We report the incidence of osteolysis in the femur, tibia, and patella of 44 consecutive patients (60 knees) who were followed for more than seven years after cementless knee arthroplasty with a Porous-Coated Anatomic prosthesis. The average age of the patients was 56.5 years (17 to 73); the operative diagnosis was osteoarthritis (33 knees), rheumatoid arthritis (17), tuberculous arthritis (7) and post-traumatic arthritis (3). All patellae were resurfaced. No femoral or tibial component was loose at the final follow-up examination. Thirty patellar components were loose of which six had been revised. Radiographs revealed osteolysis in 90% of the tibial plateaux and in 80% of the 30 intact patellar prostheses. No osteolysis was seen around any femoral component. In 50 knees (83%) the average wear of the polyethylene liner was 2.5 mm in the medial compartment and 1.7 mm in the lateral compartment. Four of 60 knees (6.7%) were revised for complete wear of the polyethylene liner of the tibial component. Fixation of the tibial and patellar components without cement fails to seal the interface between bone and prosthesis and allows the migration of polyethylene particulate debris which causes osteolysis.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7706337

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  10 in total

1.  Hybrid total knee arthroplasty: 13-year survivorship of AGC total knee systems with average 7 years followup.

Authors:  Philip M Faris; E Michael Keating; Alex Farris; John B Meding; Merrill A Ritter
Journal:  Clin Orthop Relat Res       Date:  2008-03-07       Impact factor: 4.176

2.  Osteolysis in well-functioning fixed- and mobile-bearing TKAs in younger patients.

Authors:  Young-Hoo Kim; Yoowang Choi; Jun-Shik Kim
Journal:  Clin Orthop Relat Res       Date:  2010-04-01       Impact factor: 4.176

3.  Is There A Difference in Bone Ingrowth in Modular Versus Monoblock Porous Tantalum Tibial Trays?

Authors:  Josa A Hanzlik; Judd S Day; Clare M Rimnac; Steven M Kurtz
Journal:  J Arthroplasty       Date:  2015-01-22       Impact factor: 4.757

4.  Highly Crosslinked-remelted versus Less-crosslinked Polyethylene in Posterior Cruciate-retaining TKAs in the Same Patients.

Authors:  Young-Hoo Kim; Jang-Won Park; Jun-Shik Kim; June-Hyung Lee
Journal:  Clin Orthop Relat Res       Date:  2015-06-27       Impact factor: 4.176

5.  Better survival of total knee replacement in patients older than 70 years: a prospective study with 8 to 12 years follow-up.

Authors:  Ricardo Fernandez-Fernandez; E Carlos Rodriguez-Merchan
Journal:  Arch Bone Jt Surg       Date:  2015-01-15

6.  Weight of polyethylene wear particles is similar in TKAs with oxidized zirconium and cobalt-chrome prostheses.

Authors:  Young-Hoo Kim; Jun-Shik Kim; Wansoo Huh; Kwang-Hoon Lee
Journal:  Clin Orthop Relat Res       Date:  2009-12-01       Impact factor: 4.176

7.  Long-term Results of Hybrid Total Knee Arthroplasty: Minimum 10-years Follow-up.

Authors:  Young Joon Choi; Ki Won Lee; Chung Hwan Kim; Hyung Sun Ahn; Jae Kwang Hwang; Jeong Ho Kang; Hee Don Han; Wan Jong Cho; Jun Seok Park
Journal:  Knee Surg Relat Res       Date:  2012-05-31

8.  Fixed or mobile-bearing total knee arthroplasty.

Authors:  Chun-Hsiung Huang; Jiann-Jong Liau; Cheng-Kung Cheng
Journal:  J Orthop Surg Res       Date:  2007-01-05       Impact factor: 2.359

9.  Bone Ongrowth of Contemporary Cementless Tibial Components: A Retrieval Analysis.

Authors:  Richard L Purcell; Elexis C Baral; Sean E Slaven; Timothy M Wright; Geoffrey H Westrich
Journal:  Arthroplast Today       Date:  2022-01-20

10.  Patient and surgery related factors associated with fatigue type polyethylene wear on 49 PCA and DURACON retrievals at autopsy and revision.

Authors:  Markus Rohrbach; Martin Lüem; Peter E Ochsner
Journal:  J Orthop Surg Res       Date:  2008-02-22       Impact factor: 2.359

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.