Literature DB >> 22847873

Assessment of modified gold surfaced titanium implants on skeletal fixation.

Kasra Zainali1, Gorm Danscher, Thomas Jakobsen, Jorgen Baas, Per Møller, Joan E Bechtold, Kjeld Soballe.   

Abstract

Noncemented implants are the primary choice for younger patients undergoing total hip replacements. However, the major concern in this group of patients regarding revision is the concern from wear particles, periimplant inflammation, and subsequently aseptic implant loosening. Macrophages have been shown to liberate gold ions through the process termed dissolucytosis. Furthermore, gold ions are known to act in an anti-inflammatory manner by inhibiting cellular NF-κB-DNA binding. The present study investigated whether partial coating of titanium implants could augment early osseointegration and increase mechanical fixation. Cylindrical porous coated Ti-6Al-4V implants partially coated with metallic gold were inserted in the proximal region of the humerus in ten canines and control implants without gold were inserted in contralateral humerus. Observation time was 4 weeks. Biomechanical push out tests and stereological histomorphometrical analyses showed no statistically significant differences in the two groups. The unchanged parameters are considered an improvement of the coating properties, as a previous complete gold-coated implant showed inferior mechanical fixation and reduced osseointegration compared to control titanium implants in a similar model. Since sufficient early mechanical fixation is achieved with this new coating, it is reasonable to investigate the implant further in long-term studies.
Copyright © 2012 Wiley Periodicals, Inc.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22847873      PMCID: PMC3693565          DOI: 10.1002/jbm.a.34307

Source DB:  PubMed          Journal:  J Biomed Mater Res A        ISSN: 1549-3296            Impact factor:   4.396


  32 in total

Review 1.  The pathology of total joint arthroplasty. I. Mechanisms of implant fixation.

Authors:  T W Bauer; J Schils
Journal:  Skeletal Radiol       Date:  1999-08       Impact factor: 2.199

Review 2.  Implant fixation by bone ingrowth.

Authors:  H Kienapfel; C Sprey; A Wilke; P Griss
Journal:  J Arthroplasty       Date:  1999-04       Impact factor: 4.757

3.  Structure of the interface between rabbit cortical bone and implants of gold, zirconium and titanium.

Authors:  P Thomsen; C Larsson; L E Ericson; L Sennerby; J Lausmaa; B Kasemo
Journal:  J Mater Sci Mater Med       Date:  1997-11       Impact factor: 3.896

Review 4.  Effects of dissolucytotic gold ions on recovering brain lesions.

Authors:  Gorm Danscher; Agnete Larsen
Journal:  Histochem Cell Biol       Date:  2010-03-17       Impact factor: 4.304

5.  Effect of topical alendronate treatment on fixation of implants inserted with bone compaction.

Authors:  Thomas Jakobsen; Søren Kold; Joan E Bechtold; Brian Elmengaard; Kjeld Søballe
Journal:  Clin Orthop Relat Res       Date:  2006-03       Impact factor: 4.176

6.  The influence of support conditions in the loading fixture on failure mechanisms in the push-out test: a finite element study.

Authors:  T P Harrigan; J Kareh; W H Harris
Journal:  J Orthop Res       Date:  1990-09       Impact factor: 3.494

7.  Radiostereometry of hip prostheses. Review of methodology and clinical results.

Authors:  J Kärrholm; P Herberts; P Hultmark; H Malchau; B Nivbrant; J Thanner
Journal:  Clin Orthop Relat Res       Date:  1997-11       Impact factor: 4.176

8.  Macrophage cell lines produce osteoinductive signals that include bone morphogenetic protein-2.

Authors:  C M Champagne; J Takebe; S Offenbacher; L F Cooper
Journal:  Bone       Date:  2002-01       Impact factor: 4.398

9.  Interspecies differences in bone composition, density, and quality: potential implications for in vivo bone research.

Authors:  J Aerssens; S Boonen; G Lowet; J Dequeker
Journal:  Endocrinology       Date:  1998-02       Impact factor: 4.736

Review 10.  Adjuvant therapies of bone graft around non-cemented experimental orthopedic implants stereological methods and experiments in dogs.

Authors:  Jørgen Baas
Journal:  Acta Orthop Suppl       Date:  2008-08
View more
  2 in total

Review 1.  Antimicrobial and Osseointegration Properties of Nanostructured Titanium Orthopaedic Implants.

Authors:  Marcus Jäger; Herbert P Jennissen; Florian Dittrich; Alfons Fischer; Hedda Luise Köhling
Journal:  Materials (Basel)       Date:  2017-11-13       Impact factor: 3.623

Review 2.  Nanoparticles and Nanostructured Surface Fabrication for Innovative Cranial and Maxillofacial Surgery.

Authors:  Simona Cavalu; Iulian Vasile Antoniac; Aurel Mohan; Florian Bodog; Cristian Doicin; Ileana Mates; Mihaela Ulmeanu; Roman Murzac; Augustin Semenescu
Journal:  Materials (Basel)       Date:  2020-11-27       Impact factor: 3.623