Literature DB >> 7707921

Active acoustic screening: reduction of noise in gradient coils by Lorentz force balancing.

P Mansfield1, B L Chapman, R Bowtell, P Glover, R Coxon, P R Harvey.   

Abstract

We have designed and constructed a quiet gradient set with restricted access for the combined purposes of evaluating the principles of active acoustic screening, recently introduced by Mansfield, Glover, and Bowtell, and for EPI studies of the head at 3.0 T. The design utilizes the return paths of the conductors in a closed arc loop arrangement to eliminate net Lorentz forces thereby attenuating acoustic noise especially at low frequency. This design should significantly reduce the dangers to patients of high noise levels, especially in high field magnetic resonance imaging systems.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7707921     DOI: 10.1002/mrm.1910330220

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  10 in total

1.  Acoustic noise during functional magnetic resonance imaging.

Authors:  M E Ravicz; J R Melcher; N Y Kiang
Journal:  J Acoust Soc Am       Date:  2000-10       Impact factor: 1.840

Review 2.  Acoustic noise concerns in functional magnetic resonance imaging.

Authors:  Adriaan Moelker; Peter M T Pattynama
Journal:  Hum Brain Mapp       Date:  2003-11       Impact factor: 5.038

3.  A comprehensive experimental study of micro-perforated panel acoustic absorbers in MRI scanners.

Authors:  Gemin Li; Chris K Mechefske
Journal:  MAGMA       Date:  2010-05-13       Impact factor: 2.310

4.  Acoustic noise reduction in T 1- and proton-density-weighted turbo spin-echo imaging.

Authors:  Martin Ott; Martin Blaimer; Felix Breuer; David Grodzki; Björn Heismann; Peter Jakob
Journal:  MAGMA       Date:  2015-10-22       Impact factor: 2.310

5.  Acoustic noise reduction in a 4 T MRI scanner.

Authors:  Chris K Mechefske; Ryan Geris; Joseph S Gati; Brian K Rutt
Journal:  MAGMA       Date:  2002-01       Impact factor: 2.310

6.  Transverse gradient coil with circle current paths.

Authors:  E R Andrew; M Kempka
Journal:  MAGMA       Date:  1998-11       Impact factor: 2.310

Review 7.  Gradient and shim technologies for ultra high field MRI.

Authors:  Simone A Winkler; Franz Schmitt; Hermann Landes; Joshua de Bever; Trevor Wade; Andrew Alejski; Brian K Rutt
Journal:  Neuroimage       Date:  2016-11-30       Impact factor: 6.556

Review 8.  Applications in Awake Animal Magnetic Resonance Imaging.

Authors:  Craig F Ferris
Journal:  Front Neurosci       Date:  2022-04-05       Impact factor: 5.152

Review 9.  Toward 20 T magnetic resonance for human brain studies: opportunities for discovery and neuroscience rationale.

Authors:  Thomas F Budinger; Mark D Bird; Lucio Frydman; Joanna R Long; Thomas H Mareci; William D Rooney; Bruce Rosen; John F Schenck; Victor D Schepkin; A Dean Sherry; Daniel K Sodickson; Charles S Springer; Keith R Thulborn; Kamil Uğurbil; Lawrence L Wald
Journal:  MAGMA       Date:  2016-05-18       Impact factor: 2.310

10.  Reduced acoustic noise in diffusion tensor imaging on a compact MRI system.

Authors:  Ek T Tan; Christopher J Hardy; Yunhong Shu; Myung-Ho In; Arnaud Guidon; John Huston; Matt A Bernstein; Thomas K F Foo
Journal:  Magn Reson Med       Date:  2017-10-02       Impact factor: 4.668

  10 in total