Literature DB >> 7743723

Acoustic noise levels generated during high field MR imaging.

M J McJury1.   

Abstract

Although much has been published highlighting the safety risks of magnetic resonance imaging, little mention has been made of acoustic noise levels. As the clinically available gradient strengths of MR systems increase, acoustic noise levels will become more important. Measurements were made of the acoustic noise levels generated by magnetic resonance imaging on two high field systems (1.0T and 1.5T). These data were compared with those in the literature. On the 1.0T magnetic resonance system, comparisons were also made between data acquired using the standard gradient system (maximum levels of 10m T/m) and a new upgraded gradient system (maximum levels of 15m T/m). The results show that many sequences produce noise levels above the safe levels defined by the Department of Health and the Health and Safety Executive. Providing routine ear protection for patients is, therefore, important. Noise levels for the upgraded gradient system on the 1.0T scanner are in the range of 2 dB greater. As expected, noise levels generated were greater for the 1.5T magnetic resonance imager than on the 1.0T system.

Entities:  

Mesh:

Year:  1995        PMID: 7743723     DOI: 10.1016/s0009-9260(05)83427-0

Source DB:  PubMed          Journal:  Clin Radiol        ISSN: 0009-9260            Impact factor:   2.350


  6 in total

1.  Acoustic noise during functional magnetic resonance imaging.

Authors:  M E Ravicz; J R Melcher; N Y Kiang
Journal:  J Acoust Soc Am       Date:  2000-10       Impact factor: 1.840

Review 2.  Acoustic noise concerns in functional magnetic resonance imaging.

Authors:  Adriaan Moelker; Peter M T Pattynama
Journal:  Hum Brain Mapp       Date:  2003-11       Impact factor: 5.038

3.  Characterization of vibration and acoustic noise in a gradient-coil insert.

Authors:  G Z Yao; C K Mechefske; B K Rutt
Journal:  MAGMA       Date:  2004-06-23       Impact factor: 2.310

4.  Assessing the influence of scanner background noise on auditory processing. I. An fMRI study comparing three experimental designs with varying degrees of scanner noise.

Authors:  Nadine Gaab; John D E Gabrieli; Gary H Glover
Journal:  Hum Brain Mapp       Date:  2007-08       Impact factor: 5.038

5.  Characterization of acoustic noise in a neonatal intensive care unit MRI system.

Authors:  Jean A Tkach; Yu Li; Ronald G Pratt; Kelly A Baroch; Wolfgang Loew; Barret R Daniels; Randy O Giaquinto; Stephanie L Merhar; Beth M Kline-Fath; Charles L Dumoulin
Journal:  Pediatr Radiol       Date:  2014-03-05

Review 6.  Safety challenges related to the use of sedation and general anesthesia in pediatric patients undergoing magnetic resonance imaging examinations.

Authors:  Maddy Artunduaga; C Amber Liu; Cara E Morin; Suraj D Serai; Unni Udayasankar; Mary-Louise C Greer; Michael S Gee
Journal:  Pediatr Radiol       Date:  2021-04-16
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.