Literature DB >> 2298541

Measuring fundus landmarks.

A M Mansour1.   

Abstract

Three methods of determining the actual size of objects on the living fundus were utilized to measure the horizontal disc diameter (H) in 68 volunteers. H1 was calculated from fundus photographs based on the refractive power of the eye and according to the formula of Bengtsson and Krakau. H2 was derived from Littmann's trigonometric curves based on the anterior corneal curvature and the refractive power of the eye. H3 was derived from Littmann's trigonometric curves based on the axial length and the refractive power of the eye. H1 underestimated H2 by a mean of 0.91% (S.D. 2.19%) in 68 eyes. H3 underestimated H2 by a mean of 3.6% (S.D. 4.0%). We concluded that H1 was an acceptable approximation of H2 in a clinical setting and retrospective studies.

Entities:  

Mesh:

Year:  1990        PMID: 2298541

Source DB:  PubMed          Journal:  Invest Ophthalmol Vis Sci        ISSN: 0146-0404            Impact factor:   4.799


  10 in total

1.  Analysis of retinal fundus images for grading of diabetic retinopathy severity.

Authors:  M H Ahmad Fadzil; Lila Iznita Izhar; Hermawan Nugroho; Hanung Adi Nugroho
Journal:  Med Biol Eng Comput       Date:  2011-01-27       Impact factor: 2.602

2.  Correction of optic disc measurements on fundus photographs.

Authors:  B Bengtsson; C E Krakau
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1992       Impact factor: 3.117

3.  Optic disc size in a population based study in northern China: the Beijing Eye Study.

Authors:  Y Wang; L Xu; L Zhang; H Yang; Y Ma; J B Jonas
Journal:  Br J Ophthalmol       Date:  2006-03       Impact factor: 4.638

4.  Visual evoked potentials in macular hole.

Authors:  M Kato; T Nakagami; I Watanabe
Journal:  Doc Ophthalmol       Date:  1991       Impact factor: 2.379

5.  Optic disc measurement: a comparison of indirect ophthalmoscopic methods.

Authors:  A F Spencer; S A Vernon
Journal:  Br J Ophthalmol       Date:  1995-10       Impact factor: 4.638

6.  Optic disc measurement with the Zeiss four mirror contact lens.

Authors:  A F Spencer; S A Vernon
Journal:  Br J Ophthalmol       Date:  1994-10       Impact factor: 4.638

7.  Analysis of foveal avascular zone for grading of diabetic retinopathy severity based on curvelet transform.

Authors:  Shirin Hajeb Mohammad Alipour; Hossein Rabbani; Mohammadreza Akhlaghi; Alireza Mehri Dehnavi; Shaghayegh Haghjooy Javanmard
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2012-07-04       Impact factor: 3.117

8.  Determination of foveal location using scanning laser polarimetry.

Authors:  Dean A VanNasdale; Ann E Elsner; Anke Weber; Masahiro Miura; Bryan P Haggerty
Journal:  J Vis       Date:  2009-03-25       Impact factor: 2.240

9.  Analysis of optical coherence angiography in cystoid macular oedema associated with gyrate atrophy.

Authors:  Ahmad M Mansour; Ayman G Elnahry; Koushik Tripathy; Robert E Foster; Carl-Jo Mehanna; Raval Vishal; Cemal Çavdarlı; Alessandro Arrigo; Maurizio Battaglia Parodi
Journal:  Eye (Lond)       Date:  2020-09-01       Impact factor: 4.456

10.  Measurement of optic disc size: equivalence of methods to correct for ocular magnification.

Authors:  D F Garway-Heath; A R Rudnicka; T Lowe; P J Foster; F W Fitzke; R A Hitchings
Journal:  Br J Ophthalmol       Date:  1998-06       Impact factor: 5.908

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.