OBJECTIVE: To compare the accuracy and feasibility of harmonic power Doppler and digitally subtracted colour coded grey scale imaging for the assessment of perfusion defect severity by single photon emission computed tomography (SPECT) in an unselected group of patients.
DESIGN: Cohort study.
SETTING: Regional cardiothoracic unit. PATIENTS: 49 patients (mean (SD) age 61 (11) years; 27 women, 22 men) with known or suspected coronary artery disease were studied with simultaneous myocardial contrast echo (MCE) and SPECT after standard dipyridamole stress. MAIN OUTCOME MEASURES: Regional myocardial perfusion by SPECT, performed with (99m)Tc tetrafosmin, scored qualitatively and also quantitated as per cent maximum activity.
RESULTS: Normal perfusion was identified by SPECT in 225 of 270 segments (83%). Contrast echo images were interpretable in 92% of patients. The proportion of normal MCE by grey scale, subtracted, and power Doppler techniques were respectively 76%, 74%, and 88% (p < 0.05) at > 80% of maximum counts, compared with 65%, 69%, and 61% at < 60% of maximum counts. For each technique, specificity was lowest in the lateral wall, although power Doppler was the least affected. Grey scale and subtraction techniques were least accurate in the septal wall, but power Doppler showed particular problems in the apex. On a per patient analysis, the sensitivity was 67%, 75%, and 83% for detection of coronary artery disease using grey scale, colour coded, and power Doppler, respectively, with a significant difference between power Doppler and grey scale only (p < 0.05). Specificity was also the highest for power Doppler, at 55%, but not significantly different from subtracted colour coded images.
CONCLUSIONS: Myocardial contrast echo using harmonic power Doppler has greater accuracy than with grey scale imaging and digital subtraction. However, power Doppler appears to be less sensitive for mild perfusion defects.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11303008      PMCID: PMC1729711          DOI: 10.1136/heart.85.5.549

Source DB:  PubMed          Journal:  Heart        ISSN: 1355-6037            Impact factor:   5.994


  20 in total

1.  Effect of color coding and subtraction on the accuracy of contrast echocardiography.

Authors:  A Pasquet; N Greenberg; R Brunken; J D Thomas; T H Marwick
Journal:  Int J Cardiol       Date:  1999-08-31       Impact factor: 4.164

2.  Prognostic value of thallium-201 single-photon emission computed tomography for patients with multivessel coronary artery disease after revascularization (the Emory Angioplasty versus Surgery Trial [EAST]).

Authors:  N P Alazraki; E G Krawczynska; A S Kosinski; E G DePuey; J A Ziffer; A T Taylor; R I Pettigrew; J P Vansant; L J Shaw; W S Weintraub; S B King
Journal:  Am J Cardiol       Date:  1999-12-15       Impact factor: 2.778

3.  Harmonic Power Doppler Contrast Echocardiography: Preliminary Experimental Results.

Authors:  Dipak I. Agrawal; Sanjay Malhotra; Navin C. Nanda; Claudia Carvalho Truffa; Gopal Agrawal; Abhash C. Thakur; Farrukh Jamil; Gregg W. Taylor; Harald Becher
Journal:  Echocardiography       Date:  1997-11       Impact factor: 1.724

4.  Technetium-99m sestamibi and tetrofosmin myocardial single-photon emission tomography: can we use the same reference data base?

Authors:  A Widding; B Hesse; N Gadsboll
Journal:  Eur J Nucl Med       Date:  1997-01

5.  Myocardial contrast echocardiography: too much, too soon?

Authors:  A N DeMaria; B Cotter; K Ohmori
Journal:  J Am Coll Cardiol       Date:  1998-11       Impact factor: 24.094

6.  Digital subtraction contrast echocardiography: a new method for the evaluation of regional myocardial perfusion.

Authors:  M J Monaghan; P J Quigley; J M Metcalfe; S D Thomas; D E Jewitt
Journal:  Br Heart J       Date:  1988-01

7.  Incremental prognostic value of myocardial perfusion single photon emission computed tomography for the prediction of cardiac death: differential stratification for risk of cardiac death and myocardial infarction.

Authors:  R Hachamovitch; D S Berman; L J Shaw; H Kiat; I Cohen; J A Cabico; J Friedman; G A Diamond
Journal:  Circulation       Date:  1998-02-17       Impact factor: 29.690

8.  Assessment of myocardial perfusion by harmonic power Doppler imaging at rest and during adenosine stress: comparison with (99m)Tc-sestamibi SPECT imaging.

Authors:  S K Heinle; J Noblin; P Goree-Best; A Mello; G Ravad; S Mull; P Mammen; P A Grayburn
Journal:  Circulation       Date:  2000-07-04       Impact factor: 29.690

9.  Long-term additive prognostic value of thallium-201 myocardial perfusion imaging over clinical and exercise stress test in low to intermediate risk patients : study in 1137 patients with 6-year follow-up.

Authors:  G Vanzetto; O Ormezzano; D Fagret; M Comet; B Denis; J Machecourt
Journal:  Circulation       Date:  1999-10-05       Impact factor: 29.690

10.  Noninvasive identification of acute myocardial ischemia and reperfusion with contrast ultrasound using intravenous perfluoropropane-exposed sonicated dextrose albumin.

Authors:  T R Porter; F Xie; A Kricsfeld; K Kilzer
Journal:  J Am Coll Cardiol       Date:  1995-07       Impact factor: 24.094

View more
  2 in total

1.  Effects of glucose-insulin-potassium infusion on chronic ischaemic left ventricular dysfunction.

Authors:  V K Khoury; B Haluska; J Prins; T H Marwick
Journal:  Heart       Date:  2003-01       Impact factor: 5.994

2.  Assessment of infarcted myocardium with real time myocardial contrast echocardiography: comparison with technetium-99m sestamibi single photon emission computed tomography.

Authors:  P Tousek; M Orban; S Martinoff; C Firschke
Journal:  Heart       Date:  2005-03-17       Impact factor: 5.994

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.