Literature DB >> 7797773

Noninvasive identification of acute myocardial ischemia and reperfusion with contrast ultrasound using intravenous perfluoropropane-exposed sonicated dextrose albumin.

T R Porter1, F Xie, A Kricsfeld, K Kilzer.   

Abstract

OBJECTIVES: The purpose of this study was to determine whether intravenous dextrose albumin sonicated with a commonly used gas of low blood solubility and diffusivity (perfluoropropane) could identify acute myocardial ischemia and reperfusion.
BACKGROUND: Recently, it has been demonstrated that dextrose albumin sonicated with gases that have low blood solubility and diffusivity results in microbubbles capable of consistently producing myocardial ultrasound contrast after intravenous injection. It remains to be determined, however, whether this contrast agent can visually detect the myocardial blood flow abnormalities seen with acute ischemia or stunned myocardium after reperfusion.
METHODS: We gave intravenous injections (0.06 ml/kg body weight) of perfluoropropane-exposed sonicated dextrose albumin to 10 open chest dogs. The measured degree of myocardial contrast (0+ to 2+) and background-subtracted peak anterior myocardial videointensity produced from each injection were measured at three stages: 1) under baseline conditions, 2) during acute ischemia produced by a proximal left anterior descending coronary artery ligation lasting 10 to 120 min, and 3) after reflow was established. Coronary blood flow was monitored during all injections by using an ultrasound flow probe placed around the left anterior descending artery.
RESULTS: Coronary blood flow ranged from 0 to 137 ml/min, and peak myocardial videointensity after intravenous administration of perfluoropropane-exposed sonicated dextrose albumin ranged from 0 to 70 gray scale U. There was consistent visual myocardial opacification in all dogs during baseline conditions and a visually evident decrease in myocardial contrast in the left anterior descending artery distribution after ligation. A relative increase in contrast in this same distribution after intravenous contrast agent administration occurred in 7 of the 10 dogs during reflow. Quantitatively, there was an excellent correlation in individual dogs between peak myocardial videointensity and coronary flow at all stages (mean correlation coefficient 0.95 +/- 0.04, range 0.87 to 0.99).
CONCLUSIONS: Perfluoropropane-exposed sonicated dextrose albumin is an ultrasound contrast agent that can visually identify myocardial perfusion abnormalities from a peripheral venous injection.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7797773     DOI: 10.1016/0735-1097(95)00132-j

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  15 in total

Review 1.  Section 8--clinical relevance. American Institute of Ultrasound in Medicine.

Authors: 
Journal:  J Ultrasound Med       Date:  2000-02       Impact factor: 2.153

Review 2.  Section 6--mechanical bioeffects in the presence of gas-carrier ultrasound contrast agents. American Institute of Ultrasound in Medicine.

Authors: 
Journal:  J Ultrasound Med       Date:  2000-02       Impact factor: 2.153

Review 3.  Section 7--discussion of the mechanical index and other exposure parameters. American Institute of Ultrasound in Medicine.

Authors: 
Journal:  J Ultrasound Med       Date:  2000-02       Impact factor: 2.153

Review 4.  Section 4--bioeffects in tissues with gas bodies. American Institute of Ultrasound in Medicine.

Authors: 
Journal:  J Ultrasound Med       Date:  2000-02       Impact factor: 2.153

Review 5.  Added value of contrast echocardiography in assessing myocardial viability.

Authors:  A Nagy; F L Dini; D Rovai
Journal:  Heart       Date:  1999-11       Impact factor: 5.994

6.  [Noninvasive determination of coronary flow reserve with signal enhanced high resolution transthoracic Doppler color echocardiography].

Authors:  H Lambertz; J Bönhof; J Brechtken; T Stein; H P Tries; H Lethen
Journal:  Herz       Date:  1998-12       Impact factor: 1.443

Review 7.  Contrast echocardiography 1996. A review.

Authors:  H R Villarraga; D A Foley; S L Mulvagh
Journal:  Tex Heart Inst J       Date:  1996

8.  Resting qualitative and quantitative myocardial contrast echocardiography to predict cardiac events in patients with acute myocardial infarction and percutaneous revascularization.

Authors:  Sahar S Abdelmoneim; Matthew W Martinez; Sunil V Mankad; Mathieu Bernier; Abhijeet Dhoble; Patricia A Pellikka; Krishnaswamy Chandrasekaran; Jae K Oh; Sharon L Mulvagh
Journal:  Heart Vessels       Date:  2014-01-10       Impact factor: 2.037

9.  Effect of power Doppler and digital subtraction techniques on the comparison of myocardial contrast echocardiography with SPECT.

Authors:  B Haluska; C Case; L Short; J Anderson; T H Marwick
Journal:  Heart       Date:  2001-05       Impact factor: 5.994

10.  Sonothrombolysis: an emerging modality for the treatment of acute ischemic and hemorrhagic stroke.

Authors:  Azita Soltani; Wayne M Clark; Douglas R Hansmann
Journal:  Transl Stroke Res       Date:  2011-04-15       Impact factor: 6.829

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.