rodenstock analyzer) and clinical measurement.

Authors:  F S Mikelberg; G R Douglas; M Schulzer; P J Airaksinen; K Wijsman; D Mawson
Journal:  Am J Ophthalmol       Date:  1986-01-15       Impact factor: 5.258

6.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

7.  Possible errors in the measurement of retinal lesions.

Authors:  J V Arnold; J W Gates; K M Taylor
Journal:  Invest Ophthalmol Vis Sci       Date:  1993-07       Impact factor: 4.799

8.  [Determination of the real size of an object on the fundus of the living eye].

Authors:  H Littmann
Journal:  Klin Monbl Augenheilkd       Date:  1982-04       Impact factor: 0.700

9.  Measurement of optic disc and neuroretinal rim areas in normal and glaucomatous eyes. A new clinical method.

Authors:  D M Montgomery
Journal:  Ophthalmology       Date:  1991-01       Impact factor: 12.079

10.  Optic nerve hypoplasia: papillary diameter and clinical correlation.

Authors:  L Beuchat; A B Safran
Journal:  J Clin Neuroophthalmol       Date:  1985-12
View more
  6 in total

Review 1.  The definition and classification of glaucoma in prevalence surveys.

Authors:  Paul J Foster; Ralf Buhrmann; Harry A Quigley; Gordon J Johnson
Journal:  Br J Ophthalmol       Date:  2002-02       Impact factor: 4.638

2.  Neuroretinal rim width ratios in morphological glaucoma diagnosis.

Authors:  J B Jonas; W M Budde; P Lang
Journal:  Br J Ophthalmol       Date:  1998-12       Impact factor: 4.638

3.  Optic disc measurement: a comparison of indirect ophthalmoscopic methods.

Authors:  A F Spencer; S A Vernon
Journal:  Br J Ophthalmol       Date:  1995-10       Impact factor: 4.638

4.  Determination of the neuroretinal rim area using the horizontal and vertical disc and cup diameters.

Authors:  J B Jonas; D M Montgomery
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1995-11       Impact factor: 3.117

5.  Vertical cup/disc ratio in relation to optic disc size: its value in the assessment of the glaucoma suspect.

Authors:  D F Garway-Heath; S T Ruben; A Viswanathan; R A Hitchings
Journal:  Br J Ophthalmol       Date:  1998-10       Impact factor: 4.638

6.  An innovative and simple method, clinically comparable to high-definition optical coherence tomography in quantifying posterior segment lesions in the retina.

Authors:  Shaji P Koshy; Leena Mariyam Varghese; Satish Thomas; Pramod Thomas
Journal:  Indian J Ophthalmol       Date:  2020-05       Impact factor: 1.848

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.